motionworks-iec-mcp-server
Click on "Deploy Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@motionworks-iec-mcp-server parse my MotionWorks IEC project export and list all POUs and variables"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
motionworks-iec-mcp-server
MCP server for Yaskawa MotionWorks IEC 3 — parse project exports and give AI agents structured access to POUs, variables, data types, tasks, I/O and motion configuration.
MotionWorks IEC has no AI tooling. Every other IEC 61131-3 environment has at least
an export story an agent can read; MotionWorks stores its code in a proprietary
compound binary (src.st1) and leaves you to read it in the IDE. This server
closes that gap by parsing the formats MotionWorks does export — and, because no
export defines the firmware motion library, by extracting that library's own
reference documentation from the MotionWorks installation.
What This Does
Connects AI agents (Claude, GPT, local LLMs) to a MotionWorks IEC project via the MCP Protocol. It reads three export forms and merges them:
Source | What it is | Best for |
PLCopen XML export ( | Standard IEC 61131-10 / TC6 export | Everything — all POUs, all languages, tasks, enumerated types |
Extended IEC 61131-2 export ( | Plain-text projection, one file per POU | Structured Text, |
Native project ( | What the IDE itself works with | The authoritative POU/task/dependency map, and |
Firmware library reference | The vendor's own help, installed with MotionWorks | What the motion blocks are — see below |
Plus the reference documentation for the firmware library, which is the difference between code that compiles and code that only looks plausible.
The three exports are complementary, not redundant, and each is incomplete in a
different way. Rather than pretend otherwise, the server merges them and reports
every disagreement via get_sources, so you can see when an export is stale or
partial. Concretely, in the sample projects shipped with this repo:
TopCutter.xmlomitsTopCutterCutControl,TopCutterCamSetupandTopCutterFFCamSetup, which the Extended export has.StraightCutappears only in the XML.TopCutter.xmlships an empty<ST>body forStraightCut,CamGenandInitialize; the Extended export has their real source.The native project declares 10 programs and 5 function blocks the exports do not all mention.
For
MC_Directionthe export lists five values and the vendor help documents four —Bothis accepted by the firmware but undocumented in that help version.
The firmware library reference
No MotionWorks export defines MC_Power. The XML references it by name and never
says what it takes. So the agent cannot know that it has ten parameters, which
three of them do nothing on this firmware, or what BufferMode accepts.
The reference exists on disk. MotionWorks installs each library's documentation as compiled help, and Windows can decompile it:
C:\ProgramData\Yaskawa\MotionWorks IEC 3 Pro\<version>\plc\FW_LIB\<lib>\*.chm
hh.exe -decompile <dir> <chm> # driven via PowerShell Start-ProcessThe server does this lazily, once, into a local cache, and parses the pages into a structured catalog. Against the installed 3.7.5.1 reference that is 110 function blocks, 41 data types and 45 enumerated values — parameter names, scopes, data types, defaults, per-parameter descriptions, unimplemented-pin flags, block purpose, notes, related blocks and usage examples.
Nothing of Yaskawa's is copied into this repository: the extraction goes to
%LOCALAPPDATA%\motionworks-iec-mcp\fwlib\ and the vendor content stays where
Yaskawa installed it. Cold extraction plus parse takes about 1.4 s; afterwards it
is ~10 ms from a cached catalog.
Smart Chunking
A ladder or FBD body in the XML export is thousands of lines of coordinate geometry. This server collapses each network to one line naming every block, instance and formal parameter — the equivalent of NeutralText for Studio 5000:
MC_Power(MC_TopCutter_ServoOn) Enable=EIP_FromCLX_Axis_SVON_Cmd Axis=TopCutter
MC_Reset(MC_TopCutter_Reset) Execute=EIP_FromCLX_Axis_FaultReset Axis=TopCutter
MC_ReadStatus(MC_TopCutter_ReadStatus) Enable=Always_True Axis=TopCutterStructured Text is returned as the original source, tab alignment and inline comments intact.
Related MCP server: io.github.purinzan/gx3-cli-mcp
Installation
Install straight from the repository — no clone needed:
python -m venv .venv
.venv/Scripts/python -m pip install "git+https://github.com/KphungFROMM/motionworks-iec-mcp-server.git"Or clone first, if you intend to modify it:
git clone https://github.com/KphungFROMM/motionworks-iec-mcp-server.git
cd motionworks-iec-mcp-server
python -m venv .venv
.venv/Scripts/python -m pip install -e .pip install -e ".[dev]" additionally installs pytest, for running the suite.
Requires Python 3.10+. The firmware library reference additionally needs Windows
with hh.exe and PowerShell; without them everything else still works and library
signatures fall back to what the project itself reveals.
It has to run locally. MCP over stdio works by the client spawning a process, so
the client needs a program on disk — a git URL changes how that program gets
installed, not whether it is local. And it is moot here anyway: the server reads your
MotionWorks exports and the firmware reference from the machine it runs on, so it
belongs on the PC with MotionWorks installed. See
WORKFLOW.md §1 for the reasoning, and for running it
from a URL with uvx.
Quick Start
stdio (local — Claude Desktop, Claude Code, DSH, kiro-cli)
motionworks-iec-mcp-serverSSE (remote)
motionworks-iec-mcp-server --transport sse --host 127.0.0.1 --port 8080Configuration
Claude Desktop / generic MCP client
{
"mcpServers": {
"motionworks": {
"command": "C:/path/to/motionworks-iec-mcp-server/.venv/Scripts/motionworks-iec-mcp-server.exe",
"args": []
}
}
}Agent harnesses: use the launcher
If your client is an agent harness that may set PYTHONHOME for its own bundled
Python, point it at the launcher instead — a venv python.exe inheriting an invalid
PYTHONHOME dies during interpreter startup, before any of this code runs, and the
client just reports a server that will not connect:
{
"mcpServers": {
"motionworks": {
"command": "C:/path/to/motionworks-iec-mcp-server/scripts/motionworks-iec-mcp-server.cmd",
"args": []
}
}
}The launcher clears PYTHONHOME, PYTHONPATH and PYTHONSTARTUP and then runs the
same server. Measured under a hostile PYTHONHOME: the bare .exe returns no
response, the launcher returns 28 tools. WORKFLOW.md has the
field-by-field version for GUI clients that ask for command/arguments/environment
separately.
Environment variables
Variable | Purpose |
| The |
| Where extraction and the parsed catalog are cached. |
| Only used by the test suite, to point at real exports. |
Installing into a project-local venv
python -m venv .venv
.venv/Scripts/python -m pip install -e .Then point the client at .venv/Scripts/motionworks-iec-mcp-server.exe.
Available Tools
ping
Health check. Returns "pong".
open_project(path)
Start here. Detects the source form, merges every export present, and returns
the project summary including a divergences list. path may be a PLCopen XML
file, an Extended export directory, or a native project directory.
load_project(plcopen_xml_path)
Parse a PLCopen XML export specifically. Kept for parity with the studio5000
connector; open_project supersedes it.
get_sources(path)
Which export forms exist, what each supplied (POUs with code, languages), what the counts are, and exactly where the sources disagree. Use this whenever a tool returns less than you expected.
get_tags(path, scope?, data_type?, address?, search?)
Every variable in the project — global variables with their AT % addresses and
comments, plus each POU's declared interface.
get_tags(path, data_type="AXIS_REF")
get_tags(path, address="%MX1.7") # what lives at this bit?
get_tags(path, search="PLCMODE")get_tag(path, tag_name)
One variable: its declaration(s), its type's members, and every place it is used across POUs, networks and lines.
get_types(path, search?, kind?, limit?)
Data types, structs, enums and function blocks. This is the vocabulary code must
be written against — including the Yaskawa motion library (AXIS_REF,
Y_ENGAGE_DATA, MC_*, Y_*, AxisControl) that only the PLCopen XML export
carries.
get_type(path, type_name?, search?)
A type definition with its members, types and comments.
get_udts(path) / get_udt(path, udt_name?)
Project-defined types only, excluding the vendor library.
get_fb_signature(path, fb_name)
A function block's interface, combining two authorities because each knows something the other does not:
the project knows the exact pin list its firmware build compiled against (from
.DITmetadata) or what the code actually passes;the firmware reference knows data types, defaults, per-pin meaning, which pins this firmware leaves unimplemented, the block's purpose and an example.
Pins the project never mentioned are still listed, so a block can be called with
parameters it has never been called with here. unsupportedPins names parameters
that exist but do nothing. A disagreement about a pin's type keeps both, as type
and projectType.
get_fb_signature(path, "MC_MoveAbsolute")
→ 15 pins, e.g.
inOut Axis AXIS_REF ("Logical axis reference…")
input Position LREAL default LREAL#0.0
input Direction MC_Direction default MC_Direction#1
input BufferMode MC_BufferMode
output Done BOOLlist_library_blocks(search?, library?, limit?)
Every function block the firmware provides — device documentation, not project state, so it works without opening a project and includes blocks the project never uses. Use it to find out what is available before writing code.
search_library(query, limit?)
Search the reference by block name, formal parameter, type name, description, notes or example code. Answers "which block do I use for X?".
search_library("torque") → MC_TorqueControl, MC_ReadActualTorque, Y_ControlMode…
search_library("cam") → Y_CamIn, Y_CamOut, Y_CamScale, Y_CamShift…get_library_reference_status()
Whether the reference is available, which libraries it found, what the cache holds, and — when it is not available — exactly how to enable it.
get_code_conventions(path)
Call this before generating code. Conventions are written down nowhere; they are visible only in the existing symbols, and code that compiles but breaks them reads as foreign in review. Each rule carries its evidence and a confidence, so a weak signal is not mistaken for a house standard.
get_code_conventions(path)
→ "x" names boolean variables (BOOL) [strong, 120 uses]
"i" names integer variables (INT) [strong, 44 uses]
"r" names real variables (LREAL) [strong, 31 uses]
function-block instances are prefixed with the block family and purpose
"EIP_ToCLX_*" is an established signal family (89 variables)
tasks run in priority order FastTsk(T#4ms), MedTsk(T#20ms)…
body languages in use: ST×4, LD×3
namingSummary: {boolean: x, integer: i, real: r}get_pous(path, language?, task?, search?)
Programs and function blocks with language, assigned task and size.
get_pou(path, pou_name, offset?, include_interface?, include_outputs?)
The workhorse. One POU's interface, its body, and every network it contains.
Structured Text comes back verbatim; LD/FBD comes back as one text line per
network plus a structured nets array. Long bodies page via offset and report
truncated/nextOffset.
{
"name": "ServoTaskSlow", "language": "LD", "task": "SlowTsk",
"interface": { "VAR_EXTERNAL": [{"name": "TopCutter", "type": "AXIS_REF",
"comment": "SGD7S - 1 (Do Not Modify!!)"}] },
"body": { "networkCount": 5, "code": "MC_Power(MC_TopCutter_ServoOn) ...",
"nets": [{"number": 0, "nodes": [{"kind":"block","type":"MC_Power",
"instance":"MC_TopCutter_ServoOn",
"params":{"Enable":"EIP_FromCLX_Axis_SVON_Cmd","Axis":"TopCutter"}}]}] }
}get_routines(path, program?) / get_routine(path, program, routine_name?)
Aliases for get_pous / get_pou so the studio5000 calling convention works.
get_tasks(path)
Controller tasks with type, interval, priority, watchdog and the programs each runs. Task assignment decides execution order — check it before assuming two POUs run in sequence.
get_io_config(path)
Named I/O groups with address ranges, drivers and data types, which is how the
AT %I/%Q variables get their physical meaning.
get_motion_config(path)
The motion picture: every axis reference, the <axis>.AxisNum := N; bindings
found in startup code, the servo/network groups from the I/O configuration, and
the motion types available. Answers "which servo is axis 1?".
search_logic(path, pattern, limit?)
Where is this symbol used / which routines call this block? Matches the symbol
table (declarations, block types, instances, pins) first, then raw ST lines.
Regex supported — note the pattern is a plain regex, so MC_ matches every
MC_* block reference.
search_logic(path, "TopCutter_Homed")
search_logic(path, "MC_") # every MC_* block reference
search_logic(path, "Y_Cam(In|Out)") # either cam blockvalidate_pou(path, code, declared_vars?, pou_name?)
Validate generated code against the project's real symbols. Catches the mistakes an LLM actually makes, before the user sees them:
undeclared_tag— a symbol the project does not declare anywhereunknown_type— a declaration using a type the project does not haveunknown_pin— a formal parameter the target FB does not defineduplicate_declaration— the same variable declared twice in one scope
Identifier comparison is case-insensitive, because IEC 61131-3 identifiers are
— the RK_DemoOnMP3300iec sample declares Products and compiles products. A
case-sensitive check would report that legal code as undeclared. A casing
difference from the declaration is surfaced as an identifier_case style warning
instead, and caseVariants lists them.
Pin names are checked against the project's own block definitions where it has them, and against the firmware reference otherwise — which matters because an Extended-only project carries no type definitions at all, so without it the pin check would silently do nothing for exactly the projects that need it.
A native project looks like the real thing and is the most natural path to point at,
but its code is a compound binary. So when a source is missing, open_project and
get_sources return an exportGuidance block rather than a hollow result: what is
missing, what it costs, the verified export steps, and — if exports exist elsewhere on
disk — the path to the one matching this project. An agent handed a bare .mwt can
therefore tell you what to do instead of guessing at code it cannot see.
Situation |
| Consequence |
native project only |
| nothing readable — no source, variables or types |
Extended export only |
| no type definitions, so no block interfaces; 16 % graphical pin recovery |
PLCopen XML only |
| no I/O configuration, task names or |
render_pou_source(name, pou_type?, language?, declaration?, code?, description?)
Emit a POU in the shape MotionWorks' Extended IEC 61131-2 export uses — the
(*@PROPERTIES_EX@ ... *) header, the PROGRAM/FUNCTION_BLOCK line, declaration
blocks and the (*@KEY@: WORKSHEET ... *) body region.
This output parses back through this server, so its structure matches the export
format. Whether the IDE imports that shape is not verified — that format is
undocumented in the installed help, whose documented import path is PLCopen XML
(File → Import). So either create a POU in the IDE and paste the code, or wrap
the result in PLCopen XML for the documented route. See
WORKFLOW.md §5.
render_type_source(name, members?, comment?)
Emit a TYPE ... END_STRUCT END_TYPE definition in the same shape, with the same
caveat about import.
list_languages()
Which IEC body languages are rendered, from which source, and how completely.
Workflow
WORKFLOW.md is the end-to-end guide: install, the exact IDE export steps (quoted from MotionWorks' own help), which artifacts to point at, example prompts, and how generated code gets back into the project.
The short version:
Install the server and add it to your MCP client.
Export from MotionWorks —
File→Export→ "Export PLCopen xml file", saved as V1.01. The XML export deliberately excludes I/O configuration (the vendor help says so), so also produce the Extended IEC 61131-2 export.Point the agent at one project's artifacts. It merges them and reports where they disagree — read that list, it is often the most important thing about a project.
Work in the loop: ask → the agent looks up real symbols, conventions and block signatures → generates → validates against the project → emits a file.
Get it back in by pasting into a new POU, or via
File→Import→ "Import PLCopen xml file" (the documented path).
flowchart LR
A[MotionWorks project] -->|File - Export| B[PLCopen XML]
A -->|Extended IEC 61131-2| C[ST / GVB / EIO / EXP]
A -.->|optional| D[native folder<br/>POU index + .DIT]
B --> E[open_project<br/>merge + divergences]
C --> E
D --> E
E --> F[get_tags / get_pou / search_logic]
E --> G[get_fb_signature / search_library]
E --> H[get_code_conventions]
F --> I[generate]
G --> I
H --> I
I --> J[validate_pou]
J -->|errors| I
J -->|ok| K[render_pou_source]
K --> L[File - Import, or paste into a new POU]Example conversation
You: Open the TopCutter project and tell me what it does.
Agent calls: open_project("C:/projects/PLCOpen XML Export/TopCutter.xml")
open_project("C:/projects/Extended IEC 61131-2 Export/TopCutter")
Agent: Both merged — 10 POUs, 281 variables, 7 tasks, processor MP2600iec.
Divergence warnings: the XML export omits TopCutterCutControl, TopCutterCamSetup
and TopCutterFFCamSetup, while it is the only source for StraightCut, CamGen and
Initialize — and it ships an empty body for two POUs the Extended export has real
source for, which is what I used. Named tasks are FastTsk (T#4ms, priority 0),
MedTsk (T#20ms, 3), SlowTsk (T#100ms, 7), plus BG and Start with no interval.
CamGen and Initialize run in tasks the named export does not describe — priority 10
/ 1 s and priority 0 / WarmStart — so those are reported by schedule instead of name.
You: What drives TopCutter_Homed and who reads it?
Agent calls: get_tag(project, "TopCutter_Homed")
Agent: A global BOOL, "Top Cutter Axis is Homed". Written in ServoHoming (LD) and
read in four places: TopCutterCutControl (ST), EIP_ToCLX (LD, feeding
EIP_ToCLX_Axis_Homed) and ServoTaskSlow. Gated on PLCMODE_RUN.
You: Add a POU that reads the top cutter position and scales it.
Agent calls: get_code_conventions(project)
get_fb_signature(project, "MC_ReadActualPosition")
validate_pou(project, "<generated code>")
Agent: This project uses x/i/r prefixes and MC_<Thing>_<Action> instance names, so
I named things accordingly. MC_ReadActualPosition takes Axis (AXIS_REF),
Enable (BOOL), Valid/Busy/Error (BOOL), ErrorID (UINT), Position (LREAL).
Validated against the project: 0 errors. Here's TopCutterPosition.ST.Every claim there comes from a tool result rather than the agent's recollection, which is the point. See WORKFLOW.md for the full worked example.
Design Constraints Worth Knowing
Graphical logic is authoritative in the PLCopen XML export. The same logic recovered from an Extended export's
.GEfile is partial by design: the format is undocumented, and the ordinal/pin mapping that would recover it fully does not round-trip reliably. So the.GEdecoder reports block structure, pins and parameter names exactly (verified against the XML for the same programs) and recovers pin values only where it is provably safe — currently 100 % precise, 16 % recall on the sample set, with the unmatched count reported rather than guessed.list_languagesstates this at runtime.Merged projects pick the body per language, not per file. Structured Text comes from the plain-text Extended export (original tab alignment); LD/FBD comes from the PLCopen XML (real connections, complete pin values). Which export a body came from is reported as
body.source, separately from the POU's ownsourcewhich names the record that supplied its metadata.Task merging is exact, and refuses to guess. The PLCopen XML export carries no task names, so its tasks arrive as
task@<priority>@<interval>and are matched to named tasks by priority and normalised interval — the two exports write intervals differently (00:00:00.20andT#20msare both 20 ms, and the first is not a decimal fraction of a second). Matching on any overlap of program lists was tried and removed: when two exports describe different generations of a project, a partial overlap silently welds programs onto the wrong task. A program-list disagreement is reported astask_program_conflictand the named export wins; a task that cannot be matched keeps its provisional@name, because a known schedule with an unknown name is more useful than a guess.The native project cannot supply code.
src.st1,TREE.XMLand.IOCare compound binary. What it does provide is the authoritative POU/task/dependency map fromeCLRPouDependencies.dat, plus the.DITfunction-block interfaces described above.No live controller connection. MotionWorks IEC exposes no documented programmatic interface, so this server is export-based, like the studio5000 connector. Re-export from the IDE to refresh.
Read and generate, not write-back. Generated code is emitted to a file for import. This server will not write into a
.mwtproject: the format is undocumented binary, and a bad write could corrupt a live machine project.
Known Gaps
Stated plainly, because the difference between "plausible code" and "code that compiles" lives here.
Graphical wiring recovered from a
.GE-only project is partial. If the PLCopen XML export is unavailable, the.GEdecoder reports block structure, pin names and parameter names exactly but recovers only 16 % of pin values (100 % precise — it never reports a wrong one). Re-export as PLCopen XML when you can.The reference documents one firmware version. The catalog is keyed to the installed MotionWorks version. Values and support flags differ between versions, so a project built against a different firmware release may see pins marked supported here that are not, or vice versa.
get_library_reference_statusreports which version was read.Project-generated
.DITinterfaces can disagree with the reference about a pin's underlying type (the export recordsINTwhere the block declaresMC_BufferMode). Both are reported rather than one being discarded, but the reference is preferred for the declared type.No write-back into the IDE, and the import path for generated text is unverified.
render_pou_sourceemits the shape the Extended IEC 61131-2 export uses, which this server parses back — but whether the IDE imports that shape is not documented in the installed help, whose documented import path is PLCopen XML. Until a PLCopen XML emitter exists, useFile→Import→ "Import PLCopen xml file" with your own wrapper, or create a POU in the IDE and paste the code (always works). Writing into a.mwtis deliberately not attempted: it is undocumented binary and a bad write could corrupt a live machine project.No live controller connection. MotionWorks IEC exposes no documented programmatic interface, so this server is export-based, like the studio5000 connector. Re-export from the IDE to refresh.
Project Structure
src/motionworks_iec_mcp_server/
├── __main__.py # CLI entry point (stdio / SSE)
├── server.py # FastMCP app — 28 tool definitions
├── project.py # source detection, merge, divergence reporting
├── model.py # the normalized project model
├── fwlib.py # firmware library reference: extract, parse, cache, merge
├── cache.py # mtime-keyed parse cache
├── util.py # tolerant file reading, IEC text handling
├── codegen/
│ ├── validate.py # code validation + MotionWorks file emission
│ └── conventions.py # observed house conventions
└── parsers/
├── plcopen_xml.py # authoritative: POUs, types, tasks, all languages
├── extended_iec.py # text POUs, global vars, I/O config, task names
├── native.py # NODES.LST, POU index, .DIT + TYLLIST interfaces
├── graphical.py # .GE decoder + PLCopen LD/FBD renderer
├── st.py # declaration blocks, POU headers, ST splitting
└── xref.py # symbol → usage index
tests/ # pytest suite (283 tests)
WORKFLOW.md # install → export → work → import, end to end
FORMATS.md # the formats, documented from real filesDevelopment
python -m venv .venv
.venv/Scripts/python -m pip install -e ".[dev]"
.venv/Scripts/python -m pytest tests/ -vTests are hermetic by default. Integration tests additionally run against real
exports when MOTIONWORKS_SAMPLES points at a folder containing them, and tests
for the shipped reference pages run against a synthetic tree shaped like the real
one — with a further set that runs against the actual installation when present:
MOTIONWORKS_SAMPLES="C:/Users/me/Desktop/MotionWorks IEC MCP" \
.venv/Scripts/python -m pytest tests/ -vDependencies
fastmcp is the only runtime dependency; every parser uses the standard library
(xml.etree.ElementTree, re, json, dataclasses). That is deliberate — this
runs next to industrial machinery, and fewer moving parts is better. The claim is
enforced by tests/test_dependencies.py, which walks the AST of every module under
src/ and fails if a third-party import appears that pyproject.toml does not
declare.
Roadmap
v0.1 — Parsing and comprehension ✅
PLCopen XML parser: POUs, all languages, tasks, globals, enumerated types
Extended IEC parser: ST/GE/IEC, GVB with addresses, EIO, EXP task config
Native parser: project tree, POU/task dependency index,
.DITinterfacesSource detection, merge and divergence reporting
LD/FBD rendering to per-network text (XML full,
.GEpartial by design)Cross-reference index and search
Code validation against project symbols
MotionWorks file emission for import (POU and TYPE)
v0.2 — Complete library knowledge ✅
Firmware library reference: locate, decompile, parse, cache
110 function blocks with pin scope, type, default, description and support flags
41 data types and 45 enumerated values from the vendor's own help
Merge reference with project
.DITand observed call siteslist_library_blocks,search_library,get_library_reference_statusObserved-convention analysis (
get_code_conventions)
v0.3 — Close the round trip
PLCopen XML emitter for generated POUs and data types, so output uses the import path the vendor actually documents (
File→Import→ "Import PLCopen xml file") rather than the Extended text shape, which is unverified for import
v0.4 — Deeper graphical fidelity
Complete
.GEpin-value recovery (needs a documented ordinal contract)SFC bodies, if any export ever emits them
Alarm and cam-table extraction from the reference
v0.5 — Project write-back
Write POUs into an Extended export layout
Optional
.mwtwrite-back once the container format is understood
License
MIT — see LICENSE.
Available Tools
28 toolsget_code_conventionsA
Report the coding conventions this project already follows.
Call this before generating code. Conventions are written down nowhere — they are visible only in the existing symbols — and code that compiles but breaks them reads as foreign in review. Each rule carries the evidence behind it and a confidence, so a weak signal is not mistaken for a house standard.
Covers: variable name prefixes by type (x→BOOL, r→LREAL, udi→UDINT),
function-block instance naming, established signal families, documentation
habits, task structure and the languages in use.
Args: path: Project file or directory.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
get_fb_signatureA
Get a function block's interface — for calling or instancing it correctly.
Combines two authorities, because each knows something the other does not:
the project knows the exact pin list its firmware build compiled against (from
.DITmetadata) or what the code actually passes;the firmware library reference knows data types, defaults, per-pin meaning, which pins this firmware leaves unimplemented, the block's purpose, and a usage example.
Pins the project does not mention are still listed, so a block can be called
with parameters it has never been called with here. unsupportedPins names
parameters that exist on the block but do nothing on this firmware.
Args: path: Project file or directory. fb_name: Function block name, e.g. "MC_Power", "Y_CamIn", "AxisControl".
Inputs: path (required), fb_name (required). Returns: Generic wrapper for non-object return types.
get_io_configA
List the controller and network I/O configuration.
Each entry is a named I/O group mapped to an address range and a driver, which
is how the AT %I/%Q variables in the global variable table get their
physical meaning.
Args: path: Project file or directory.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
get_library_reference_statusA
Report whether the firmware library reference is available, and how to enable it.
The reference is the vendor's own help, installed with MotionWorks and decompiled locally. It is what makes the motion library's parameters, types and semantics knowable. If this reports it is unavailable, that is the reason library signatures fall back to observed usage.
Inputs: no named parameters. Returns: Generic wrapper for non-object return types.
get_motion_configA
Summarise the motion setup: axes, their amplifier bindings and network nodes.
MotionWorks binds an axis to hardware through <var>.AxisNum assignments in
startup code (e.g. TopCutter.AxisNum := UINT#1;) and the servo groups in
the I/O configuration (SGD7S Network #1 Node #1). This tool joins those two
so "which servo is axis 1?" is answerable.
Args: path: Project file or directory.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
get_pouA
Get one POU: its interface, its body, and every network it contains.
This is the workhorse tool. Structured Text is returned as the original
source, tab alignment and inline comments intact. Ladder and FBD bodies are
returned as one compact text line per network plus a structured nets array
naming each block, its instance and each formal parameter's source — the
equivalent of NeutralText for Studio 5000, and far smaller than the raw XML.
Long bodies are paged: check body.truncated and pass offset to
continue.
Args:
path: Project file or directory.
pou_name: POU name exactly as reported by get_pous.
offset: Line offset into the body, for paging long POUs.
include_interface: Include the declared variables for each scope.
include_outputs: For graphical bodies, include each block's output pins.
Inputs: path (required), pou_name (required), offset, include_outputs, +1 more. Returns: Generic wrapper for non-object return types.
get_pousA
List programs and function blocks with language, task and size.
Args: path: Project file or directory. language: Filter by body language: "ST", "LD", "FBD". task: Filter by the task the program runs under, e.g. "FastTsk". search: Case-insensitive substring filter on the POU name.
Inputs: path (required), task, search, language. Returns: Generic wrapper for non-object return types.
get_routineA
Get a POU's body (alias for get_pou, for familiarity with studio5000).
Args: path: Project file or directory. program: POU name. routine_name: Ignored; present so the studio5000 calling convention works.
Inputs: path (required), program (required), routine_name. Returns: Generic wrapper for non-object return types.
get_routinesC
List POUs (alias for get_pous, for familiarity with studio5000).
Args: path: Project file or directory. program: Filter by POU name.
Inputs: path (required), program. Returns: Generic wrapper for non-object return types.
get_sourcesA
Report which export forms exist for a project and what each contributes.
Use this when a tool returns less than you expected: it says which sources are
readable, what each one supplied, and exactly where they disagree. When a source
is missing — including the common case of a native project with no export beside
it — the response carries an exportGuidance block with the steps to produce
it, taken from MotionWorks' own help.
Args: path: File or directory to inspect.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
get_tagA
Get one variable's full detail plus every place it is used.
Use this to answer "what is this signal and what drives it?" — it returns the declaration (with address and comment) alongside every POU, net and line that references it.
Args: path: Project file or directory. tag_name: Variable name. A qualified name such as "Products.Sensor.Bit" also works.
Inputs: path (required), tag_name (required). Returns: Generic wrapper for non-object return types.
get_tagsA
List project variables (the MotionWorks equivalent of tags).
Combines global variables (which carry AT % addresses) with every POU's
declared interface variables, so this is the full symbol surface of the
project.
Args: path: Project file or directory. scope: Filter by scope, e.g. "VAR_GLOBAL", "VAR_EXTERNAL", "VAR", "VAR_INPUT". data_type: Filter by data type, e.g. "BOOL", "LREAL", "AXIS_REF". address: Substring filter on the AT address, e.g. "%MX1.7" . search: Case-insensitive substring filter on the variable name.
Inputs: path (required), scope, search, address, +1 more. Returns: Generic wrapper for non-object return types.
get_tasksA
List controller tasks with timing and the programs each one runs.
Task assignment decides execution order and jitter, so check this before assuming code in two POUs runs in a particular sequence.
Args: path: Project file or directory.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
get_typeA
Get a type definition with its members.
Use get_fb_signature instead when you want a function block's pin table in
a form oriented around calling it.
Args:
path: Project file or directory.
type_name: Exact type name. Empty returns every type that matches search,
or all types when search is empty too.
search: Case-insensitive substring filter, used when type_name is empty.
Inputs: path (required), search, type_name. Returns: Generic wrapper for non-object return types.
get_typesA
List data types, structs and function blocks available in the project.
This is the vocabulary an agent must code against — including the Yaskawa
motion library (AXIS_REF, Y_ENGAGE_DATA, MC_*, Y_*,
AxisControl) when the PLCopen XML export is present, which it is the only
source that carries.
Args: path: Project file or directory. search: Case-insensitive substring filter on the type name. kind: Filter by kind: "struct", "enum", "array", "alias" or "fb". limit: Maximum number of types to return.
Inputs: path (required), kind, limit, search. Returns: Generic wrapper for non-object return types.
get_udtA
Get a user-defined type definition with its members.
Args: path: Project file or directory. udt_name: Type name. Empty returns all project-defined types.
Inputs: path (required), udt_name. Returns: Generic wrapper for non-object return types.
get_udtsA
List user-defined types only (project-defined, excluding the vendor library).
Args: path: Project file or directory.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
list_fb_catalogA
List every function block the project uses, with the parameters it passes.
This is the practical coding vocabulary: the blocks that are actually available in this machine and the formal parameter names they are actually called with. The vendor library is not exported as type definitions, so this is the only complete view of it for a given project.
Args: path: Project file or directory. search: Case-insensitive substring filter on the block name.
Inputs: path (required), search. Returns: Generic wrapper for non-object return types.
list_languagesA
Report which IEC body languages this server can render, and how well.
Useful context for interpreting results: graphical bodies from the PLCopen XML
export are complete, whereas the same logic recovered from an Extended export's
.GE file is partial by design (see the server README).
Inputs: no named parameters. Returns: Generic wrapper for non-object return types.
list_library_blocksA
List the function blocks the MotionWorks firmware library provides.
This is device documentation, not project state: it works without opening a project, and it includes blocks this project never uses. Use it to find out what is available before writing code.
Args: search: Case-insensitive substring filter on the block name. library: Filter by library, e.g. "YMotion" or "PLCopen". limit: Maximum number of blocks to return.
Inputs: limit, search, library. Returns: Generic wrapper for non-object return types.
load_projectA
Parse a PLCopen XML export and return a project summary.
Kept for parity with the studio5000 connector. open_project is preferred
because it also finds the Extended and native sources.
Args: plcopen_xml_path: Path to a PLCopen XML file exported from MotionWorks IEC.
Inputs: plcopen_xml_path (required). Returns: Generic wrapper for non-object return types.
open_projectA
Open a MotionWorks IEC project, merging every export form present.
This is the entry point for every other tool. path may be a PLCopen XML
file, an Extended IEC 61131-2 export directory, or a native project
directory — the source is detected, not declared.
Returns the project summary plus a divergences list. Read that list: the
exports are incomplete in different ways (an XML export can omit POUs that
the Extended export has, or ship them with an empty body), so a divergence is
often the most important thing about a project.
If you passed a native project (.mwt) with no export beside it, the
response also carries an exportGuidance block. Its code lives in a compound
binary, so no source, variables, types or I/O can be read. The block says exactly
what is missing, what that costs you, the verbatim steps to produce each export,
and — if exports exist elsewhere on disk — the path to the one matching this
project. Relay those steps to the user rather than guessing at the code.
Args: path: File or directory to open.
Inputs: path (required). Returns: Generic wrapper for non-object return types.
pingA
Health check — verify the server is running.
Inputs: no named parameters. Returns: Generic wrapper for non-object return types.
render_pou_sourceA
Emit a POU in the shape MotionWorks' Extended IEC 61131-2 export uses.
Produces the (*@PROPERTIES_EX@ ... *) header, the PROGRAM/FUNCTION_BLOCK
line, the declaration blocks and the (*@KEY@: WORKSHEET ... *) body region —
the same structure the IDE writes when exporting a POU as text.
Whether the IDE imports this shape is not verified: that format is
undocumented in the installed help, whose documented import path is PLCopen XML
(File → Import → "Import PLCopen xml file"). So either create a POU in
the IDE and paste the code, or wrap the result in PLCopen XML for the documented
route.
Args: name: POU name. pou_type: "program", "function_block" or "function". language: Body language — "ST", "LD" or "FBD". declaration: The VAR blocks, without the closing END_* keyword. code: The Structured Text body. description: Free text stored in the POU's DESCRIPTION region.
Inputs: name (required), code, language, pou_type, +2 more. Returns: Generic wrapper for non-object return types.
render_type_sourceA
Emit a TYPE ... END_TYPE struct definition in MotionWorks' text shape.
Same caveat as render_pou_source: the structure matches what the IDE
exports, but the documented import path is PLCopen XML.
Args:
name: Type name.
members: List of objects like {"name": "PartLength", "type": "LREAL", "comment": "mm"}.
comment: Optional description stored in the DESCRIPTION region.
Inputs: name (required), comment, members. Returns: Generic wrapper for non-object return types.
search_libraryA
Search the firmware library by block name, pin name, type or description.
Answers "which block do I use for X?" — searching names, formal parameters, descriptions, notes and example code, plus enumerated types and their values.
Args: query: Text to look for, e.g. "torque", "cam in", "BufferMode", "alarm". limit: Maximum number of matches.
Inputs: query (required), limit. Returns: Generic wrapper for non-object return types.
search_logicA
Search for a tag, block or regex across every POU and network.
Answers "where is this used?" and "which routines call this block?". Matches symbol-table entries (declarations, block types, instances, pins) first, then raw Structured Text lines, so both a tag name and a regex work.
Note the pattern is an ordinary regex, so MC_ matches every MC_*
block reference (the underscore is literal, and MC_\d+ would require
digits after it and so match nothing).
Args: path: Project file or directory. pattern: Tag name, block name, or regex pattern. limit: Maximum number of matches to return.
Inputs: path (required), pattern (required), limit. Returns: Generic wrapper for non-object return types.
validate_pouA
Validate agent-written IEC code against the project's real symbols.
Call this on generated code before handing it to a user. It catches the mistakes an LLM actually makes: tags that do not exist in the project, types that are not defined, function blocks that are not in the library, and formal parameter names that the target block does not have.
Args: path: Project file or directory. code: The Structured Text body to check (no declaration blocks). declared_vars: Any VAR blocks the code relies on, so locally declared symbols are not reported as undeclared. pou_name: Optional name, used only for labelling the result.
Inputs: code (required), path (required), pou_name, declared_vars. Returns: Generic wrapper for non-object return types.
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
TDQS
Scored across 28 tools
Descriptions are unusually thorough and cross-reference each other (e.g. get_type pointing to get_fb_signature), which aids selection. However there is real overlap: get_routines/get_pous and get_routine/get_pou are deliberate aliases, and get_types/get_type/get_udts/get_udt/get_fb_signature/list_fb_catalog/list_library_blocks form a dense cluster of type-and-block lookups with subtle boundaries.
Almost everything follows a snake_case verb_noun pattern (get_*, list_*, search_*, render_*, validate_*, open_/load_project). Minor deviation: singular listing tools use get_ for plurals (get_tags, get_types, get_pous, get_udts) while others use list_ (list_library_blocks, list_fb_catalog, list_languages), plus singular/plural alias pairs.
At 28 tools this is heavy, though the PLC-analysis domain genuinely spans projects, sources, POUs, tags, types, FBs, tasks, motion, I/O, search, conventions, validation and rendering. The count is inflated by two redundant alias pairs and overlapping type/block tools that could be consolidated.
The read/analysis surface is comprehensive (projects, POUs, tags, types, FBs, library, tasks, motion, I/O, search, conventions) and adds validation plus code/type rendering, so most workflows have no dead ends. The main gap is that rendering is export-shaped only, with no verified import/write path back into the project.
Related MCP Connectors
Code intelligence platform for AI agents. 20 tools for architecture, security & impact analysis.
Turn datasheets into source-backed JSON contracts, pinout matrices, and KiCad CAD for AI agents.
Run, build, and validate firmware on virtual hardware from your AI agent. Hardware knowledge corpus.
OCR, transcription, file extraction, and image generation for AI agents via MCP.
Related MCP Servers
- AlicenseBqualityDmaintenanceEnables AI agents to discover, inspect, edit, rebuild, and save Schneider Electric RemoteConnect and SCADAPack x70 IEC logic projects, including program sections, hardware, variables, and Modbus configuration.631MIT
- FlicenseAqualityCmaintenanceLets AI agents and users analyze Mitsubishi MELSEC .gx3 projects directly, tracing coil conditions, checking device references, comparing program changes, and inspecting ladder logic without opening GX Works3.134-
- FlicenseNot gradedqualityCmaintenanceEnables AI agents to connect to Allen-Bradley, Siemens, and CODESYS PLC projects for discovering, asking questions about, analyzing, and proposing code changes, with access to live tag values and version exports under permission-scoped controls.-
- AlicenseNot gradedqualityBmaintenanceEnables AI assistants to automate CODESYS V3 PLC development, including project editing, builds, library and alarm management, online variable read/write/force operations, and CODESYS documentation search via MCP.4MIT