Skip to main content
Glama
codesys-mcp-server

codesys-mcp-server

by NPavii

CODESYS MCP

CODESYS V3 automation through MCP: project editing, Structured Text refactoring, PLC operations, and searchable engineering documentation.

Node.js 20+ TypeScript CODESYS V3 MIT License

Quick start · Capabilities · Architecture · Security · Configuration · Development

A Model Context Protocol server for CODESYS Development System V3. It combines project and PLC automation through the CODESYS ScriptEngine with searchable, curated engineering documentation.

The server supports local stdio integration and an authenticated Streamable HTTP endpoint. HTTP is read-only for CODESYS operations by default.

Highlights

  • Create and inspect POUs, interfaces, DUTs, GVLs, methods, properties and actions.

  • Edit Structured Text, build applications and manage project libraries.

  • Work with devices, tasks, PLCopenXML, symbol configuration and network variable lists.

  • Read, write, force and monitor online values; manage the application lifecycle where explicitly enabled.

  • Search curated CODESYS guidance, local PDF manuals and allowlisted official documentation.

  • Use snapshots, dry runs and project-wide reference analysis before risky changes.

  • Run a warm CODESYS daemon for low-latency operations or an isolated cold process per call.

Related MCP server: CODESYS MCP Server

Requirements

  • Node.js 20 or newer.

  • npm.

  • Windows and CODESYS Development System V3 with ScriptEngine for project or PLC automation.

  • Documentation tools do not require a CODESYS installation.

Installation

git clone https://github.com/NPavii/codesys-mcp.git
cd codesys-mcp
npm install
npm run build

For agent-guided installation and client registration, see agent.md.

Quick start

npm run start:stdio

Or register the built entry point directly:

node dist/src/cli.js --stdio

Stdio does not require an HTTP token. It exposes the complete trusted-local toolset, including codesys_eval, and inherits the launching user's permissions.

HTTP

Generate a token and place it in .env:

cp .env.example .env
node -e "console.log(require('node:crypto').randomBytes(32).toString('hex'))"
MCP_TOKEN=<generated-token>

Start the server:

npm start

The default endpoint is:

http://127.0.0.1:3000/mcp

Clients must send:

Authorization: Bearer <MCP_TOKEN>

HTTP defaults to loopback only, denies browser Origins and exposes only read-only CODESYS tools. See SECURITY.md before enabling network access or write operations.

Architecture

MCP client
   │
   ├── stdio
   │
   └── authenticated HTTP
           │
           ▼
   Transport and tool policy
           │
           ▼
      Node.js bridge
           │
           ├── cold CODESYS process per operation
           │
           └── warm daemon with a per-user task queue
                       │
                       ▼
             CODESYS ScriptEngine
                       │
             .project / .library / PLC

The warm daemon keeps the ScriptEngine session open and reduces typical operation latency from tens of seconds to a few seconds. Exactly one daemon should serve one isolated bridge runtime.

Multiple agents working on different projects should use separate MCP processes and isolated bridge runtimes. They must not share a daemon, queue, ping file, project file or online PLC session.

Tool catalogue

Area

Representative tools

Project inspection

codesys_project_open, codesys_project_info, codesys_list_objects, codesys_get_object, codesys_dump_pou_code

Project editing

codesys_create_pou, codesys_create_member, codesys_create_interface, codesys_create_dut, codesys_create_gvl, codesys_set_code

Refactoring

codesys_find_references, codesys_rename_object, codesys_rename_symbol, codesys_move_object

Build and lifecycle

codesys_build, codesys_application_build_action, codesys_clean_all, codesys_save_project, codesys_save_project_as

Libraries

codesys_lib_install, codesys_lib_add, codesys_lib_remove, codesys_lib_list, codesys_validate_library

Tasks and devices

codesys_list_tasks, codesys_configure_task, codesys_add_device, codesys_device_info, codesys_set_device_parameter

Data exchange

codesys_export_plcopen_xml, codesys_import_plcopen_xml, codesys_native_export, codesys_native_import, codesys_io_mappings_csv

Online operations

codesys_online_login, codesys_online_read, codesys_online_write, codesys_online_force, codesys_monitor_variables

PLC application

codesys_download_application, codesys_application_start_stop, codesys_application_reset, codesys_boot_application_create

PLC files and source

codesys_plc_file_list, codesys_plc_file_transfer, codesys_plc_file_delete, codesys_source_download, codesys_source_upload

Symbols and NVL

codesys_symbol_config_create, codesys_symbol_config_set_access, codesys_nvl_sender_set, codesys_nvl_receiver_create

Safety and recovery

codesys_snapshot, codesys_snapshot_list, codesys_snapshot_restore, codesys_online_change_check

Documentation

search_codesys_docs, get_codesys_topic, codesys_writing_guidance, list_codesys_pdfs, search_codesys_pdfs, get_codesys_pdf

Official online help

get_codesys_page, crawl_codesys_help

Destructive operations that accept confirm require an explicit confirm: true. This field is an operational safeguard, not a replacement for authentication or authorization.

  1. Inspect the project tree and read existing objects before editing.

  2. Keep the target project closed in the CODESYS GUI while the bridge owns it.

  3. Create a snapshot before risky changes.

  4. Use codesys_batch for related edits; use dry-run mode when available.

  5. Run builds as standalone operations, not inside a batch.

  6. Treat the compiler summary as the build verdict and resolve errors and warnings.

  7. Close the project or stop the warm daemon before returning to manual GUI work.

Warm daemon

Start the configured launcher:

bridge/bridge_daemon.cmd

Useful environment switches:

Variable

Purpose

CB_MONITOR=0

Do not open the companion monitor window.

CB_KEEP=1

Do not terminate existing CODESYS processes before startup.

CB_QUEUE_DIR

Override the per-user warm-daemon queue. Keep its ACL private.

CB_WARM_PROJECTS

Semicolon-separated project list for warm-up.

CODESYS_BRIDGE_AUTOSTART=0

Disable daemon auto-start from MCP.

Machine-specific paths belong in bridge/bridge_daemon.local.ps1, which is excluded from Git and npm packages.

Configuration

Variable

Default

Description

PORT

3000

HTTP port.

HOST

127.0.0.1

Bind host. Non-loopback requires HTTP_ALLOWED_HOSTS.

MCP_TOKEN

empty

Required for HTTP; minimum 32 characters.

HTTP_ALLOWED_HOSTS

local hosts

Comma-separated exact Host allowlist.

HTTP_ALLOWED_ORIGINS

empty

Exact browser Origin allowlist; empty denies browser calls.

HTTP_ENABLE_WRITES

false

Enables CODESYS writes and online control over HTTP.

HTTP_ENABLE_EVAL

false

Independently enables ScriptEngine eval over HTTP.

HTTP_ENABLE_BATCH

false

Enables batch; nested batch and disallowed operations remain blocked.

HTTP_MAX_SESSIONS

16

Maximum simultaneous MCP sessions.

HTTP_SESSION_TTL_SECONDS

1800

Idle session lifetime.

HTTP_RATE_LIMIT_PER_MINUTE

120

Per-source HTTP request limit.

OFFICIAL_LOOKUP_ENABLED

true

Enables allowlisted official CODESYS lookup.

OFFICIAL_LOOKUP_TIMEOUT_MS

3500

Fetch timeout per official page.

OFFICIAL_LOOKUP_CACHE_TTL_SECONDS

3600

In-memory documentation cache TTL.

EXTERNAL_MAX_RESPONSE_BYTES

2000000

Streaming limit for external responses.

PDF_SEARCH_ENABLED

true

Enables local PDF extraction and search.

PDF_DOCS_DIR

docs/pdfs

Folder scanned for .pdf files.

PDF_MAX_TEXT_CHARS

200000

Maximum extracted text stored per PDF.

PDF_MAX_FILE_BYTES

50000000

PDFs above this size are skipped.

CODESYS_EXE

auto-detected

Full path to CODESYS.exe.

CODESYS_PROFILE

CODESYS V3.5 SP21 Patch 1

Profile used for headless execution.

CODESYS_BRIDGE_DIR

bridge/

Bridge runtime directory.

CODESYS_BRIDGE_TIMEOUT_MS

240000

Bridge operation timeout.

CODESYS_BRIDGE_MAX_QUEUE

32

Maximum pending bridge calls.

Enabling writes does not enable batch or eval. Non-loopback HTTP must be placed behind an HTTPS reverse proxy.

Local documentation

Place PDF manuals, datasheets and project notes in:

docs/pdfs/

The server extracts and indexes their text. Scanned PDFs without a text layer may require OCR. Engineering decisions should always be checked against the original document and the target runtime.

Operational notes

  • Text writes require the project to be primary in the ScriptEngine session; the bridge handles promotion and demotion.

  • Create interfaces empty and add members individually. Do not replace an interface declaration with codesys_set_code.

  • Do not place build, clean or close-project operations inside codesys_batch.

  • Incremental builds can hide errors after type changes; perform a clean build when required.

  • Changing types of existing persistent variables can invalidate the persistent list; prefer adding new variables.

  • Some ScriptEngine operations vary by CODESYS service pack. The bridge returns an error instead of silently claiming success.

Security

Read SECURITY.md for the security model, private vulnerability reporting and release requirements.

Key defaults:

  • local-only HTTP binding;

  • mandatory HTTP authentication;

  • no wildcard CORS;

  • exact Host and Origin validation;

  • read-only HTTP CODESYS tools;

  • independent write, batch and eval opt-ins;

  • bounded sessions, requests, queues and external responses;

  • no runtime artifacts in npm packages.

Development and verification

npm test
npm run build
npm run lint
npm audit
npm run pack:check

The test suite includes functional tests and dedicated security suites for HTTP boundaries, tool policy, resource limits, secret-bearing artifact cleanup and package contents.

License

Released under the MIT License. See LICENSE.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers