mcp-server-siglent-sdm3045x

mcp-server-siglent-sdm3045x

by shaag7967

mcp-server-siglent-sdm3045x

An MCP server that lets AI assistants take measurements with a Siglent SDM3045X bench multimeter connected via USB or LAN.

Unofficial project, not affiliated with or endorsed by Siglent. Tested with an SDM3045X, firmware 5.02.01.10, over USB (Linux) and LAN.

Tools

Tool

Description

read

One reading with the function and range set on the instrument, keeping them

measure

Select a function (DC/AC voltage and current, 2/4-wire resistance, capacitance, frequency, period, continuity, diode, temperature) and take one reading

sample

Timestamped readings over a period (max 600 s, interval ≥ 0.1 s) with min/max/mean/stdev

burst

Up to 10000 readings as fast as the instrument can (about 180/s at speed fast), with statistics

get_device_info

Model, serial number, firmware, connection and the present measurement configuration

Every reading comes with its unit, the range used and, where the data sheet gives a single figure, its accuracy (e.g. ±(0.06 % of reading + 8 counts) as an absolute value). Overloads are reported as "overload": true instead of the instrument's 9.9E37.

With --allow-scpi one more tool is available:

Tool

Description

scpi

Send any SCPI command or query from the Remote Manual (statistics, limits, null, …)

The raw SCPI tool is off by default because it can change any setting, including the LAN configuration.

Related MCP server: rigol-oscilloscope-mcp

Requirements

  • Python ≥ 3.10 and uv

  • The instrument connected to the USB device port on the rear, or to the network.

  • Linux, USB: the kernel usbtmc driver makes the instrument available as /dev/usbtmc0. Give logged-in users access with a udev rule:

    echo 'SUBSYSTEM=="usbmisc", KERNEL=="usbtmc[0-9]*", TAG+="uaccess"' | sudo tee /etc/udev/rules.d/70-usbtmc.rules
    sudo udevadm control --reload && sudo udevadm trigger
  • Windows / macOS, USB: install a VISA (NI-VISA or Keysight IO Libraries) and start the server with --visa-backend @ivi.

  • LAN: no extra software. The instrument needs an address in your subnet; then the server finds it by itself. On the instrument open Utility → I/O Config → LAN Settings and turn on DHCP, or enter a static IP address, subnet mask and gateway under Modify Settings (User Manual, section I/O Configuration, available on the Siglent product page). Check that the instrument's subnet matches your network: ours came with the static address 10.11.13.220, which the broadcast search does not reach. While USB is connected, SYST:COMM:LAN:IPAD? (e.g. with the scpi tool) shows the address in use.

Configuration

Claude Code

claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x
# fixed address instead of auto-detection:
claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x --resource 192.168.1.50

Claude Desktop and other clients

{
  "mcpServers": {
    "siglent-sdm3045x": {
      "command": "uvx",
      "args": ["mcp-server-siglent-sdm3045x"]
    }
  }
}

Options

Option

Environment variable

Default

--resource RESOURCE

SDM_RESOURCE

auto-detect on USB, then LAN

--serial SERIAL

SDM_SERIAL

any SDM3045X

--allow-scpi

SDM_ALLOW_SCPI=1

off

--visa-backend BACKEND

SDM_VISA_BACKEND

@py (pyvisa-py)

--log-level LEVEL

SDM_LOG_LEVEL

WARNING (or DEBUG, INFO, ERROR, CRITICAL)

RESOURCE can be a device file (/dev/usbtmc0), an IP address or host name (VXI-11), or any VISA resource string such as TCPIP::192.168.1.50::5025::SOCKET (raw socket) or USB0::0xF4EC::0x1203::SDM34XXXXXXXXX::INSTR. Port 5024 is a telnet console and does not work as a socket resource.

Auto-detection tries /dev/usbtmc* first, then Siglent instruments listed by VISA on USB (leaving out those already asked through /dev/usbtmc*, since pyvisa-py would take them away from the kernel driver), then VXI-11 instruments in every network this computer is connected to (UDP broadcast to the portmapper, about 1 s). It accepts the first one that identifies itself as an SDM3045X. With several instruments, --serial picks one by its serial number (shown by get_device_info, on the rear label and under Utility → System Setup → System Info). Set --resource instead if the instrument is in another subnet, where the broadcast does not reach it; the two options exclude each other.

Measurement notes

  • The server cannot see how the test leads are connected. It tells the assistant to only switch to functions that match the wiring: currents need the red lead in the I jack; resistance, continuity, diode and capacitance drive a test current of up to 1 mA through the circuit.

  • Switching function or range remotely also changes what the front panel shows.

  • Once the server has sent a command, the instrument is in remote mode: the front panel shows "Immediate Trig" and its keys are locked. Press Shift to return to front panel operation. The instrument offers no remote command for this, so the server cannot release it by itself.

  • Above 7 A, the data sheet recommends 30 s off after 30 s on.

  • Accuracy figures are the one-year data sheet values (23 °C ± 5 °C, 30 min warm-up, speed slow). 2-wire resistance adds 0.2 Ω unless the leads were nulled; AC accuracy depends on the signal frequency and is given per frequency band; thermocouple figures exclude the cold junction error (up to ±3.5 °C with the built-in sensor).

Development

uv sync
uv run pytest                                   # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-siglent-sdm3045x   # try the tools interactively

To check a real instrument, connect it and run:

uv run python scripts/hardware_test.py                      # voltage-type functions only
uv run python scripts/hardware_test.py --with-test-current  # also resistance, current, capacitance, …
uv run python scripts/hardware_test.py --reconnect          # also unplug/replug USB when asked

The basic checks only use functions that put no current into the inputs. Observed instrument behaviour, including where it differs from the Remote Manual, is described in docs/protocol.md.

License

MIT

Available Tools

5 tools
burstA
Idempotent

Take a series of readings as fast as the instrument can and return statistics plus all values.

Readings are paced by the instrument and have no individual timestamps. Approximate rates (50 Hz mains): dc_voltage, dc_current and resistance 4/s at speed slow, 40/s medium, 175/s fast; ac functions and temperature 4/s; frequency and period 2/s. Bursts estimated to take longer than 600 s are refused. Without function the present function and range are kept; otherwise they are set as in measure.

Args: count: Number of readings, 1 to 10000. function: Measurement function. Leads in HI/LO for voltage, resistance_2w, capacitance, frequency, period, continuity, diode and temperature; in I/LO for currents; resistance_4w also uses HI Sense/LO Sense. range: Fixed range in V, A, Ω or F; omit for autorange. dc_voltage 0.6, 6, 60, 600, 1000; ac_voltage 0.6, 6, 60, 600, 750; dc_current 0.0006, 0.006, 0.06, 0.6, 6, 10; ac_current 0.06, 0.6, 6, 10; resistance_2w/resistance_4w 600, 6000, 60000, 600000, 6e6, 6e7, 1e8; capacitance 2e-9, 2e-8, 2e-7, 2e-6, 2e-5, 0.0002, 0.01. Other functions have no range. speed: Only for dc_voltage, dc_current, resistance_2w, resistance_4w: slow (10 PLC, default, most accurate), medium (1 PLC), fast (0.3 PLC). sensor: Required for temperature: pt100 (RTD) or thermocouple type B, E, J, K, N, R, S or T.

Inputs: count, range, speed, sensor, +1 more. Returns: object

get_device_infoB
Read-onlyIdempotent

Instrument model, serial number, firmware, VISA resource and the present measurement configuration.

Inputs: no named parameters. Returns: object

measureA
Idempotent

Select a measurement function and take one reading.

This switches the instrument (front panel included) to the given function, with autorange unless a range is given. Returns value, unit, range used, timestamp (UTC) and, where the data sheet allows, the accuracy of the reading.

Args: function: Measurement function. Leads in HI/LO for voltage, resistance_2w, capacitance, frequency, period, continuity, diode and temperature; in I/LO for currents; resistance_4w also uses HI Sense/LO Sense. range: Fixed range in V, A, Ω or F; omit for autorange. dc_voltage 0.6, 6, 60, 600, 1000; ac_voltage 0.6, 6, 60, 600, 750; dc_current 0.0006, 0.006, 0.06, 0.6, 6, 10; ac_current 0.06, 0.6, 6, 10; resistance_2w/resistance_4w 600, 6000, 60000, 600000, 6e6, 6e7, 1e8; capacitance 2e-9, 2e-8, 2e-7, 2e-6, 2e-5, 0.0002, 0.01. Other functions have no range. speed: Only for dc_voltage, dc_current, resistance_2w, resistance_4w: slow (10 PLC, default, most accurate), medium (1 PLC), fast (0.3 PLC). sensor: Required for temperature: pt100 (RTD) or thermocouple type B, E, J, K, N, R, S or T.

Inputs: function (required), range, speed, sensor. Returns: object

readA
Idempotent

Take one reading with the function, range and speed currently set on the instrument.

Function, range and speed are kept; the trigger is set to immediate with one reading per trigger, as measure does. Returns value, unit, range, timestamp (UTC) and, where the data sheet allows, the accuracy.

Inputs: no named parameters. Returns: object

sampleA
Idempotent

Record timestamped readings at a fixed interval and return statistics plus all samples.

Readings are paced by this computer. A reading takes about 0.3 s at speed slow and in most other functions, 0.6 s for frequency and period; with a shorter interval readings are taken back to back, and none starts later than one interval after duration_s, so the recording ends on time with fewer samples. Without function the present function and range are kept; otherwise they are set as in measure.

Args: duration_s: Recording time in seconds (max 600). interval_s: Time between readings in seconds (min 0.1). function: Measurement function. Leads in HI/LO for voltage, resistance_2w, capacitance, frequency, period, continuity, diode and temperature; in I/LO for currents; resistance_4w also uses HI Sense/LO Sense. range: Fixed range in V, A, Ω or F; omit for autorange. dc_voltage 0.6, 6, 60, 600, 1000; ac_voltage 0.6, 6, 60, 600, 750; dc_current 0.0006, 0.006, 0.06, 0.6, 6, 10; ac_current 0.06, 0.6, 6, 10; resistance_2w/resistance_4w 600, 6000, 60000, 600000, 6e6, 6e7, 1e8; capacitance 2e-9, 2e-8, 2e-7, 2e-6, 2e-5, 0.0002, 0.01. Other functions have no range. speed: Only for dc_voltage, dc_current, resistance_2w, resistance_4w: slow (10 PLC, default, most accurate), medium (1 PLC), fast (0.3 PLC). sensor: Required for temperature: pt100 (RTD) or thermocouple type B, E, J, K, N, R, S or T.

Inputs: range, speed, sensor, function, +2 more. Returns: object

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.9/5.0

    Scored across 5 tools

    Disambiguation4/5

    The single-reading tools read and measure overlap somewhat, but the descriptions clearly distinguish them: read preserves current configuration, while measure changes function/range and takes a reading. sample and burst are clearly differentiated by pacing, timestamps, and statistics. get_device_info is distinct.

    Naming Consistency3/5

    Most tool names are single imperative verbs (read, measure, sample, burst), but get_device_info uses a verb_noun convention with a get_ prefix. The mix is readable but not a consistent predictable pattern.

    Tool Count5/5

    Five tools is well-scoped for a bench multimeter server: immediate reading, configured measurement, timed sampling, fast burst capture, and device information. Each tool has a clear purpose and earns its place.

    Completeness4/5

    The surface covers core measurement workflows including single readings, configured readings, sampling, burst acquisition, and device/configuration info. A configure-only tool or explicit trigger/zero controls are missing, but agents can work around this via measure.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues

    Related MCP Connectors

    Related MCP Servers

    • F
      license
      Not graded
      quality
      D
      maintenance
      MCP server to remotely control Siglent SDM3000 series digital multimeters via TCP/IP SCPI protocol, enabling measurement, configuration, and data acquisition.
      -
    • A
      license
      A
      quality
      C
      maintenance
      Enables LLMs to control RIGOL oscilloscopes over SCPI via LAN or USB, including configuring channels/timebase/trigger, taking measurements, capturing waveforms and screenshots, decoding serial protocols, running FFT analysis, and controlling the built-in AFG.
      38
      MIT
    • A
      license
      Not graded
      quality
      C
      maintenance
      Enables MCP clients to connect to and control Siglent oscilloscopes and power supplies over SCPI/TCP using typed tool calls with input validation, safety controls, and built-in observability.
      1
      Apache 2.0
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables Claude or users to control SCPI-compatible oscilloscopes over Ethernet or USB, including measuring signals, changing settings, sending queries/writes, and capturing screenshots.
      MIT