Skip to main content
Glama

PCBviber

An MCP server that lets Claude, Cursor, or any MCP client work inside a live Altium Designer session: read the active project, list components and nets, run DRC, check production readiness, export manufacturing outputs, and look up parts on Octopart.

Status: alpha. The MCP server, the tool surface and the relay protocol are covered by automated tests. Most of the Altium-side commands were written against Altium's documented scripting API and have not yet been exercised on a wide range of real designs. Use it on a copy of your project, and please open an issue with what works and what does not. See Verification status.

Quick start

Requirements: Node.js 20+, Altium Designer 24 on Windows.

The package is installed straight from the latest GitHub release (it is not on the npm registry yet), so the commands below use the release URL.

1. Add the server to your MCP client.

Claude Code:

claude mcp add pcbviber -- npx -y pcbviber

Claude Desktop / Cursor (mcpServers in the client's config file):

{
  "mcpServers": {
    "pcbviber": { "command": "npx", "args": ["-y", "pcbviber"] }
  }
}

2. Load the relay script in Altium.

npx -y pcbviber --relay-script

prints the path of AltiumRelay.js. In Altium Designer: File → Run Script…, choose JavaScript Script, pick that file, put the caret inside function Main() and press F9. Details and troubleshooting: ad-script/README.md.

3. Ask your client to call ad_ping. A reply with Altium's version means the loop is closed. Then try "audit the active project" or the pcb_project_audit prompt.

No account, no database, no cloud: the server runs on your machine and talks to Altium over 127.0.0.1 only.

Optional: part data

Part search, stock, pricing and Altium 365 library tools use the Nexar API. Set these in your MCP client's env block to enable them; everything else works without them.

Variable

Purpose

NEXAR_CLIENT_ID, NEXAR_CLIENT_SECRET

Octopart / Altium 365 data

ALTIUM_WORKSPACE_URL

Your Altium 365 workspace, for list_projects and library tools

PCBVIBER_RELAY_PORT

Loopback port Altium polls (default 3000; change RELAY_URL in AltiumRelay.js to match)

Related MCP server: jlc-mcp

What it can do

57 tools and 3 prompts. Full reference with per-tool platform notes: docs/tools.md.

Stage

Representative tools

Project

get_active_project, ad_list_documents, screenshot, pcbviber_audit_project

Parts

search_parts, check_part_availability, find_alternative_parts, analyze_bom_cost

Layout

get_components, move_component, rotate_component, lock_component, place_by_group

Routing

get_net_routing, get_design_rules, unroute_net, route_diff_pair, via_stitch_plane

Verification

validate_placement, run_drc, production_readiness_check

Manufacturing

export_gerbers, export_drill, export_bom, export_pick_and_place

Prompts turn the tool list into a workflow:

Prompt

Use when

pcb_design_flow

Starting a board; walks the nine stages from project setup to manufacturing docs

pcb_project_audit

Assessing a half-built project; produces a prioritized fix list

pcb_dfm_review

Final production-readiness gate against your fab's capabilities

A tool that cannot do its job on your setup returns supported: false with the reason, rather than guessing.

How it works

MCP client ── stdio ──► pcbviber ◄── HTTP poll (127.0.0.1) ── AltiumRelay.js inside Altium Designer
                           │
                           └── HTTPS ──► Nexar / Octopart (optional)

Altium's script engine cannot open sockets or WebSockets, so the relay script polls a loopback endpoint for commands and posts results back. The listener binds to 127.0.0.1 and has no authentication: anything running on your machine can reach it. Do not forward that port.

Verification status

Area

State

MCP server start-up, tool and prompt registration

Automated smoke test (apps/local/test/smoke.mjs)

Relay protocol: command dispatch, result round-trip, malformed input

Automated smoke test with a simulated Altium

Tool handlers, platform layer

Unit tests under apps/server/src

ping against real Altium Designer 24

Verified during development

Other Altium-side commands

Written from the documented scripting API; per-command status in ad-script/README.md

EasyEDA Pro

Experimental; needs the hosted server, see below

Repository layout

Path

What

apps/local

The pcbviber npm package: single-user, stdio + loopback relay

apps/server

Tool handlers and the multi-tenant HTTP server

ad-script

AltiumRelay.js, the script that runs inside Altium Designer

eda-script

EasyEDA Pro extension (experimental)

apps/web, packages/*

Browser UI, auth, billing and metering for the hosted server

The hosted, multi-user server (Postgres, SSO, browser UI, EasyEDA bridge) is documented in docs/hosted-server.md. You do not need it to use PCBviber locally.

Development

pnpm install
pnpm -F pcbviber test     # bundles apps/local and runs the end-to-end smoke test

Contributing

Reports from real boards are the most useful contribution right now: which tool, which Altium version, what happened. Fixes to individual relay commands in ad-script/AltiumRelay.js are welcome as small pull requests. See CONTRIBUTING.md.

License

MIT. PCBviber is an independent project and is not affiliated with or endorsed by Altium.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      Not graded
      quality
      D
      maintenance
      Local Model Context Protocol server that exposes EasyEDA Pro design capabilities as MCP tools, enabling project inspection, schematic editing, PCB design, validation, and manufacturing exports through natural language.
      MIT
    • A
      license
      B
      quality
      A
      maintenance
      MCP server for LCSC China (szlcsc.com) enabling component search, parametric filtering, price/stock lookup, datasheet downloads, and EDA asset conversion to Altium formats with local library management.
      6
      25
      MIT
    • A
      license
      B
      quality
      C
      maintenance
      Read-only MCP server that lets AI assistants (Claude Code, Claude Desktop, VS Code, ...) inspect Altium Designer projects — schematics, netlist, BOM and PCB — on Linux, macOS or Windows, without Altium Designer installed.
      13
      4
      AGPL 3.0