Skip to main content
Glama
Proxus Industrial MCP Server

Proxus Industrial MCP Server

Official
by proxus-io

Proxus Industrial MCP Server

Gives AI assistants such as Claude Desktop, Cursor and VS Code read-only access to industrial devices. Supports Modbus TCP and OPC UA (Basic256Sha256, Aes128_Sha256_RsaOaep or Aes256_Sha256_RsaPss with Sign or SignAndEncrypt, or unsecured; anonymous or user-name login).

An AI assistant reads a PLC, decodes a meter value and diagnoses a device that does not answer

Condensed from a real session against simulated devices (docs/demo.json). More at proxus.io/tools/industrial-mcp-server.

Tools

Tool

What it does

list_devices

Configured devices, endpoint, ISA-95 path, connection state

read_address

Raw registers or bits: hr:0, ir:10, coil:5, di:0 or 40001

watch_address

Polls a Modbus address for 1–60 s and summarises how it moved, decoded as uint16, int16, uint32, int32 or float32 in any byte order

decode_registers

Up to 16 registers read every common way: int16/32, uint, float32 in ABCD/CDAB/BADC/DCBA, float64 in both word orders

browse

Children of an OPC UA node (default: Objects folder)

read_nodes

Up to 50 OPC UA variables with data type, quality, status code and source timestamp

watch_nodes

Watches up to 20 OPC UA variables for 1–60 s through a subscription: every change, plus first, last, min, max and average

diagnose_connection

Why a device can't be reached: name, TCP, protocol handshake, security and certificates, login, a test read, identity and clock, step by step with the next thing to try

find_device_map

Searches the register map library by vendor, model or alias, e.g. PM5560

get_device_map

A map's registers (key, address, type, byte order, unit, scale), filtered by a search word

read_named

Reads registers by key from the device's map and returns engineering values with units

verify_device_map

Checks the device's map against the real device and prepares a hardware verification report (read-only)

Nothing can write to a device.

Related MCP server: OPC UA MCP Server

Register maps

With a register map the assistant reads voltage_l1_n instead of guessing that hr:0-1 is a word-swapped float. A map lists every register of a device model: address, data type, byte order, scale (fixed, or a SunSpec scale-factor register), unit and the meaning of enumerated values, with the vendor document it comes from. The binaries include the open Modbus Register Maps collection (energy meters, power analysers, drives, inverters); each release also attaches it as register-maps.json.gz.

Give a Modbus device its map in the configuration, by id or as the path of a map's JSON file:

"meter-1": { "protocol": "modbus-tcp", "host": "192.168.10.40", "map": "schneider-electric/pm5500-pm5600-pm5700" }

maps_dir adds maps (or replaces built-in ones with the same id) from a folder of JSON files, as python3 tools/maps.py build in the collection writes them. A map that does not exist stops the server at start-up with the reason. Maps tell the assistant how to read a register, never to write one: read_named only reads.

Verify a map on your device

Most maps are transcribed from vendor documents. Ask your assistant to verify the device's map: verify_device_map reads every register once (read-only), checks that the values are plausible (floats, frequency, voltage, power factor, energy counters, model) and asks you to compare two values with the device's display. The result is a report and a link that opens a prefilled issue in the map collection; you submit it under your own GitHub account, and a bot adds you to the map's verified list. Nothing is sent without you, and the report holds check results only, no addresses, host names or serial numbers.

OPC UA security

Set security_mode (sign_and_encrypt, sign or none) and security_policy (Basic256Sha256, Aes128_Sha256_RsaOaep or Aes256_Sha256_RsaPss) per device. Certificates live in pki_dir (default pki/ next to the configuration file), in the layout most OPC UA tools use:

Folder

Holds

own/

This server's application certificate, created on first use (private key readable only by you)

trusted/

Server certificates you approved

rejected/

Server certificates seen but not approved

Trust is never automatic, in either direction:

  1. On the first connection the server's certificate lands in rejected/ and the tool answers with its SHA-256 thumbprint. Confirm the thumbprint with the server's administrator, then move the file to trusted/.

  2. If the server answers BadCertificateUntrusted or BadSecurityChecksFailed, it has not trusted this client yet. proxus-mcp certificate --config <file> prints this server's certificate file and thumbprint to trust on the server.

Passwords never go in the configuration file: password_env names the environment variable that holds them. Errors carry the OPC UA StatusCode name, the specification's description and a suggested next step.

Install

Download the archive for your platform from the releases page, unpack it, and point your MCP client at the proxus-mcp binary (see Claude Desktop below). Each archive has a .sha256 file next to it. The binaries are not code-signed yet: on macOS run xattr -d com.apple.quarantine proxus-mcp once after unpacking, and on Windows choose "More info, Run anyway" the first time.

proxus-mcp --version prints the version.

Docker

docker run -i --rm -v "$PWD:/config" ghcr.io/proxus-io/proxus-mcp:<version>

The image reads /config/proxus-mcp.json and speaks MCP over stdin/stdout, so an MCP client starts it with docker as the command and run -i --rm -v <folder>:/config ghcr.io/proxus-io/proxus-mcp:<version> as the arguments. Devices on the host are reachable as host.docker.internal; on Linux add --network host to reach the plant network directly. Images are published for linux/amd64 and linux/arm64.

Build

Needs the .NET 10 SDK. The protocol drivers come from the Proxus.Drivers NuGet packages (Apache-2.0).

dotnet publish src/Proxus.Mcp.Server -c Release -r osx-arm64 -o artifacts/osx-arm64

The result is one native file, artifacts/osx-arm64/proxus-mcp (about 10 MB).

Claude Desktop

Add to claude_desktop_config.json:

{
  "mcpServers": {
    "proxus": {
      "command": "/absolute/path/to/proxus-mcp",
      "args": ["--config", "/absolute/path/to/proxus-mcp.json"]
    }
  }
}

Copy proxus-mcp.example.json as a starting configuration.

Tests

  • dotnet test tests/Proxus.Mcp.Tests: unit tests, no devices needed.

  • tests/smoke/run_all.sh: the published binary against Modbus and OPC UA simulators (see tests/smoke/README.md).

  • CI (.github/workflows/ci.yml) runs both and publishes Native AOT binaries for linux-x64, linux-arm64, win-x64 and osx-arm64.

Licence

Apache-2.0, see LICENSE.

Related MCP Connectors

Related MCP Servers

  • A
    license
    Not graded
    quality
    F
    maintenance
    Enables AI assistants to interact with Mender IoT platform for device management, deployment monitoring, and fleet analysis through natural language commands. Provides read-only access to device status, deployment logs, releases, and system monitoring capabilities.
    2
    MIT
  • A
    license
    Not graded
    quality
    D
    maintenance
    Connects AI agents to OPC UA-enabled industrial systems for real-time monitoring and control of operational data. It enables users to read, write, and browse industrial device nodes through natural language interactions.
    MIT
  • A
    license
    A
    quality
    D
    maintenance
    Read-only Modbus TCP monitoring server that exposes safe MCP tools for AI agents to read holding/input registers, coils, and device identity from industrial devices without write access.
    4
    Apache 2.0
  • A
    license
    B
    quality
    A
    maintenance
    Provides AI agents with safe, governed read access to industrial control systems (OPC-UA, Modbus, S7, Mitsubishi, MTConnect, MQTT/Sparkplug) plus cross-protocol diagnostics for troubleshooting data breaks, alarm floods, and unhealthy tags.
    156
    9
    MIT