Preliminary sizing math for industrial finishing lines, packaged for AI agents.

This is a Python library, a CLI and an MCP server. It covers the physics and code-cited relationships behind paint and powder booths, cure ovens, air make-up units (AMUs) and overhead conveyors. An agent such as Claude can size a line by calling tested engineering functions instead of guessing numbers.

⚠️ Preliminary sizing aid only. It is not a substitute for equipment-vendor engineering, a licensed engineer's design, or review by the authority having jurisdiction (AHJ) against the code editions in force (NFPA 33, NFPA 86, OSHA 29 CFR 1910.94 / 1910.107, local fire and gas codes).

Why this exists

Sizing a finishing line means juggling four things that depend on each other:

  • Throughput. Production rate and part pitch set the line speed.

  • Air. Booth airflow sets the make-up air, and the make-up air sets a large share of the winter gas bill.

  • Heat. Line speed and the cure schedule set the oven length, and the oven length sets its heat load.

  • Building. Openings, truss heights and stack heights decide whether the line fits at all.

A language model asked to size a line will produce confident numbers with no basis. This toolkit writes the relationships down as small, typed, unit-labelled functions, and every number in a result carries its basis:

basis

meaning

code

value tabulated in a published code or standard (verify the edition your AHJ enforces)

physics

a physical relationship or physical property

public_data

published reference data (e.g. heating value of natural gas)

user_input

supplied by the caller

advisor

supplied by an installed SizingAdvisor plug-in (see below)

Related MCP server: Corrosion Engineering MCP Server

Design principle: public math, user-supplied design basis

The package contains only textbook physics and code-cited relationships. It ships no design defaults. Velocities for cases no public table covers, margins, efficiencies, allowances, part spacing and booth/oven geometry are all required inputs, gathered in a DesignBasis.

In real projects those values come from the equipment vendor, the coating's technical data sheet, the site and the engineer's own experience. A tool that hides them behind defaults gives answers that look more certain than they are. When a value is missing, the agent asks for it.

The design basis can come from two places:

  1. You. Fill in a DesignBasis. examples/design_basis.example.json shows the shape, with illustrative inputs that are not recommendations.

  2. A SizingAdvisor plug-in. This is a separately installed package that holds proprietary or empirical sizing rules and turns a SizingRequest into a DesignBasis. No advisor is included. Without one, suggest_design_basis and plt size --advisor fail with "not included". See Plugging in sizing rules.

What's inside

module

contents

booth

Exhaust airflow Q = A × V for crossdraft, open-face, downdraft and enclosed booths; controlling area per booth type; OSHA Table G-10 velocities for liquid spray booths

amu

Make-up air; burner input from Q = 1.08 × cfm × ΔT; altitude correction; gas flow

oven

Dwell = path length ÷ speed; check against heat-up + cure schedule; required path length; steady-state heat balance (product + hangers + chain + exhaust + walls); NFPA 86 solvent-ventilation screen

conveyor

Throughput, required line speed, carrier pitch, carrier/hook load check, index-conveyor cycle

clearance

Part vs silhouette opening; equipment vs bottom of truss; stack discharge vs roof

advisor

SizingRequest, DesignBasis, the SizingAdvisor protocol and the not-included stub

line

size_line() chains all of the above into one report with every assumption and warning

mcp_server

Everything above as MCP tools, with JSON-schema inputs and structured outputs

cli

plt size ..., plt basis-schema

Units are US customary, as on most North American equipment data sheets. Every field name carries its unit (_ft, _fpm, _cfm, _btuh, _f, _lb), and results also report SI (m³/h, kW, °C, m/min).

Install

pip install -e ".[dev]"      # library, CLI, MCP server, test tools
pip install -e ".[agent]"    # + Anthropic SDK for examples/agent_demo.py

Python 3.11+.

Worked example

A liquid line: 120 parts/hour; parts 4 × 4 × 1 ft (length along the line × height × width), 60 lb, steel. Bake 20 min at 325 °F metal temperature. Near Toronto.

plt size --rate 120 --part 4x4x1 --weight 60 --coating liquid \
         --cure 20 --cure-temp 325 --basis examples/design_basis.example.json

The example design basis uses these illustrative inputs, not recommendations:

  • 2 ft gap between parts; all carriers loaded.

  • 8 lb hanger; 200 lb carrier rating; 2.5 lb/ft chain.

  • Crossdraft booth with a 14 × 8 ft face (112 ft²) at 100 fpm. The velocity is from OSHA Table G-10: large booth, air-operated guns, crossdraft up to 50 fpm.

  • 12 min heat-up; 350 °F oven air; 3,000 ft² oven envelope at U = 0.12.

  • Oven exhaust from the NFPA 86 screen at 2 gal/h of solvent.

  • No design margin; burner efficiencies 0.85 (oven) and 0.9 (AMU).

  • −4 °F winter design; 65 °F supply air; 570 ft elevation.

step

calculation

result

carrier pitch

4 ft part + 2 ft gap

6 ft

line speed

120 parts/h × 6 ft ÷ 60

12 fpm (3.66 m/min)

carrier load

60 + 8 lb vs 200 lb rating

68 lb (34 %)

booth

112 ft² × 100 fpm

11,200 cfm (19,029 m³/h)

oven path

12 fpm × (12 + 20) min

384 ft heated path, 32 min dwell

oven exhaust

10,000 scf/gal × 2 gal/h ÷ 60

333 scfm (NFPA 86 screen)

oven heat balance

product 220,320 + hangers 29,376 + chain 55,080 + exhaust 100,800 + walls 100,800

506,376 BTU/h (148 kW)

oven burner

÷ 0.85

595,736 BTU/h

AMU

1.08 × 11,533 cfm × 69 °F × 0.983 (altitude)

845,220 BTU/h to the air; 939,134 BTU/h gas input (275 kW)

stack

proposed top at 34 ft vs roof 26 ft + 10 ft

flagged: 2 ft short

The report lists 31 assumptions, each with its basis, and the warnings. The stack check catches that the proposed stack top is 2 ft lower than the input requires.

Use it from an AI agent (MCP)

The MCP server exposes these tools:

  • Whole line: size_line, suggest_design_basis.

  • Booth: osha_g10_velocity, booth_exhaust_airflow.

  • AMU and oven: amu_sizing, oven_dwell_check, oven_heat_load, nfpa86_solvent_ventilation.

  • Conveyor: conveyor_throughput, conveyor_required_speed, hook_load_check, index_cycle.

  • Clearances: part_clearance_check, building_clearance_check.

  • Sources: list_references.

The server's instructions tell the agent never to invent design values.

Claude Desktop. Add this to claude_desktop_config.json, using the Python that has the package installed:

{
  "mcpServers": {
    "paint-line-toolkit": {
      "command": "C:/path/to/venv/Scripts/python.exe",
      "args": ["-m", "paint_line_toolkit.mcp_server"]
    }
  }
}

Claude Code:

claude mcp add paint-line-toolkit -- python -m paint_line_toolkit.mcp_server

or commit a project .mcp.json:

{ "mcpServers": { "paint-line-toolkit": { "command": "plt-mcp" } } }

Docker (stdio): docker build -t paint-line-toolkit ., then {"command": "docker", "args": ["run", "-i", "--rm", "paint-line-toolkit"]}.

Example agent session

This is an illustrative transcript. The tool calls and responses are what the server returns, and the assistant's text is condensed.

User: I need to powder-coat 120 parts/hour, parts 4×4×1 ft, max 60 lb each; size the booth, oven, AMU and conveyor. Cure is 10 min at 400 °F. We're near Toronto.

-> suggest_design_basis({"request": {"rate_parts_per_hour": 120, "part_length_ft": 4, ...,
                                     "coating": "powder", "cure_metal_temp_f": 400, "cure_time_min": 10}})
<- error: Sizing advisor not included. This public package ships no proprietary or empirical
   sizing rules. Supply a DesignBasis yourself ...
-> conveyor_required_speed({"target_parts_per_hour": 120, "spacing_ft": 6})
<- required_speed_fpm 12.0  (assuming a 2 ft gap, to be confirmed)
-> oven_dwell_check({"path_length_ft": 240, "line_speed_fpm": 12, "cure_time_at_temp_min": 10,
                     "heat_up_min": 10})
<- dwell_min 20.0, meets_schedule true

Assistant: I can do the kinematics now. With a 2 ft gap (please confirm), the line runs at 12 fpm. A 240 ft heated path gives 20 min dwell, which covers 10 min heat-up plus 10 min at 400 °F, if your parts really heat up in 10 min.

To size the booth, oven heat and AMU I need values the toolkit deliberately does not assume:

  1. Booth. Booth type and open area, plus the powder-booth design velocity from your booth vendor. OSHA Table G-10 only covers liquid spray.

  2. Booth air. Whether the booth exhausts outdoors or returns filtered air to the plant.

  3. Oven. Oven exhaust (the vendor's NFPA 86 value), envelope area and panel U-value, your design margin, and the burner efficiency.

  4. Site. Winter design temperature (ASHRAE data for your site), AMU supply temperature and burner efficiency.

  5. Conveyor. Carrier rating, hanger weight and chain weight.

Preliminary sizing aid, not a substitute for vendor engineering or code review.

examples/agent_demo.py runs this loop for real. It starts the MCP server over stdio and gives its tools to Claude through the Anthropic API. It reads only ANTHROPIC_API_KEY from the environment, never a .env file, and skips cleanly if the key is not set.

Plugging in sizing rules

Empirical or proprietary rules plug in through the SizingAdvisor protocol. These are rules that turn a part and a rate into booth geometry, velocities, margins and allowances.

class SizingAdvisor(Protocol):
    name: str

    def suggest(self, request: SizingRequest) -> DesignBasis: ...

Implement it in your own package (examples/advisor_template.py is a skeleton with no rules) and register it:

[project.entry-points."paint_line_toolkit.advisors"]
my-rules = "my_private_rules.advisor:MyAdvisor"

Once it is installed, plt size ... --advisor, the suggest_design_basis MCP tool and size_line_with_advisor() use it. Reports mark that design basis as advisor, so a reader always knows which numbers came from public math and which from your rules. Without a plug-in, the stub raises AdvisorNotIncludedError.

Library use

from paint_line_toolkit import DesignBasis, LineSpec, SizingRequest, size_line, amu_sizing

request = SizingRequest(
    rate_parts_per_hour=120,
    part_length_ft=4,
    part_height_ft=4,
    part_width_ft=1,
    part_weight_lb=60,
    coating="liquid",
    cure_metal_temp_f=325,
    cure_time_min=20,
)
basis = DesignBasis.model_validate_json(open("examples/design_basis.example.json").read())
report = size_line(LineSpec(request=request, basis=basis))

amu = amu_sizing(exhaust_cfm=10_000, design_outdoor_temp_f=0, supply_temp_f=70, burner_efficiency=0.9)
# 1.08 × 10,000 × 70 = 756,000 BTU/h to the air

What is in the math, and what is not

Implemented (public sources):

  • Q = A × V, and the controlling area per booth type (ACGIH, OSHA definitions).

  • OSHA 1910.94(c)(6) Table G-10 minimum velocities for liquid spray booths.

  • NFPA 33 performance criteria: 25 % of LFL for vapours, 50 % of MEC for powder.

  • Sensible heat Q = 1.08 × cfm × ΔT and the standard-atmosphere density ratio (ASHRAE).

  • m·cp·ΔT product heating and U·A·ΔT wall losses (physics), with metal specific heats from property tables.

  • NFPA 86 solvent-ventilation screen: 10,000 scf per gallon.

  • Natural gas ≈ 1,000 BTU/scf, overridable (EIA averages about 1,030–1,040).

  • Conveyor and index kinematics, carrier statics, and clearance geometry.

Not implemented, by design:

  • Transient part heat-up. It is an input; measure it with an oven data logger.

  • Powder-booth velocity tables (no public table) and the NFPA 33 MEC calculation (vendor).

  • Door and opening losses (cover them with your design margin), and chain-pull analysis.

References

These are listed in references.py, and assumptions cite them by id. Always check the edition your AHJ enforces.

  • OSHA 29 CFR 1910.94(c)(6), Table G-10: minimum maintained velocities into spray booths

  • OSHA 29 CFR 1910.107: spray finishing using flammable and combustible materials

  • NFPA 33: Spray Application Using Flammable or Combustible Materials

  • NFPA 86: Ovens and Furnaces

  • ASHRAE Handbook: Fundamentals

  • ACGIH: Industrial Ventilation, A Manual of Recommended Practice for Design

  • U.S. EIA: heat content of natural gas

Development

pip install -e ".[dev]"
pytest            # worked examples, property tests (hypothesis), CLI, advisor interface, MCP round-trip
ruff check . && ruff format --check .
mypy              # strict

License

MIT © Maximiliano Gomez Montero

Available Tools

15 tools
amu_sizingC

Air make-up unit: make-up cfm and burner input, BTU/h = 1.08 × cfm × ΔT (standard air).

Inputs: exhaust_cfm (required), supply_temp_f (required), burner_efficiency (required), design_outdoor_temp_f (required), +4 more. Returns: warnings, delta_t_c, delta_t_f, makeup_cfm, +14 more

booth_exhaust_airflowC

Booth exhaust airflow Q [cfm] = area [ft²] × velocity [fpm].

Inputs: coating (required), booth_type (required), velocity_fpm (required), control_area_ft2 (required), +1 more. Returns: coating, warnings, booth_type, assumptions, +8 more

building_clearance_checkC

Equipment top vs bottom of truss, and exhaust stack discharge height vs roof.

Inputs: roof_height_ft (required), equipment_top_ft (required), bottom_of_truss_ft (required), min_stack_above_roof_ft (required)… Returns: stack_ok, warnings, assumptions, roof_height_ft, +9 more

conveyor_required_speedC

Line speed (fpm) required for a target production rate.

Inputs: spacing_ft (required), target_parts_per_hour (required), parts_per_carrier, loading_efficiency. Returns: warnings, spacing_ft, assumptions, carriers_per_hour, +5 more

conveyor_throughputB

Parts/hour = speed × 60 ÷ pitch × parts per carrier × loading efficiency.

Inputs: spacing_ft (required), line_speed_fpm (required), parts_per_carrier, loading_efficiency. Returns: warnings, spacing_m, spacing_ft, assumptions, +6 more

hook_load_checkC

Carrier check: (part + hanger) × parts per carrier × design factor vs rated load.

Inputs: part_weight_lb (required), hanger_weight_lb (required), rated_capacity_lb (required), spacing_ft, +2 more. Returns: passes, warnings, assumptions, utilization, +5 more

index_cycleC

Indexing conveyor: cycle time, move time and dwell available per station.

Inputs: accel_decel_s (required), index_speed_fpm (required), index_distance_ft (required), target_parts_per_hour (required), +1… Returns: feasible, warnings, assumptions, move_time_s, +5 more

list_referencesC

Codes, standards and references cited by the toolkit.

Inputs: no named parameters. Returns: result

nfpa86_solvent_ventilationA

NFPA 86 screening value for oven safety ventilation: 10,000 scf per gallon of solvent, in scfm.

Inputs: solvent_gal_per_h (required). Returns: result

osha_g10_velocityB

Minimum maintained air velocity into a liquid spray booth, from OSHA 29 CFR 1910.94(c)(6) Table G-10. There is no public table for powder booths: ask the user for the vendor's value.

Inputs: condition (required), booth_size (required). Returns: note, source, max_fpm, min_fpm, +3 more

oven_dwell_checkC

Cure-oven dwell = path length ÷ line speed, checked against heat-up + time at temperature.

Inputs: heat_up_min (required), line_speed_fpm (required), path_length_ft (required), cure_time_at_temp_min (required). Returns: warnings, dwell_min, margin_min, assumptions, +9 more

oven_heat_loadC

Steady-state cure-oven heat balance: product + hangers + chain + exhaust + wall losses.

Inputs: exhaust_scfm (required), design_margin (required), ambient_temp_f (required), part_weight_lb (required), +11 more. Returns: total_kw, warnings, chain_btuh, total_btuh, +12 more

part_clearance_checkC

Hung part cross-section vs a booth/oven silhouette or working opening.

Inputs: part_width_ft (required), part_height_ft (required), min_clearance_in (required), opening_width_ft (required), +1 more. Returns: passes, warnings, assumptions, part_width_ft, +8 more

size_lineA

Preliminary sizing of a whole finishing line (conveyor, booth, oven, AMU, clearances). Needs the sizing request AND a complete design basis; ask the user for any value you lack.

Inputs: spec (required). Returns: amu, spec, booth, summary, +9 more

suggest_design_basisA

Ask an installed SizingAdvisor plug-in for a design basis. The public package ships none, so this normally fails with 'not included': then ask the user for the design values.

Inputs: request (required). Returns: Every design value the calculations need beyond physics and published codes. Al…

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    B3.1/5.0

    Scored across 15 tools

    Disambiguation4/5

    Most tools target clearly separate calculations: AMU sizing, booth airflow, oven heat load, conveyor throughput/speed, hook load, clearances, and code checks. The main ambiguity is between size_line and the individual sizing tools, though size_line is described as whole-line preliminary sizing. part_clearance_check and building_clearance_check could be momentarily confused but operate on different objects.

    Naming Consistency4/5

    All names use snake_case consistently. Most are noun-based calculation labels (amu_sizing, conveyor_throughput, oven_heat_load), while a few are verb-led commands (size_line, suggest_design_basis, list_references); this is a minor deviation but still predictable.

    Tool Count5/5

    Fifteen tools is well within a reasonable range for a specialized engineering toolkit. Each tool covers a distinct calculation or support function, and none appears redundant or filler.

    Completeness4/5

    The surface covers the core paint-line sizing workflow: conveyor, booth exhaust, OSHA/NFPA checks, oven dwell and heat load, AMU, hook/part/building clearances, whole-line sizing, and references. Minor domain gaps remain, such as duct/fan sizing, cooling or flash-off zones, and emissions beyond NFPA screening, but agents can work around them.

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      A
      quality
      D
      maintenance
      Enables AI agents to perform unit-aware engineering calculations with automatic unit conversion, dependency resolution, and access to 500+ units across 75+ categories through the CalcsLive calculation engine.
      3
      21 npm
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Provides AI agents with physics-based corrosion engineering calculations, from rapid handbook lookups to mechanistic electrochemical models with dual-tier pitting assessment for material compatibility screening and corrosion rate prediction.
      1
      MIT
    • F
      license
      Not graded
      quality
      C
      maintenance
      Provides deterministic, standards-based calculations for data center critical power infrastructure. Enables site selection, generator sizing, UPS sizing, NFPA 110 compliance, and more via 50+ AI agents and 8 compound chains.
      -
    • F
      license
      Not graded
      quality
      A
      maintenance
      Enables AI agents to create, edit, validate, and read back production-grade CAD drawings — including P&ID sheets, mechanical parts and assemblies, and architectural floor plans with measured areas and schedules — through a single typed tool contract that runs either live via COM on Windows or headlessly via ezdxf anywhere. It also supports standards-aware dimensioning, ISO GD&T and tolerance checks, takeoff workbooks, and drawing understanding, diffing, and critique.
      -