MeterMind lets an AI agent use a bench multimeter more easily, and now wireless! It's made for the OWON XDM1041 (and tested on a rebadged one, the Digcreat XDM1041-DG). Plug the little MeterMind board into the back of the meter, put it on your WiFi, and your agent can set up the meter and take readings on its own.
Why I made it. The meter's serial connection is full of gotchas: set commands never answer, commands sent while it's busy just vanish, and readings stay stale for a moment after you change modes (PROTOCOL.md). I had a protocol file that smoothed all of that out, and I had to add it to every project that used the meter. Now that work lives on the board, so every project gets the same clean, easy-to-use interface. No cable, no copied code.
No board? You can still skip the gotchas: PROTOCOL.md documents every one, and the
Python version in bridge/ runs on your computer with the meter plugged in over USB, serving the
same API (below).
The board serves:
An MCP server at
/mcp, so AI agents can configure the meter and take measurements.An HTTP/JSON API and a WebSocket stream (API.md). No client library needed.
A dashboard at
http://metermind.local/that works like the meter's front panel: the same screen, keys, ranges and speeds, live readings, and the jacks the leads should be in.Raw SCPI on TCP port 5025 for lab software such as PyVISA.
Install the firmware
From the browser: open the web installer in Chrome or
Edge, connect the board's USB-C port to the computer, press Install and pick the board's
serial port. The installer is built from flasher/ by the release workflow.
From source (ESP-IDF 5.5.2 or later in the 5.5 series; releases are built with 5.5.4):
. ~/esp/esp-idf-v5.5/export.sh
cd firmware
idf.py build
idf.py -p /dev/cu.usbserial-XXXX flash monitor # the board's USB-C porttools/build_flasher.sh makes the same release build the installer ships (from
sdkconfig.defaults only) and assembles flasher/ for local testing.
Related MCP server: ScopeProbe
Connect it to WiFi
On first start the status LED blinks blue and the board opens its own network,
MeterMind-XXXX. Join it from a phone or laptop; the setup page opens by itself (or browse to
http://192.168.4.1/). Pick your 2.4 GHz network and enter its password. Then rejoin your own
network and open http://metermind.local/. Hold BOOT for 3 s to change the network later.
Details, the serial console and the LED colours: firmware/README.md.
Use it
curl metermind.local/api/reading
curl -X POST metermind.local/api/measure -d '{"function":"dcv","samples":5}'
curl -X PUT metermind.local/api/config -d '{"function":"res","range":5000}'Add it to Claude Code as an MCP server:
claude mcp add --transport http metermind http://metermind.local/mcpPyVISA: rm.open_resource("TCPIP::metermind.local::5025::SOCKET", read_termination="\n").
The test leads
The meter cannot sense where the leads are plugged in, so you tell the bridge: tap the jack the
red lead is in on the dashboard, or PUT /api/leads. The bridge then refuses a function or range
that does not suit that jack, for example volts with the red lead in a current jack (which blows
the fuse when the leads touch a voltage source). The dashboard can override after asking you; AI
agents cannot, and are told to ask you instead. The setting starts as "not set" after a restart,
and until it is set, current functions are refused. Rules: API.md.
How it works
One task owns the meter. The ESP32-S3 is a USB host to the meter's CH340 serial chip. A single task holds the link; every client's request goes through its queue, so requests never collide. It polls readings 10 times a second, paces and verifies every set command, and holds readings back after a function or range change until the meter has settled (also while it is still autoranging).
One operation layer for every transport. REST, WebSocket, MCP and raw SCPI call the same operations (
bridge.c), so they validate and behave the same way.The board switches the meter's USB power through a current-limited switch: the firmware can power-cycle a stuck meter link and reports an overload. It also runs the WiFi setup network, mDNS (
metermind.local,_metermind._tcp) and the status LED.A Python prototype in
bridge/serves the same API on a computer with the meter connected over USB. The firmware is a module-for-module port of it, and the two are kept in step.
Path | What it is |
| The ESP32-S3 firmware (ESP-IDF); see firmware/README.md |
| The Python prototype; |
| The web installer page (ESP Web Tools) |
| Order files for the board and how to order it |
| The network API: REST, WebSocket, MCP, SCPI |
| What was learned about the meter's USB and SCPI behaviour |
| End-to-end test against a real meter |
| Release build and installer assembly |
The board
The firmware runs on the MeterMind board: an ESP32-S3-MINI-1-N8, a USB-A socket that connects to the meter through a rigid USB-A-male to USB-B-male adapter, meter USB power through a 0.5 A current-limited switch, USB-C for 5 V power (1 A or more) and a CH340C serial console with auto-reset, an RGB status LED, and BOOT and RESET buttons.
It's open hardware: board/ has the gerbers, BOM, placement file and schematic, and a
step-by-step guide to ordering it assembled from JLCPCB. The pin map is in
firmware/main/board.h; other ESP32-S3 boards with a USB host port should run the firmware after
adjusting it (untested).
Run it without the board
The Python prototype runs on a computer with the meter plugged in over USB:
python3 -m venv .venv && .venv/bin/pip install -r requirements.txt
.venv/bin/python -m bridge # finds the meter's CH340; --mdns advertises metermind.localIt serves the same dashboard and API at http://localhost:8041 (MCP: http://localhost:8041/mcp).
Tests
tools/smoke_test.py [http://metermind.local]: end-to-end against a real meter, through the board or the prototype. Disconnect the probes first. It switches functions (including DC current on the open input), checks the lead rules, MCP and the raw SCPI port, and restores the lead setting afterwards.firmware/tests/run_tests.sh: host tests for the firmware's parser, checked against the prototype's.
Security
There is no authentication: anyone on your network can drive the meter, change the lead setting
and override it. Requests from web pages on other sites are refused (Origin check), which
blocks DNS-rebinding attacks. The WiFi setup network is open unless you set
CONFIG_BRIDGE_SETUP_PASSWORD; it only accepts WiFi changes while setup mode is on (BOOT held for
3 s, or no network saved). Run MeterMind on a network you trust.
Status
Protocol mapped: queries, set commands, ranges, timing quirks
Python prototype: REST, WebSocket, MCP, raw SCPI, mDNS, dashboard
Firmware on the v0.1 board: all transports, WiFi setup with a captive portal, front-panel dashboard, lead setting; smoke test passes on the board
Web installer
Firmware updates over WiFi (two OTA slots are reserved; the update code is not written yet)
Front-panel features the bridge cannot drive yet: Run/Stop, Math, Record, Dual, Rel, and the secondary display
Licence
Copyright (C) 2026 plasmata
The board design in board/ is open hardware under the CERN-OHL-S v2 (board/LICENSE).
Everything else is software:
MeterMind is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. It is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; see LICENSE for details.
Built with, under their own licences: ESP-IDF and Espressif's led_strip, mdns,
usb_host_cdc_acm and usb_host_ch34x_vcp components (Apache-2.0), cJSON (MIT), ESP Web Tools,
which the installer page loads (Apache-2.0), and for the prototype pyserial (BSD), aiohttp
(Apache-2.0) and zeroconf (LGPL). The logo and credit lettering are drawn with the Orbitron font
(SIL Open Font License 1.1).
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
This server cannot be deployed
Maintenance
Related MCP Connectors
Protocol-native energy infrastructure orchestration for AI data centers. Provides 46 MCP tools across 8 grid protocols (IEC-61850, DNP3, Modbus, OCPP, OpenADR, IEEE 2030.5, IEC 60870-5-104, ICCP) with 5 core API primitives: connect, dispatch, settle, comply, and intel. Enables AI agents to programmatically interact with substations, grid interfaces, and energy assets for real-time workload-grid coordination.
Connect any AI agent to 1,000+ apps and 27,000+ actions through one remote MCP server (OAuth).
Automate 1,000+ services from any MCP-compatible AI agent: build Applets, run actions and queries.
Build and run AI workflows, agents, data tables and 1000+ API integrations from any MCP client.
Related MCP Servers
- AlicenseNot gradedqualityDmaintenanceConnects test and measurement instruments (oscilloscope, logic analyzer, multimeter, power supply) to AI via MCP, enabling natural language control and automated analysis.MIT
- AlicenseNot gradedqualityDmaintenanceEnables AI to measure DC voltage and waveform statistics from DreamSourceLab DSCope oscilloscopes via MCP tools.1MIT
- AlicenseNot gradedqualityCmaintenanceEnables MCP clients to connect to and control Siglent oscilloscopes and power supplies over SCPI/TCP using typed tool calls with input validation, safety controls, and built-in observability.1Apache 2.0
- AlicenseBqualityBmaintenanceEnables agentic measurement and control of a ChargerLab POWER-Z KM003C USB-C power meter, including live VBUS/IBUS sampling, USB PD capture and decoding, and fast-charge protocol triggering through MCP tools.18MIT