RackArchitect MCP
RackArchitect MCP lets an AI agent design, validate, and export a physically accurate rack build (19"/10"/6") from a single Git-friendly rack.yaml β no geometry guessing.
Discover hardware:
search_catalogfilters 67 blueprints by query, category, form factor, depth, slot type, or PoE budget;get_device_blueprintreturns full specs with millimeter port coordinates and carrier slot geometry.Extend the catalog:
define_custom_blueprintregisters unlisted gear (with ports, port grids, slots, power/thermal data) into session memory or a local YAML folder.Build the rack:
init_rackcreates/resets the enclosure (width standard, U height, rail depth, door/rear clearance);mount_equipmentplaces devices in a U slot or a modular carrier bay.Edit the build:
modify_equipmentmoves, renames, or removes instances (cascading cables), andundo_redowalks a 50-snapshot history.Wire it up:
connect_cablesupserts up to 128 cables with 3D Catmull-Rom splines, length bins, VLAN/IP annotations, and angled-plug variants;disconnect_cablesremoves by cable ID or device.Plan external drops:
plan_external_endpointsterminates building/room cabling on patch-panel rear ports and auto-patches labeled Cat6A links to a switch.Validate deterministically: every mutation and
validate_rackrun the 5-stage engine (bounds, 3D AABB/plug clearance/doors, power & PoE DAG, cable speed/bend radius, thermal/acoustic) and return structuredremediation_suggestionsfor self-correction.Export deliverables:
export_deliverableswrites elevation/wiring SVGs, BOM.md, binary GLB, and parametric OpenSCAD/watertight STL 3D-print files (or HTTPS download URLs on the hosted server).
Generates parametric OpenSCAD (.scad) carrier models and STL meshes for 3D-printed rack adapters and modular carriers.
ποΈ RackArchitect MCP (@rack-mcp/*)
The Open-Source, Agent-First "Rack-as-Code" Planning, 5-Stage Validation, Parametric 3D-Print (.scad/.stl) & Live 2D/3D CAD Platform for 19-Inch Enterprise Racks, 10-Inch Mini-Racks & 6-Inch Micro-Homelabs
β‘ Zero-Install Remote MCP (.../mcp) Β· π₯οΈ Hosted Live 3D Studio Β· π Static 3D Demo Β· Quickstart Β· Agent Skill Β· 3D-Print (.SCAD / .STL) Β· Add Blueprint Β· Handbook (DE)
β‘ Instant Zero-Install Remote MCP Endpoint (Live & Free β No Node.js or Docker Required):
Connect Claude, Claude Code, Cursor, VS Code Copilot, Windsurf, Google Antigravity, or MCP Inspector directly viahttps://mcp.rackarchitect.dev/mcp(Streamable HTTP) orhttps://mcp.rackarchitect.dev/sse(SSE) β every session automatically gets its own isolated real-time Live 3D Digital Twin URL (https://mcp.rackarchitect.dev/?session=<uuid>)!
π― Why RackArchitect MCP? (The Three Golden Laws)
Planning a compact 10-inch mini-rack (e.g., DeskPi RackMate T1/T2, Digitus SOHO) or a dense 19-inch homelab with AI agents used to fail for one reason: LLMs hallucinate physical geometry. They forget that a 55 mm Schuko plug on a rear PDU collides with a 182 mm Lenovo ThinkCentre M920q mounted in front, or that two fanless PoE switches stacked together create a thermal hotspot.
RackArchitect MCP solves this with three non-negotiable engineering laws:
LLMs Never Guess Geometry: Every spatial coordinate (
1 U = 44.45 mm), 3D Axis-Aligned Bounding Box (B_chassis+ dynamic plug clearance $\Delta Z_{\text{plug}}$), Catmull-Rom 3D cable spline, PoE budget DAG, and logarithmicdB(A)acoustic sum is computed deterministically in millimeters by@rack-mcp/core-domain.Single Source of Truth (
rack.yaml): Your entire rack state (devices, 3D-printed sub-U carrier slots, child mini-PCs, keystone couplers, cables, VLANs, and IP CIDRs) lives in a single, Git-friendly YAML file.Actionable Self-Correction Feedback: Whenever a placement or cable fails any of the 5 validation stages (26 closed
DiagnosticCodetypes), the engine returns structuredremediation_suggestionsso your AI agent fixes the collision, PoE overload, orCat5ebottleneck autonomously in the very next turn.
Related MCP server: techhand-print-fab
πΌοΈ Generated CAD Blueprints (100% Deterministic SVG Output)
1. Dual-Row Engineering Elevation & Z-Depth Side Cutaway (elevation.svg)
Includes Equipment Schedule, Front Elevation (X, Y), Horizontally Mirrored Rear Elevation (W_panel - X - width), Cable Callout Lanes, and Right-Hand Z-Depth Cutaway (Z_min to Z_max with Front Glass Door -50 mm and Rear Wall +300 mm clearance checks):
2. 5-Layer Logical Pin-to-Pin Wiring Schematic with VLAN & IP CIDR Badges (wiring-schematic.svg)
π 30-Second Quickstart
Option A: Zero-Install Hosted Remote MCP + Live 3D Studio (Recommended β 0 Setup!)
Use the live, multi-tenant Hosted Remote MCP server right away without installing Node.js, pnpm, or Docker:
{
"mcpServers": {
"rack_architect_mcp": {
"url": "https://mcp.rackarchitect.dev/mcp"
}
}
}# Or add in 1 second via Claude Code CLI:
claude mcp add --transport http rack_architect_mcp https://mcp.rackarchitect.dev/mcp
# Or explore the Hosted Live 3D/2D Studio directly in your browser:
# https://mcp.rackarchitect.dev/Option B: Local Node.js (>= 20) & pnpm
# 1. Clone & install
git clone https://github.com/itAlex240/rack-architect-mcp.git
cd rack-architect-mcp
pnpm install
# 2. Build all 6 packages & run all 52 Vitest suites
pnpm build
pnpm test
# 3. Launch the Live 3D/2D Web-Viewer & Sidecar on the 8U 10-Inch Reference Homelab
pnpm startOpen http://127.0.0.1:3100/ in your browser to inspect the 3D Digital Twin, mount devices from the Catalog Drawer, route 3D spline cables, and download .SCAD / .STL / .GLB / .SVG / BOM.md deliverables!
Option C: Self-Hosted Docker (Zero Local Node Dependencies)
# Build & run directly from GitHub in one step (bound to localhost):
docker build -t rack-architect-mcp https://github.com/itAlex240/rack-architect-mcp.git
docker run --rm -p 127.0.0.1:3100:3100 rack-architect-mcp
# Open http://127.0.0.1:3100/Option D: CLI Validation & Headless CAD Export
# Validate any rack.yaml and print the ASCII Elevation Plan + Diagnostics
pnpm validate:demo
# Export elevation.svg, wiring-schematic.svg, BOM.md, rack-scene.glb, and all .scad + .stl 3D-print carriers
pnpm export:demoπ€ Connect Claude Desktop, Claude Code, Cursor, VS Code, Windsurf, or Antigravity
Option 1: Zero-Install Hosted Remote MCP (Streamable HTTP & SSE β Instant 1-URL Setup)
Connect any MCP client directly over HTTPS β zero local dependencies, strict multi-session isolation, and an automatic real-time 3D browser twin for every AI session:
Live Hosted Endpoint | URL | Purpose |
Streamable HTTP MCP (Recommended) |
| Modern MCP transport ( |
Legacy HTTP+SSE MCP |
| Backwards-compatible |
Live Hosted 3D Studio & Session Twin |
| Interactive 3D/2D CAD Studio & live |
MCP Discovery & Health Probe |
| Machine-readable MCP discovery manifest & |
Standard mcp.json / Client Configuration (Streamable HTTP):
{
"mcpServers": {
"rack_architect_mcp": {
"url": "https://mcp.rackarchitect.dev/mcp"
}
}
}1-Line CLI & Inspector Commands:
# Claude Code CLI:
claude mcp add --transport http rack_architect_mcp https://mcp.rackarchitect.dev/mcp
# Test immediately in MCP Inspector:
npx @modelcontextprotocol/inspector https://mcp.rackarchitect.dev/mcpLegacy HTTP+SSE Configuration (for older SSE-only MCP clients):
{
"mcpServers": {
"rack_architect_mcp": {
"type": "sse",
"url": "https://mcp.rackarchitect.dev/sse"
}
}
}Strict Multi-Session Isolation & Zero-Disk Exports: Every connecting MCP client receives its own isolated in-memory workspace (
Mcp-Session-Id), a dedicated Live 3D Digital Twin URL (https://mcp.rackarchitect.dev/?session=<uuid>) streaming every AI tool mutation live overwss://, and direct HTTPS download URLs fromexport_deliverables(.svg,.md,.glb,.scad,.stl,.yaml).
Option 2: Local stdio + Local WebSocket Sidecar (127.0.0.1:3100)
Add rack_architect_mcp to your claude_desktop_config.json, .cursor/mcp.json, or Antigravity MCP settings:
{
"mcpServers": {
"rack_architect_mcp": {
"command": "node",
"args": [
"/ABSOLUTE/PATH/TO/rack-architect-mcp/packages/cli/dist/bin.js",
"--stdio",
"--port",
"3100",
"--project",
"/ABSOLUTE/PATH/TO/rack-architect-mcp/examples/10inch-homelab/rack.yaml"
]
}
}
}Whenever your AI agent starts the MCP server over stdio, it automatically launches the local WebSocket Sidecar at http://127.0.0.1:3100. Every tool call the AI executes (mount_equipment, connect_cables, modify_equipment, undo_redo) updates your 3D browser view in real time!
π§ Official Open-Source Agent Skill (skills/rack-architect/SKILL.md)
This repository includes a 100% free, MIT-licensed Agent Skill (skills/rack-architect/SKILL.md & .agents/skills/rack-architect/SKILL.md) that teaches Claude Code, Cursor, GitHub Copilot, and Google Antigravity the complete 6-Phase Autonomous Rack Engineering Runbook (sub-U modular carrier pairing, -angled plug selection, all 26 diagnostic remediation patterns, and 2-manifold .STL export):
# Install the skill into Claude Code, Cursor, Copilot, or Windsurf via skills CLI:
npx skills add itAlex240/rack-architect-mcp
# Or in Google Antigravity: automatically discovered from .agents/skills/rack-architect/SKILL.md!π¨οΈ Parametric 3D-Print Generator (.scad & .stl)
For every modular 3D-printed carrier (category: 'modular-carrier'), @rack-mcp/exporters automatically generates:
Parametric OpenSCAD (
.scad): Customizable wall thickness, EIA-310 oval rack ears (9.5 Γ 6.5 mm), sub-U device bays (+0.35 mmtolerance for Lenovo ThinkCentre M920q, Ubiquiti UCG-Max, JetKVM), Keystone snap-in clips, side support rails, and rear PSU brick cradles with Velcro slots.Ready-to-Slice Watertight ASCII
.stl: Computed directly in memory via 2D grid subdivisionβdrop straight into OrcaSlicer, Bambu Studio, or PrusaSlicer!
Pre-generated reference files in examples/10inch-homelab/:
π₯οΈ Live 3D Digital Twin & 2D CAD Web-Viewer (Hosted & Local :3100)
Interactive Catalog & Cable Patch Builder (
+ Catalog & Cable Builder):Search all 67 hardware blueprints, filter by
10inch/19inch/6inch/sub-module, selectTarget U+FRONT/REAR, and mount with 1 click.Patch 3D Catmull-Rom cables between any two ports with optional
VLAN ID(1..4094) andIP CIDR(10.10.20.0/24) annotations.
3D Engineering HUD:
Camera Presets:
Perspective,Front Ortho,Rear Ortho,Left CutawayToggles:
X-Ray Chassis(inspect internal mini-PCs & PSU bricks),Clearance Boxes($\Delta Z_{\text{plug}}$ wireframes),Cable SplinesExplode Z (0..140 mm)slider to separate front and rear assemblies
W3C WebMCP Ready: Automatically registers all 12 tools on
document.modelContextwhen opened in a WebMCP-capable browser.
π‘οΈ 5-Stage Validation Engine (All 26 Diagnostic Codes)
Stage | Diagnostic Codes | What Is Checked Deterministically? |
1. Bounds & Slots |
| Rack U height, panel width ( |
2. 3D AABB & Doors |
| Millimeter-exact 3D AABB overlap between front and rear equipment including dynamic plug clearances ( |
3. Power & PoE DAG |
| Full electrical DAG from UPS/PDU to switches, external power bricks (Lenovo 135W Slim-Tip), and PoE PSE/PD budgets ( |
4. Cables & Speed |
| Connector compatibility, |
5. Thermal & Acoustic |
| Opposing airflow ( |
π¦ Monorepo Architecture (packages/*)
Package | Description |
Pure TypeScript/Zod schemas, 3D coordinate transformer, AABB collision solver, 5-stage validator, and clamped Catmull-Rom 3D spline router (zero Node/DOM dependencies). | |
67 YAML hardware blueprints ( | |
| |
Multi-tenant Remote MCP server ( | |
React 19 + Three.js ( | |
Unified |
π€ Contributing & Adding Hardware Blueprints
Want to add your favorite 10-inch switch, mini-PC, or 3D-printed carrier? You can add a new YAML blueprint in under 2 minutesβsee CONTRIBUTING.md!
π License
Released under the MIT License.
Available Tools
12 toolsconnect_cablesConnect and Route Inter-Device CablesAIdempotent
Connect or update a batch of up to 128 power and network cables between mounted device ports in the active rack, computing 3D Catmull-Rom splines, commercial length bins, and PoE or power budgets. Each entry in 'cables[]' upserts in place by 'cable_id' while leaving all other cables and mounted equipment untouched, pushes a recoverable undo snapshot, and persists rack.yaml atomically; port, speed, PoE, or clearance violations return status 'INVALID' with remediation_suggestions instead of throwing. Within each cable, endpoint 'face' is required only on pass-through couplers such as patch panels exposing identical 'port_id' values on both faces, 'preferred_portal_u' applies only to front-to-rear transitions, and 'vlan_id' or 'ip_cidr' annotate logical network links. Use when both endpoint devices are mounted inside the rack; use disconnect_cables to remove cables, or plan_external_endpoints to terminate incoming building cable drops on a patch panel.
Inputs: cables (required). Returns: data, issues, status, summary
define_custom_blueprintRegister Custom Hardware BlueprintAIdempotent
Validate and register a custom hardware blueprint into the active catalog so unlisted equipment can be mounted. Pass the entire specification inside the top-level 'blueprint' object: 'blueprint.slug' must use lowercase kebab-case, ports may combine explicit 'ports[]' with repeating 'port_groups[]' macros whose coordinates fit strictly within 'blueprint.geometry' without overlapping, and 'slots[]' applies only when 'mount_type' is 'modular-carrier' whereas 'slot_compatibility' applies to 'sub-module'. Persists YAML to the local custom-catalog folder in stdio mode or session memory on remote servers, overwrites same-slug custom entries without touching mounted rack state or undo history, and returns status 'INVALID' instead of throwing on validation errors. Use only after search_catalog confirms hardware is unlisted; use mount_equipment instead to place an already registered blueprint into the rack.
Inputs: blueprint (required). Returns: data, issues, status, summary
disconnect_cablesDisconnect Cables by ID or Device InstanceADestructiveIdempotent
Remove specific cables by identifier or strip all cables attached to a mounted device or modular carrier from the active rack, then re-evaluate PoE budgets and plug clearances. Supply a non-empty 'cable_ids' list, 'instance_id', or both to disconnect their union; 'instance_id' matches both 'from' and 'to' endpoints across a carrier and its child sub-modules while leaving external patch-panel drops intact, whereas omitting both or passing only an empty list returns status 'INVALID' with a PORT_NOT_FOUND issue and zero mutations. Valid calls push an undo snapshot, persist rack.yaml atomically, and return removed IDs, remaining cable count, and updated validation results, succeeding idempotently when targeted IDs are already absent. Use when rewiring ports while keeping hardware mounted; use connect_cables to add or replace cables, or modify_equipment with action 'remove' to delete a device and its cables.
Inputs: cable_ids, instance_id. Returns: data, issues, status, summary
export_deliverablesExport 2D SVG, BOM, 3D GLB, and 3D-Print DeliverablesADestructiveIdempotent
Generate 2D elevation and wiring SVGs, a Markdown BOM, a binary 3D GLB scene, and parametric OpenSCAD or watertight STL 3D-print models for the active rack project. Omitting 'formats' exports all six types; 'carrier-scad' and 'carrier-stl' emit one file per mounted modular carrier, switch cradle, or printable cover panel and emit zero files when none are mounted, while 'output_dir' resolves relative paths within the project directory and creates missing folders. Local stdio execution writes deterministic filenamesβelevation.svg, wiring-schematic.svg, BOM.md, rack-scene.glb, and .scad or .stlβoverwriting same-named files in place, whereas hosted remote sessions stream in-memory HTTPS download URLs; neither mode mutates rack state or undo history. Use after validate_rack confirms a valid layout; use validate_rack instead for read-only validation and ASCII elevation inspection without generating export files.
Inputs: formats, output_dir. Returns: data, issues, status, summary
get_device_blueprintRetrieve Hardware Device Blueprint DetailsARead-onlyIdempotent
Retrieve the complete hardware specification, millimeter port coordinates, electrical and PoE ratings, and carrier slot geometry for a single catalog blueprint. The 'slug' parameter requires a case-sensitive exact match in lowercase kebab-case vendor-model-variant format against the built-in or session custom catalog; partial substrings or uppercase characters do not match. Returns the full blueprint in one unpaginated payload with repeating port_groups pre-expanded into up to 256 flat ports[] entries, or returns status 'INVALID' with a BLUEPRINT_NOT_FOUND issue and candidate slugs instead of throwing. Use when you already know the target slug and need exact port_id or slot_id values for mount_equipment or connect_cables; use search_catalog instead to discover unknown slugs by criteria.
Inputs: slug (required). Returns: data, issues, status, summary
init_rackInitialize and Reset Rack EnclosureADestructiveIdempotent
Initialize a new rack project and destructively reset the active rack.yaml state to an empty enclosure with the specified width standard, U height, and rail depth. Overwrites the current enclosure and clears all mounted devices, child sub-modules, cables, and external endpoints, while pushing the previous project state onto the in-memory undo stack for recovery via undo_redo. 'project_name' sets the title used in exported schematics and BOMs, 'rail_depth_mm' plus 'rear_clearance_mm' bounds total +Z chassis and rear plug depth before wall collision, and 'front_door_clearance_mm' is enforced only when 'enclosure_type' has a closed front door. Use when starting a rack design from scratch or changing enclosure dimensions; use validate_rack to inspect the current rack, or modify_equipment to move or remove individual devices.
Inputs: standard (required), u_height (required), rail_depth_mm (required), project_name, +3 more. Returns: data, issues, status, summary
modify_equipmentMove, Rename, or Remove Mounted EquipmentADestructive
Move, rename, or destructively remove an existing mounted device or child sub-module in the active rack, recalculate 3D cable splines, and re-run 5-stage validation. 'instance_id' resolves across top-level devices and carrier sub-modules, and required fields depend on 'action': 'move' updates 'u_position' and 'face' on rackmount gear or 'slot_id' and optional 'parent_carrier_id' across carriers for sub-modules with primary fields taking precedence over 'new_*' aliases, 'rename' updates or clears 'hostname', and 'remove' cascades to child sub-modules plus attached cables and external endpoints when 'remove_connected_cables' is true. Pushes the prior state onto the undo stack and updates rack.yaml atomically, or returns status 'INVALID' without mutating state when 'instance_id' or a target carrier is unknown. Use to update or delete a mounted instance; use mount_equipment to add new hardware, or disconnect_cables to remove cables while keeping devices mounted.
Inputs: action (required), instance_id (required), face, slot_id, +7 more. Returns: data, issues, status, summary
mount_equipmentMount Equipment into Rack Unit or Carrier SlotA
Mount a new hardware device instance onto a rack unit or into a modular carrier bay in the active rack.yaml project and run 5-stage validation. 'instance_id' must be unique across both top-level devices and nested sub-modules, 'blueprint_slug' must reference an existing catalog or custom slug, and placement uses two mutually exclusive modes: 'u_position' with optional 'face' where the device's full U span fits within 1..u_height, or 'parent_carrier_id' plus a compatible 'slot_id' for sub-modules. Precondition errors such as duplicate 'instance_id', unknown 'blueprint_slug', or missing carriers return status 'INVALID' without mutating state, whereas 3D collision or PoE issues persist the mount, push an undo snapshot, and return remediation_suggestions. Use to add a new device instance; use modify_equipment to move, rename, or remove an existing instance, or plan_external_endpoints for off-rack room cable drops.
Inputs: instance_id (required), blueprint_slug (required), face, slot_id, +3 more. Returns: data, issues, status, summary
plan_external_endpointsTerminate External Building Cable Drops on Patch PanelADestructive
Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops firstβwith 'custom_labels[]' overriding numbered 'label_prefix' entries per indexβfollowed by 'endpoints[]', allocating sequential free rear ports from 'start_port_number' and sequential free switch RJ45 ports from 'auto_connect_switch_start_port'. Setting 'clear_existing' destructively removes prior external drops on 'patch_panel_instance_id' and their front patch cables before allocation, while unmounted patch-panel or switch IDs return status 'INVALID' without mutating state. Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.
Inputs: patch_panel_instance_id (required), groups, endpoints, clear_existing, +4 more. Returns: data, issues, status, summary
search_catalogSearch Hardware Blueprint CatalogARead-onlyIdempotent
Search and filter the local hardware catalog to discover compatible rackmount devices, modular carriers, and sub-modules before mounting. All supplied filters combine with logical AND: 'form_factor' and its alias 'mount_type' accept width shorthands '10inch', '19inch', and '6inch' that match both direct rackmount gear and modular carriers, 'accepted_slot_type' matches both carrier bays and compatible sub-modules, and 'max_depth_mm' bounds chassis depth excluding plug clearance. Returns all matches from the bounded catalog in one unpaginated response sorted in deterministic registration order, with built-in blueprints followed by custom blueprints. Call with no arguments to list the full catalog; use get_device_blueprint to inspect expanded port coordinates for a known slug, or define_custom_blueprint to register unlisted hardware.
Inputs: query, category, mount_type, form_factor, +3 more. Returns: data, issues, status, summary
undo_redoUndo or Redo Rack State MutationA
Traverse the per-project in-memory history ring buffer of up to 50 snapshots to revert the latest rack mutation or reapply a reverted mutation, updating rack.yaml atomically. Setting 'action' to 'undo' steps backward across rack-state mutationsβexcluding catalog-only define_custom_blueprint calls and read-only toolsβand pushes the displaced state onto the redo stack, whereas 'redo' is available only immediately after 'undo' because any new rack mutation flushes the redo stack. Calling either action when its target stack is empty is a safe no-op returning applied=false without throwing. Use to roll back an unintended batch change or accidental init_rack reset; use modify_equipment or disconnect_cables instead to edit specific items without reverting intermediate steps.
Inputs: action (required). Returns: data, issues, status, summary
validate_rackInspect and Validate Active Rack StateARead-onlyIdempotent
Inspect the active rack.yaml state and run all 5 deterministic validation stages covering mechanical bounds, 3D depth and plug clearances, PoE and power budgets, cable compatibility, and thermal limits. Takes no parameters, performs zero state or undo-stack mutations, and returns the ASCII front and rear elevation diagram, power utilization summary, and all diagnostic issues with remediation_suggestions. Sets status to 'INVALID' instead of throwing whenever any validation ERROR is present. Use to inspect currently mounted equipment or verify zero errors before exporting; use export_deliverables instead to generate SVG, BOM, GLB, or 3D-print files.
Inputs: no named parameters. Returns: data, issues, status, summary
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelogβ¦
TDQS
Scored across 12 tools
Each tool has a clearly distinct purpose, and descriptions explicitly cross-reference alternatives such as mount vs. modify, connect vs. disconnect, and validate vs. export. Overlapping-sounding operations like removing a device versus disconnecting cables are sharply separated.
All tool names use snake_case and follow a predictable verb_noun or verb_object pattern. The only slight outlier, undo_redo, is a conventional paired-action name and does not disrupt the pattern.
Twelve tools is well-scoped for a rack design server covering initialization, catalog management, mounting, cabling, validation, export, and undo. Each tool appears to earn its place without excessive surface area.
The surface covers the core rack lifecycle: init, catalog discovery and registration, mount/modify, cable operations, external endpoints, validation, export, and undo. Minor gaps exist, such as no dedicated read-only list/get mounted devices tool and no explicit custom-blueprint deletion, but agents can work around these via validate_rack and catalog behavior.
Maintenance
Related MCP Connectors
Parametric CAD as code: model 3D-printable parts on an exact B-rep kernel, measured.
Parametric 3D CAD for AI agents: build print-ready parts, check them, export STL, 3MF or STEP.
Text-to-CAD: build exact STEP or 3MF/STL on the server, each stated requirement measured.
AI network lab: build and validate real multi-vendor router and switch labs from a prompt.
Related MCP Servers
- AlicenseAqualityCmaintenanceDeterministic AI data-center design tools for sizing, validation, and conceptual rack/site layouts. Supports NVIDIA Hopper, Blackwell, and Rubin profiles. Calculations require a registered AIDC API key; results preserve warnings, RFIs, and pending validations.33MIT
- AlicenseAqualityBmaintenanceEnables generating parametric 3D-printable parts from OpenSCAD/CadQuery models, exporting STL/3MF files, running DFM checks, and retrieving Bambu X1 Carbon starting profile notes.8MIT
- AlicenseNot gradedqualityBmaintenanceEnables AI agents to design, modify, and verify exact B-rep 3D CAD models by running build123d scripts on an OpenCascade kernel, with live three.js preview, collision and FDM printability checks, text-based spatial perception, user notes/sketch annotations, version history, and one-click export to OrcaSlicer.1MIT
- AlicenseAqualityAmaintenanceFloor plans as code. Your AI writes ArchLang; the compiler draws a precise, dimensioned plan and tells it what's wrong.112,954 npm81MIT