Terminate External Building Cable Drops on Patch Panel

plan_external_endpoints
Destructive

Plan external building or room cable drops on the rear RJ45 ports of a mounted patch panel without using rack U slots, and optionally auto-create labeled Cat6A front patch cables to a switch.

Instructions

Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops first—with 'custom_labels[]' overriding numbered 'label_prefix' entries per index—followed by 'endpoints[]', allocating sequential free rear ports from 'start_port_number' and sequential free switch RJ45 ports from 'auto_connect_switch_start_port'. Setting 'clear_existing' destructively removes prior external drops on 'patch_panel_instance_id' and their front patch cables before allocation, while unmounted patch-panel or switch IDs return status 'INVALID' without mutating state. Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "patch_panel_instance_id": "<patch_panel_instance_id>"
    },
    "name": "plan_external_endpoints"
  }
}

Input Schema

NameRequiredDescriptionDefault
groupsNoBatch groups of external drops (e.g., 10x PoE cameras, 5x Wi-Fi APs, 5x room LAN outlets).
endpointsNoIndividual external building/room drops to terminate on the rear of the patch panel.
clear_existingNoIf true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning.
entry_positionNoRear building cable conduit entry point into the rack frame.top-rear
start_port_numberNo1-indexed starting port number on the patch panel (defaults to next free rear port or 1).
patch_panel_instance_idYesMounted patch panel instance_id whose rear ports receive the incoming building cable drops.
auto_connect_switch_start_portNo1-indexed starting Ethernet port number on auto_connect_switch_instance_id (e.g., 1 for eth1).
auto_connect_switch_instance_idNoOptional switch instance_id to automatically patch from the front of the patch panel using labeled Cat6A cables.

Output Schema

NameRequiredDescriptionDefault
dataYesExternal endpoint planning and auto-patching payload.
issuesYesStructured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions.
statusYesDeterministic execution outcome: "VALID" when the operation succeeded with 0 validation errors; "INVALID" when precondition or engineering validation errors are present in issues[].
summaryYesConcise human- and agent-readable summary of the tool result and validation status.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed11 schema fields changedv0.7.8
    • addedInput schema / properties / auto_connect_switch_instance_id / maxLength
      Added value: +100
    • changedInput schema / properties / auto_connect_switch_start_port / maximum
      Previous value: -9007199254740991New value: +256
    • addedInput schema / properties / endpoints / items / properties / endpoint_id / maxLength
      Added value: +100
    • addedInput schema / properties / endpoints / items / properties / label / maxLength
      Added value: +200
    • addedInput schema / properties / endpoints / items / properties / notes / maxLength
      Added value: +1000
    • addedInput schema / properties / endpoints / items / properties / patch_panel_port_id / maxLength
      Added value: +128
    • addedInput schema / properties / endpoints / items / properties / poe_draw_watts / maximum
      Added value: +200
    • addedInput schema / properties / endpoints / items / properties / room_or_zone / maxLength
      Added value: +160
    • addedInput schema / properties / groups / items / properties / poe_draw_watts / maximum
      Added value: +200
    • addedInput schema / properties / patch_panel_instance_id / maxLength
      Added value: +100
    • changedInput schema / properties / start_port_number / maximum
      Previous value: -9007199254740991New value: +256
  2. Changed9 schema fields changedv0.5.0
    • addedInput schema / properties / endpoints / maxItems
      Added value: +128
    • changedInput schema / properties / groups / items / properties / count / description
      Previous value: -"Number of external cable drops in this group."New value: +"Number of external cable drops in this group (1..96)."
    • changedInput schema / properties / groups / items / properties / count / maximum
      Previous value: -9007199254740991New value: +96
    • addedInput schema / properties / groups / items / properties / custom_labels / items / maxLength
      Added value: +200
    • addedInput schema / properties / groups / items / properties / custom_labels / maxItems
      Added value: +96
    • addedInput schema / properties / groups / items / properties / id_prefix / maxLength
      Added value: +64
    • addedInput schema / properties / groups / items / properties / label_prefix / maxLength
      Added value: +160
    • addedInput schema / properties / groups / items / properties / room_or_zone / maxLength
      Added value: +160
    • addedInput schema / properties / groups / maxItems
      Added value: +24
  3. Changed2 schema fields changedv0.4.10
    • changedInput schema / properties / clear_existing / description
      Previous value: -"If true, clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning."New value: +"If true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning."
    • changedOutput schema / (root)
      Previous value: -nullNew value: +{
      +  "$schema": "http://json-schema.org/draft-07/schema#",
      +  "additionalProperties": false,
      +  "properties": {
      +    "data": {
      +      "additionalProperties": {},
      +      "description": "External endpoint planning and auto-patching payload.",
      +      "properties": {
      +        "added_endpoints_count": {
      +          "description": "Number of external building/room cable drops terminated on the patch panel rear ports.",
      +          "maximum": 9007199254740991,
      +          "minimum": 0,
      +          "type": "integer"
      +        },
      +        "auto_connect_switch_instance_id": {
      +          "description": "Target auto_connect_switch_instance_id echoed when a pre-check fails.",
      +          "type": "string"
      +        },
      +        "auto_patched_cables_count": {
      +          "description": "Number of front Cat6A patch cables automatically created to the target switch.",
      +          "maximum": 9007199254740991,
      +          "minimum": 0,
      +          "type": "integer"
      +        },
      +        "patch_panel_instance_id": {
      +          "description": "Target patch_panel_instance_id echoed when a pre-check fails.",
      +          "type": "string"
      +        },
      +        "patching_guide": {
      +          "description": "Step-by-step rear punchdown and front switch patching schedule.",
      +          "items": {
      +            "additionalProperties": {},
      +            "properties": {
      +              "color_hex": {
      +                "description": "Assigned cable hex color code.",
      +                "type": "string"
      +              },
      +              "endpoint_id": {
      +                "description": "Unique external endpoint identifier.",
      +                "type": "string"
      +              },
      +              "front_patch_cable": {
      +                "description": "Front patch panel to switch port assignment.",
      +                "type": "string"
      +              },
      +              "label": {
      +                "description": "Human-readable room or device drop label.",
      +                "type": "string"
      +              },
      +              "poe_draw_watts": {
      +                "description": "PoE power draw in watts for this drop.",
      +                "minimum": 0,
      +                "type": "number"
      +              },
      +              "rear_punchdown": {
      +                "description": "Rear patch panel port termination assignment.",
      +                "type": "string"
      +              },
      +              "room_or_zone": {
      +                "description": "Building zone or room name.",
      +                "type": "string"
      +              },
      +              "step_number": {
      +                "description": "Sequential installation step number.",
      +                "exclusiveMinimum": 0,
      +                "maximum": 9007199254740991,
      +                "type": "integer"
      +              }
      +            },
      +            "required": [
      +              "step_number",
      +              "endpoint_id",
      +              "label",
      +              "room_or_zone",
      +              "poe_draw_watts",
      +              "rear_punchdown",
      +              "front_patch_cable",
      +              "color_hex"
      +            ],
      +            "type": "object"
      +          },
      +          "type": "array"
      +        },
      +        "total_external_endpoints": {
      +          "description": "Total external endpoints now configured in the rack project.",
      +          "maximum": 9007199254740991,
      +          "minimum": 0,
      +          "type": "integer"
      +        },
      +        "validation": {
      +          "additionalProperties": false,
      +          "description": "Updated 5-stage validation report including cumulative PoE load from external building drops.",
      +          "properties": {
      +            "error_count": {
      +              "description": "Total number of blocking ERROR diagnostics.",
      +              "maximum": 9007199254740991,
      +              "minimum": 0,
      +              "type": "integer"
      +            },
      +            "is_valid": {
      +              "description": "True when zero ERROR-level diagnostic issues exist.",
      +              "type": "boolean"
      +            },
      +            "issues": {
      +              "description": "List of all detected ERROR, WARNING, and INFO diagnostic issues.",
      +              "items": {
      +                "additionalProperties": false,
      +                "description": "Single validation finding with deterministic self-correction feedback.",
      +                "properties": {
      +                  "affected_instances": {
      +                    "description": "Device instance IDs involved in this diagnostic issue.",
      +                    "items": {
      +                      "type": "string"
      +                    },
      +                    "type": "array"
      +                  },
      +                  "code": {
      +                    "description": "Machine-readable deterministic validation diagnostic code.",
      +                    "enum": [
      +                      "CHASSIS_COLLISION",
      +                      "PLUG_CLEARANCE_COLLISION",
      +                      "FRONT_DOOR_COLLISION",
      +                      "SLOT_DIMENSION_OVERFLOW",
      +                      "SLOT_INCOMPATIBLE",
      +                      "OUT_OF_RACK_BOUNDS",
      +                      "BLUEPRINT_NOT_FOUND",
      +                      "PORT_NOT_FOUND",
      +                      "PORT_ALREADY_OCCUPIED",
      +                      "CONNECTOR_INCOMPATIBLE",
      +                      "SIGNAL_PROTOCOL_INCOMPATIBLE",
      +                      "SPEED_MISMATCH",
      +                      "POE_BUDGET_EXCEEDED",
      +                      "POE_CLASS_EXCEEDED",
      +                      "UPS_OVERLOAD",
      +                      "UNPOWERED_DEVICE",
      +                      "TOP_HEAVY_RACK",
      +                      "NO_FRONT_TO_REAR_PORTAL",
      +                      "THERMAL_AIRFLOW_CONFLICT",
      +                      "THERMAL_HOTSPOT_STACKING",
      +                      "ACOUSTIC_NOISE_HIGH"
      +                    ],
      +                    "type": "string"
      +                  },
      +                  "message": {
      +                    "description": "Detailed engineering explanation with exact millimeter/watt figures.",
      +                    "type": "string"
      +                  },
      +                  "remediation_actions": {
      +                    "description": "Optional machine-actionable remediation descriptors.",
      +                    "items": {
      +                      "additionalProperties": false,
      +                      "description": "Structured self-correction action for autonomous agent remediation.",
      +                      "properties": {
      +                        "action_type": {
      +                          "description": "Recommended self-correction operation category.",
      +                          "enum": [
      +                            "move_device",
      +                            "change_cable_type",
      +                            "connect_power",
      +                            "disconnect_cable",
      +                            "redistribute_poe",
      +                            "add_portal_gap",
      +                            "change_rack_depth"
      +                          ],
      +                          "type": "string"
      +                        },
      +                        "description": {
      +                          "description": "Human- and agent-readable explanation of the remediation step.",
      +                          "type": "string"
      +                        },
      +                        "suggested_cable_type": {
      +                          "description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade).",
      +                          "type": "string"
      +                        },
      +                        "suggested_face": {
      +                          "description": "Mounting or port face relative to the rack or chassis.",
      +                          "enum": [
      +                            "front",
      +                            "rear"
      +                          ],
      +                          "type": "string"
      +                        },
      +                        "suggested_u_positions": {
      +                          "description": "Candidate 1-indexed U positions that resolve the spatial conflict.",
      +                          "items": {
      +                            "exclusiveMinimum": 0,
      +                            "maximum": 9007199254740991,
      +                            "type": "integer"
      +                          },
      +                          "type": "array"
      +                        },
      +                        "target_cable_id": {
      +                          "description": "Cable connection cable_id targeted by this remediation action.",
      +                          "type": "string"
      +                        },
      +                        "target_instance_id": {
      +                          "description": "Device instance_id targeted by this remediation action.",
      +                          "type": "string"
      +                        }
      +                      },
      +                      "required": [
      +                        "action_type",
      +                        "description"
      +                      ],
      +                      "type": "object"
      +                    },
      +                    "type": "array"
      +                  },
      +                  "remediation_suggestions": {
      +                    "description": "Actionable self-correction instructions for the calling LLM agent.",
      +                    "items": {
      +                      "type": "string"
      +                    },
      +                    "minItems": 1,
      +                    "type": "array"
      +                  },
      +                  "severity": {
      +                    "description": "Severity level of the engineering constraint diagnostic.",
      +                    "enum": [
      +                      "ERROR",
      +                      "WARNING",
      +                      "INFO"
      +                    ],
      +                    "type": "string"
      +                  },
      +                  "stage": {
      +                    "description": "Validation pipeline stage (1..5) that produced this finding.",
      +                    "maximum": 5,
      +                    "minimum": 1,
      +                    "type": "integer"
      +                  },
      +                  "u_range": {
      +                    "additionalItems": false,
      +                    "description": "Inclusive [start_u, end_u] range where the issue occurs.",
      +                    "items": [
      +                      {
      +                        "maximum": 9007199254740991,
      +                        "minimum": -9007199254740991,
      +                        "type": "integer"
      +                      },
      +                      {
      +                        "maximum": 9007199254740991,
      +                        "minimum": -9007199254740991,
      +                        "type": "integer"
      +                      }
      +                    ],
      +                    "maxItems": 2,
      +                    "minItems": 2,
      +                    "type": "array"
      +                  }
      +                },
      +                "required": [
      +                  "code",
      +                  "severity",
      +                  "affected_instances",
      +                  "message",
      +                  "remediation_suggestions"
      +                ],
      +                "type": "object"
      +              },
      +              "type": "array"
      +            },
      +            "mechanical_summary": {
      +              "additionalProperties": false,
      +              "description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
      +              "properties": {
      +                "airflow_profile": {
      +                  "default": "uniform-passive",
      +                  "description": "Rack-wide thermal airflow regime classification.",
      +                  "enum": [
      +                    "uniform-front-to-rear",
      +                    "uniform-passive",
      +                    "hybrid-active-passive",
      +                    "mixed-conflict"
      +                  ],
      +                  "type": "string"
      +                },
      +                "available_portal_u_positions": {
      +                  "description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel).",
      +                  "items": {
      +                    "maximum": 9007199254740991,
      +                    "minimum": -9007199254740991,
      +                    "type": "integer"
      +                  },
      +                  "type": "array"
      +                },
      +                "center_of_gravity_y_mm": {
      +                  "description": "Vertical Center of Gravity height from bottom of U1 in millimeters.",
      +                  "type": "number"
      +                },
      +                "combined_noise_db_a": {
      +                  "default": 0,
      +                  "description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices.",
      +                  "type": "number"
      +                },
      +                "normalized_cog_y": {
      +                  "description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50).",
      +                  "type": "number"
      +                },
      +                "total_thermal_btu_hr": {
      +                  "default": 0,
      +                  "description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr).",
      +                  "type": "number"
      +                },
      +                "total_weight_grams": {
      +                  "description": "Total mass of all mounted equipment in grams.",
      +                  "type": "number"
      +                }
      +              },
      +              "required": [
      +                "total_weight_grams",
      +                "center_of_gravity_y_mm",
      +                "normalized_cog_y",
      +                "available_portal_u_positions",
      +                "total_thermal_btu_hr",
      +                "combined_noise_db_a",
      +                "airflow_profile"
      +              ],
      +              "type": "object"
      +            },
      +            "power_summary": {
      +              "additionalProperties": false,
      +              "description": "Aggregated electrical and PoE DAG power analysis.",
      +              "properties": {
      +                "power_sources": {
      +                  "description": "Per-PDU and per-UPS electrical load breakdown.",
      +                  "items": {
      +                    "additionalProperties": false,
      +                    "description": "Load and capacity summary for a mounted PDU or UPS unit.",
      +                    "properties": {
      +                      "capacity_watts": {
      +                        "description": "Maximum rated output capacity of the power source in watts.",
      +                        "type": "number"
      +                      },
      +                      "role": {
      +                        "description": "Electrical source classification (\"pdu\" or \"ups\").",
      +                        "enum": [
      +                          "pdu",
      +                          "ups"
      +                        ],
      +                        "type": "string"
      +                      },
      +                      "source_instance_id": {
      +                        "description": "Instance ID of the upstream PDU or UPS unit.",
      +                        "type": "string"
      +                      },
      +                      "total_load_watts": {
      +                        "description": "Cumulative downstream system and PoE load in watts.",
      +                        "type": "number"
      +                      },
      +                      "utilization_percent": {
      +                        "description": "Percentage of rated watt capacity consumed (0..100+).",
      +                        "type": "number"
      +                      }
      +                    },
      +                    "required": [
      +                      "source_instance_id",
      +                      "role",
      +                      "capacity_watts",
      +                      "total_load_watts",
      +                      "utilization_percent"
      +                    ],
      +                    "type": "object"
      +                  },
      +                  "type": "array"
      +                },
      +                "pse_budgets": {
      +                  "description": "Per-switch PoE budget utilization breakdown.",
      +                  "items": {
      +                    "additionalProperties": false,
      +                    "description": "PoE budget utilization breakdown for a single PSE switch.",
      +                    "properties": {
      +                      "consumed_poe_watts": {
      +                        "description": "Total PoE power drawn by connected Powered Devices (PDs) in watts.",
      +                        "type": "number"
      +                      },
      +                      "downstream_devices": {
      +                        "description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch.",
      +                        "items": {
      +                          "type": "string"
      +                        },
      +                        "type": "array"
      +                      },
      +                      "poe_budget_watts": {
      +                        "description": "Maximum rated PoE output power budget of the switch in watts.",
      +                        "type": "number"
      +                      },
      +                      "pse_instance_id": {
      +                        "description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch.",
      +                        "type": "string"
      +                      },
      +                      "remaining_poe_watts": {
      +                        "description": "Remaining available PoE power budget in watts (negative if overloaded).",
      +                        "type": "number"
      +                      }
      +                    },
      +                    "required": [
      +                      "pse_instance_id",
      +                      "poe_budget_watts",
      +                      "consumed_poe_watts",
      +                      "remaining_poe_watts",
      +                      "downstream_devices"
      +                    ],
      +                    "type": "object"
      +                  },
      +                  "type": "array"
      +                },
      +                "total_poe_watts": {
      +                  "description": "Total PoE power draw across all connected PoE devices and external drops in watts.",
      +                  "type": "number"
      +                },
      +                "total_system_watts": {
      +                  "description": "Total peak system power draw across all mounted equipment in watts.",
      +                  "type": "number"
      +                },
      +                "unpowered_active_instances": {
      +                  "description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input.",
      +                  "items": {
      +                    "type": "string"
      +                  },
      +                  "type": "array"
      +                }
      +              },
      +              "required": [
      +                "total_system_watts",
      +                "total_poe_watts",
      +                "pse_budgets",
      +                "power_sources",
      +                "unpowered_active_instances"
      +              ],
      +              "type": "object"
      +            },
      +            "status": {
      +              "description": "Overall rack validation state (\"VALID\" when error_count is 0).",
      +              "enum": [
      +                "VALID",
      +                "INVALID"
      +              ],
      +              "type": "string"
      +            },
      +            "warning_count": {
      +              "description": "Total number of non-blocking WARNING diagnostics.",
      +              "maximum": 9007199254740991,
      +              "minimum": 0,
      +              "type": "integer"
      +            }
      +          },
      +          "required": [
      +            "status",
      +            "is_valid",
      +            "error_count",
      +            "warning_count",
      +            "issues",
      +            "power_summary",
      +            "mechanical_summary"
      +          ],
      +          "type": "object"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "issues": {
      +      "description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions.",
      +      "items": {
      +        "additionalProperties": false,
      +        "description": "Single validation finding with deterministic self-correction feedback.",
      +        "properties": {
      +          "affected_instances": {
      +            "description": "Device instance IDs involved in this diagnostic issue.",
      +            "items": {
      +              "type": "string"
      +            },
      +            "type": "array"
      +          },
      +          "code": {
      +            "description": "Machine-readable deterministic validation diagnostic code.",
      +            "enum": [
      +              "CHASSIS_COLLISION",
      +              "PLUG_CLEARANCE_COLLISION",
      +              "FRONT_DOOR_COLLISION",
      +              "SLOT_DIMENSION_OVERFLOW",
      +              "SLOT_INCOMPATIBLE",
      +              "OUT_OF_RACK_BOUNDS",
      +              "BLUEPRINT_NOT_FOUND",
      +              "PORT_NOT_FOUND",
      +              "PORT_ALREADY_OCCUPIED",
      +              "CONNECTOR_INCOMPATIBLE",
      +              "SIGNAL_PROTOCOL_INCOMPATIBLE",
      +              "SPEED_MISMATCH",
      +              "POE_BUDGET_EXCEEDED",
      +              "POE_CLASS_EXCEEDED",
      +              "UPS_OVERLOAD",
      +              "UNPOWERED_DEVICE",
      +              "TOP_HEAVY_RACK",
      +              "NO_FRONT_TO_REAR_PORTAL",
      +              "THERMAL_AIRFLOW_CONFLICT",
      +              "THERMAL_HOTSPOT_STACKING",
      +              "ACOUSTIC_NOISE_HIGH"
      +            ],
      +            "type": "string"
      +          },
      +          "message": {
      +            "description": "Detailed engineering explanation with exact millimeter/watt figures.",
      +            "type": "string"
      +          },
      +          "remediation_actions": {
      +            "description": "Optional machine-actionable remediation descriptors.",
      +            "items": {
      +              "additionalProperties": false,
      +              "description": "Structured self-correction action for autonomous agent remediation.",
      +              "properties": {
      +                "action_type": {
      +                  "description": "Recommended self-correction operation category.",
      +                  "enum": [
      +                    "move_device",
      +                    "change_cable_type",
      +                    "connect_power",
      +                    "disconnect_cable",
      +                    "redistribute_poe",
      +                    "add_portal_gap",
      +                    "change_rack_depth"
      +                  ],
      +                  "type": "string"
      +                },
      +                "description": {
      +                  "description": "Human- and agent-readable explanation of the remediation step.",
      +                  "type": "string"
      +                },
      +                "suggested_cable_type": {
      +                  "description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade).",
      +                  "type": "string"
      +                },
      +                "suggested_face": {
      +                  "description": "Mounting or port face relative to the rack or chassis.",
      +                  "enum": [
      +                    "front",
      +                    "rear"
      +                  ],
      +                  "type": "string"
      +                },
      +                "suggested_u_positions": {
      +                  "description": "Candidate 1-indexed U positions that resolve the spatial conflict.",
      +                  "items": {
      +                    "exclusiveMinimum": 0,
      +                    "maximum": 9007199254740991,
      +                    "type": "integer"
      +                  },
      +                  "type": "array"
      +                },
      +                "target_cable_id": {
      +                  "description": "Cable connection cable_id targeted by this remediation action.",
      +                  "type": "string"
      +                },
      +                "target_instance_id": {
      +                  "description": "Device instance_id targeted by this remediation action.",
      +                  "type": "string"
      +                }
      +              },
      +              "required": [
      +                "action_type",
      +                "description"
      +              ],
      +              "type": "object"
      +            },
      +            "type": "array"
      +          },
      +          "remediation_suggestions": {
      +            "description": "Actionable self-correction instructions for the calling LLM agent.",
      +            "items": {
      +              "type": "string"
      +            },
      +            "minItems": 1,
      +            "type": "array"
      +          },
      +          "severity": {
      +            "description": "Severity level of the engineering constraint diagnostic.",
      +            "enum": [
      +              "ERROR",
      +              "WARNING",
      +              "INFO"
      +            ],
      +            "type": "string"
      +          },
      +          "stage": {
      +            "description": "Validation pipeline stage (1..5) that produced this finding.",
      +            "maximum": 5,
      +            "minimum": 1,
      +            "type": "integer"
      +          },
      +          "u_range": {
      +            "additionalItems": false,
      +            "description": "Inclusive [start_u, end_u] range where the issue occurs.",
      +            "items": [
      +              {
      +                "maximum": 9007199254740991,
      +                "minimum": -9007199254740991,
      +                "type": "integer"
      +              },
      +              {
      +                "maximum": 9007199254740991,
      +                "minimum": -9007199254740991,
      +                "type": "integer"
      +              }
      +            ],
      +            "maxItems": 2,
      +            "minItems": 2,
      +            "type": "array"
      +          }
      +        },
      +        "required": [
      +          "code",
      +          "severity",
      +          "affected_instances",
      +          "message",
      +          "remediation_suggestions"
      +        ],
      +        "type": "object"
      +      },
      +      "type": "array"
      +    },
      +    "status": {
      +      "description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[].",
      +      "enum": [
      +        "VALID",
      +        "INVALID"
      +      ],
      +      "type": "string"
      +    },
      +    "summary": {
      +      "description": "Concise human- and agent-readable summary of the tool result and validation status.",
      +      "type": "string"
      +    }
      +  },
      +  "required": [
      +    "status",
      +    "summary",
      +    "data",
      +    "issues"
      +  ],
      +  "type": "object"
      +}
  4. Addedv0.4.9

TDQS

A4.8/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare destructiveHint=true and readOnlyHint=false, and the description goes further by specifying exactly what is destroyed ('prior external drops on patch_panel_instance_id and their front patch cables before allocation') and by describing the error contract ('unmounted patch-panel or switch IDs return status INVALID without mutating state'). It also discloses allocation ordering (groups first, then endpoints, sequential free ports), which the annotations cannot convey.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Content is front-loaded with the core action, then batch semantics, then destruction, then routing guidance. It is efficient but the middle sentence chains many quoted parameter names into one long clause, making it denser than necessary to scan.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For an 8-parameter mutation tool with destructive behavior, the description covers the action, batch ordering, override precedence, port allocation, destructive side effects, and the failure mode. An output schema exists, so return-value detail is not required, and annotations already cover the safety profile.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the baseline is 3; the description earns above that by explaining cross-parameter dynamics the schema cannot express: groups are processed before endpoints, custom_labels[] overrides numbered label_prefix entries per index, and ports are allocated sequentially from start_port_number and auto_connect_switch_start_port. It does not explain entry_position's physical effect beyond the enum values, which keeps it from a 5.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource: 'Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel'. It also names what it is not (mount_equipment, connect_cables) and adds the distinguishing constraint of 'without consuming rack U slots', so an agent can separate it from siblings without reading schemas.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines5/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Explicit routing guidance is given in both directions: 'Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.' The destructive precondition (clear_existing) is also called out with a warning, leaving nothing to inference.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.