E4433B MCP Server
Click on "Deploy Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@E4433B MCP Server Set RF output to 1 GHz at -10 dBm"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
E4433B MCP server
Control an HP/Agilent E4433B ESG signal generator from an MCP client through an AR488 USB–GPIB adapter. Includes RF settings, analog AM, arbitrary waveform playback, verified WAV upload, expert SCPI query/write tools, and searchable original documentation converted to Markdown locally. No VISA runtime is needed.
Bench-tested with an E4433B identifying as ESG-D4000B, firmware B.03.86, options
1E5/UN8/UN9/UND, and AR488 0.55.22. Supports macOS and POSIX Linux; the process
lock currently uses fcntl, so native Windows is not supported.
Install
Install uv, then:
git clone https://github.com/ikatkov/e4433b-mcp.git
cd e4433b-mcp
./setupsetup installs Python into .python/ and dependencies into .venv/, both inside
this checkout. It copies dependencies instead of linking to another project's
files. The stable MCP entry point is run-mcp; clients need not know the
virtual environment path. Nothing opens the instrument during startup/discovery.
After relocating the checkout, rerun setup to regenerate environment paths.
The server has no network listener. Once installed, hardware control and manual search work offline. Hardware serial access and operating-system libraries remain normal external system interfaces.
Related MCP server: Instrument MCP Server
Connect a client
From the project directory, register the absolute launcher path.
Claude Code:
claude mcp add --scope user --transport stdio e4433b --env E4433B_ADDRESS=30 -- "$(pwd)/run-mcp"Codex:
codex mcp add e4433b --env E4433B_ADDRESS=30 -- "$(pwd)/run-mcp"Configure the client's tool-call timeout to 900 seconds for waveform transfers.
For Codex this is tool_timeout_sec = 900 in [mcp_servers.e4433b].
See the official Codex MCP documentation.
Reload the MCP connection or start a new client session after changing registration.
Any stdio MCP client can use this configuration, with its own timeout setting:
{
"mcpServers": {
"e4433b": {
"command": "/absolute/path/to/e4433b-mcp/run-mcp",
"env": {"E4433B_ADDRESS": "30"}
}
}
}Environment variable | Default | Purpose |
| automatic | Select the only CH340 adapter; set explicitly for other adapters or ambiguity. |
|
| Generator GPIB primary address. |
| unset | Optional check against your generator's serial number. |
The adapter link is 115200 baud. Start with get_status. Only one client may own
an adapter at a time; call disconnect before using it from another session.
Original documentation as Markdown
The catalog covers four original Agilent manuals, 1,205 source pages: base SCPI, front-panel operation, UND Dual ARB and UN8 real-time I/Q.
To build the local Markdown library, install curl and Poppler (pdftotext and
pdfinfo), then run:
uv run python scripts/fetch_manuals.pySource PDFs are temporary inputs and are removed after conversion. No PDFs are
stored in the project. The full manufacturer text retains its original copyright
and is not redistributed on GitHub or in package builds; see
third-party notices. Your generated .md files remain
inside src/e4433b_mcp/manuals/, usable with ordinary grep/rg and MCP search.
The server works without the manual download; the catalog reports availability and text tools explain how to install missing manuals. Once imported, no network is needed. Sources, editions, page numbering and conversion limitations are in the manual index.
Tools
Tool | Purpose |
| Enumerate USB adapters without connecting. |
| Read identity, options and the full signal-path configuration. |
| Return and consume the error queue without silently clearing it. |
| Set carrier/level; preserve modulation and RF state. |
| Explicit RF output enable/disable. |
| List volatile ARB waveforms. |
| Restore continuous I/Q playback of an existing waveform. |
| Configure ordinary analog sine AM. |
| Change active analog AM depth. |
| Convert mono 16-bit PCM WAV, upload separate I/Q planes and verify bytes. |
| Read I/Q hashes and sample ranges. |
| Release the adapter and optionally return front-panel control. |
| List manual editions, sources, coverage and local availability. |
| Search Markdown and return page references. |
| Read 1–5 source pages as Markdown. |
| Send one expert ASCII query and read exactly one response. |
| Send one expert ASCII non-query without extra commands. |
Static resources: e4433b://guide, e4433b://commands, e4433b://manuals.
Templates expose complete manuals and individual pages. Prefer typed controls for
supported tasks; use expert SCPI after checking model and option applicability.
ASCII commands must be shorter than 128 bytes and cannot contain batches/newlines.
Binary transfers use the dedicated block transport.
RF and transfer behavior
Configuration/playback tools leave RF off unless
rf_on=trueis explicit.set_rfpreserves the existing RF state.disconnectdoes not change RF state.Expert tools execute exactly the requested command. They add no RF mute, reset, error drain or retry. Verify writes using the documented query and
read_errors.One persistent serial connection avoids resetting the Nano per query. Whole operations are serialized; a process lease prevents competing clients.
++auto 0plus explicit query/read pairs avoids extra reads. On the verified firmware, options are read withDIAG:INFO:OPT?, not*OPT?.E443xB UND uploads use separate ARBI/ARBQ planes, offset-14-bit big-endian samples, escaped 96-byte chunks and final-only EOI. This differs from newer interleaved waveform formats. Interrupted uploads can leave partial files.
Typed configuration failures attempt RF off. A lost connection cannot guarantee physical output state. Writes are never automatically retried.
Uploaded voice AM depth is encoded in its I/Q samples; the analog AM depth menu does not change it. Instrument readback is distinct from a scope measurement.
See operating notes, command provenance, bench validation, and source-level comparisons.
Development
./setup
uv run pytest
uv run ruff check .
uv run python scripts/check_mcp.pyTests run without hardware or original manual downloads. An additional integration
test checks full manuals when installed. For a read-only live check, release any
other client and use uv run python scripts/check_mcp.py --hardware; it reads
status/catalog and disconnects without enabling RF or clearing errors.
MIT licensed code. Manufacturer documentation is separately owned.
Available Tools
17 toolsconfigure_am_toneAIdempotent
Configure ordinary sine-tone AM with adjustable front-panel depth.
Uses analog AM path 1 and disables ARB/IQ and competing modulation. Rate 0.1–50000 Hz, depth 0.1–100%. RF stays OFF unless rf_on=True. This replaces voice playback with a tone; it does not alter the stored voice waveform.
Inputs: level_dbm (required), frequency_hz (required), rf_on, rate_hz, +1 more.
disconnectAIdempotent
Release the adapter so another client can use it; preserve RF settings.
By default also return front-panel control. The next status/control call reconnects automatically. Server exit closes the port without turning RF off.
Inputs: return_local.
get_statusARead-only
Connect lazily and read E4433B identity, installed options, and live settings.
full=True also checks I/Q source, both analog modulation paths, ALC, high-crest mode, clocks, trigger, offsets, and blanking. Does not reset, clear errors, or change generator settings. Returns diagnostic notes.
Inputs: full.
inspect_waveformARead-only
Read stored I/Q samples and report hashes/ranges without modifying them.
This can take minutes and may interrupt playback while the instrument services the read. Marker/sequencer bits can change raw hashes without changing the lower 14-bit audio samples. This does not measure RF output.
Inputs: name (required).
list_adaptersARead-only
List USB serial adapters without opening ports or changing the instrument.
Inputs: no named parameters.
list_manualsARead-only
List local original-manual Markdown conversions, sources, coverage and page counts.
Inputs: no named parameters.
list_waveformsARead-only
List existing volatile ARB waveforms. Requires installed UND option.
Volatile waveforms can disappear after power-off. Check this before restoring playback; never assume yesterday's voice waveform still exists.
Inputs: no named parameters.
play_waveformAIdempotent
Restore a complete continuous I/Q playback setup using an existing waveform.
For our voice: name='VOICE_T12', sample_rate_hz=16000, frequency_hz=750000, level_dbm=-10. Specify rf_on=True only when output is requested. Restores internal I/Q and clock, master modulation, continuous trigger, normal crest mode, no gating/blanking or competing analog modulation, ALC off, and runs fixed-reference power search. Does not upload or modify samples. Voice modulation depth is encoded in the waveform, not the AM menu.
Inputs: name (required), level_dbm (required), frequency_hz (required), sample_rate_hz (required), +1 more.
read_errorsAIdempotent
Read and consume the instrument's error queue, returning every recorded error.
This is separate from status because reading removes the errors. No *CLS or preset is sent. Old errors are also returned by configuration tools.
Inputs: no named parameters.
read_manual_pagesARead-only
Read 1–5 source pages of original documentation as Markdown.
Page numbers are 1-based source-document pages, not printed chapter labels. Text preserves syntax and tables; diagrams are not reproduced. Check model, installed option and firmware applicability before issuing an exotic command.
Inputs: page (required), manual_id (required), page_count.
scpi_queryADestructive
Expert escape hatch: send ONE ASCII query and read ONE ASCII response.
Look up the command in the Markdown manuals first. Queries can consume state or start tests, so this is not universally read-only. No extra error query, preset, retry or RF change is added. For binary responses use the driver's block transport, not this ASCII tool. One printable command under 128 bytes; no semicolon batches, newlines or AR488 ++ commands. Unsupported queries may time out or cause -420. Query errors separately with read_errors.
Inputs: command (required).
scpi_writeADestructive
Expert escape hatch: send ONE ASCII non-query exactly as requested.
May change RF, erase data, reset or calibrate depending on the command; use only within the user's requested work after checking the manual. No automatic RF mute, preset, error drain or retry is added. Success confirms transport completion only: follow with the documented query and read_errors. Under 128 printable ASCII bytes; no semicolon batches, newlines, AR488 ++ commands or binary blocks. Prefer typed tools for supported procedures.
Inputs: command (required).
search_manualsARead-only
Search original manual text offline; return page references and short excerpts.
Literal, case-insensitive matching; whitespace is normalized. Search full command spellings (e.g. HICRest) or keywords, not only abbreviated SCPI. Use next_offset for more matches, read_manual_pages for complete context.
Inputs: query (required), offset, manual_id, max_results.
set_am_depthAIdempotent
Change active analog AM path 1 depth (0.1–100%). Preserves RF on/off.
Rejects I/Q voice playback: its depth must be changed by generating a new waveform with upload_am_wav. Does not silently switch modulation modes.
Inputs: depth_percent (required).
set_rfAIdempotent
Set a fixed carrier (250 kHz–4 GHz) and level setting (−135 to +20 dBm).
Preserves RF on/off and modulation. Clears frequency/power display offsets and reference modes, disables sweeps, and enables automatic attenuation. RF is temporarily muted while settings change. With scaled I/Q, level_dbm is a generator setting, not a calibrated carrier-power measurement.
Inputs: level_dbm (required), frequency_hz (required).
set_rf_outputAIdempotent
Explicitly turn RF OUTPUT on or off and verify the enable state.
Enabling uses the current frequency, level, and modulation. Read status first when these are unknown. Disabling does not discard the waveform.
Inputs: enabled (required).
upload_am_wavADestructive
Upload a local mono 16-bit PCM WAV as conventional AM using separate I/Q files.
Depth is a fraction (0.5 means 50% peak), range 0.001–0.99. Input must be 8–48 kHz, 16–131072 samples. Files stay local; no cloud service is involved. Uses E443xB offset-14-bit big-endian format and verifies every uploaded byte. Turns RF and ARB OFF and leaves them off. Call play_waveform separately. Existing names require overwrite=True. May take several minutes; configure the MCP client's tool timeout to 900 seconds. Partial files may remain on failure; no automatic upload retry or deletion is performed.
Inputs: name (required), path (required), depth, overwrite.
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
TDQS
Scored across 17 tools
Most tools have clearly distinct purposes, but set_rf and set_rf_output share similar names and both affect RF, creating potential misselection. The modulation-related tools (configure_am_tone, set_am_depth, upload_am_wav, play_waveform) are well differentiated by their detailed descriptions.
15 of 17 tools follow a consistent verb_noun pattern (e.g., list_manuals, set_rf, play_waveform), but scpi_query and scpi_write invert to noun_verb, and disconnect is verb-only. These are minor deviations from an otherwise predictable schema.
17 tools is borderline heavy for this server's apparent scope; the manual search (3 tools) and waveform/AM tools (6 tools) add up, though each has a distinct purpose. The count feels slightly over what is ideal.
The typed surface lacks a generic I/Q waveform upload or delete tool, and FM/PM/sweep modulation types are absent, relying on SCPI escape hatches. SCPI cannot perform binary uploads, so creating new voice waveforms is impossible through this server.
Maintenance
Related MCP Connectors
Create RF signal projects from prompts, inspect graphs, and export IQ data.
Write tunes for your Tesla coil, browse the teslacoil.app community and check leaderboards.
Turn STEP, DXF and SVG files into CNC milling and laser G-code for GRBL, LinuxCNC, Mach3 and more.
AILANG language reference, stdlib, examples and benchmarks for agents that write AILANG.
Related MCP Servers
- AlicenseAqualityCmaintenanceEnables control of MHS-5200A series signal generators via serial connection, including frequency, amplitude, waveform, and sweep settings.1616 PyPIMIT
- AlicenseCqualityBmaintenanceEnables natural language control of test instruments like spectrum analyzers and power supplies via SCPI commands, with auto-discovery and multi-instrument session support.1001MIT
- AlicenseNot gradedqualityDmaintenanceEnables control of Digilent WaveForms instruments (oscilloscope, AWG, logic analyzer) over USB, supporting devices like Analog Discovery 2/3 and Digital Discovery.3MIT
- FlicenseNot gradedqualityDmaintenanceEnables remote control of Siglent SDG series function/arbitrary waveform generators via SCPI over TCP/IP. Provides tools for configuring waveforms, modulation, sweep, burst, and other instrument functions.1-