An MCP server that lets Claude (Opus 5.5) work inside Proteus 8.6: draw schematics around ICs such as the 8086, attach firmware, run the simulation and check the result.

The acceptance target is the YTU BLM3061 (Mikroişlemci Sistemleri ve Assembly Dili) lab set: given a lab's tanım.pdf and its taslak.pdsprj, Claude should be able to produce a working .pdsprj and show that it meets the "İstenenler" list.

Status: usable. Every 2025 Proteus lab and odev2 has been completed through these tools by a fresh Claude session (below). TODO.md records the work and what still needs the owner, docs/FORMAT.md the file format notes, docs/QUIRKS.md the Proteus and MASM quirks the tools work around.

Status

Working and tested through a real MCP client (scripts/smoke_mcp.py), on this machine:

  • open a lab project into a workspace copy, read and replace its 8086 source;

  • build the firmware with MASM 5.10 (headless DOSBox, about 1 s) and store it in the project;

  • launch Proteus, run, pause and stop the simulation, read the simulation log, take screenshots of the window, of instrument popups and of Debug popups (registers, memory, 8255 status);

  • get Proteus's own netlist and ask which pins are on a net;

  • edit schematics without the GUI: list parts and pins, wire two pins together, attach GND / power / named-net terminals, change properties and values. Edits are written straight into the project file and were confirmed in Proteus 8.6 (opened without new warnings, connections present in Proteus's netlist);

  • place new device types from the libraries, delete and move parts, change annotated parts (8086 clock, program file, values) through Proteus's own dialog, and render the sheet as an image to check the layout.

Proteus was reinstalled on 2026-11-15; simulation of the 8086 labs now works (the earlier install could not drive 8086 I/O, see docs/QUIRKS.md).

Fresh-session test (the real acceptance check): a new Claude Opus 5.5 session, run headless with only these tools and the Read tool and given just the lab's PDF path, completed lab5 (all 8 keys show their digit), lab6 (8251 with a full 0158H decoder; DEF / NO / DEF on terminal 2), odev2 (ROM/RAM map; RAM shows the PDF's bytes) and lab8 (interrupt-driven ADC samples printed in hex, changing with the pot) on its own, including exporting the project and reporting how each requirement was checked. With only "do the lab in this PDF" as the prompt, a session also finished lab7 (LDR-controlled motor speed) with no tool errors. Prompts: e2e/prompt_*.txt. The tool problems those sessions reported are fixed. Run one yourself:

cd e2e
claude -p (Get-Content prompt_lab5.txt -Raw) --model claude-opus-5-5 --mcp-config mcp.json --strict-mcp-config `
  --allowedTools "mcp__proteus__*" "Read" --disallowedTools advisor

Worked example: scripts/lab5_example.py completes the 2025 lab5 template (8255 + 7-segment) entirely through the MCP tools: address wiring, eight added series resistors, port A to the display, port B to the buttons with pull-ups, a MASM 5.10 program, then 21 connectivity checks against Proteus's own netlist, all passing, and the 8086 loading the new program. It then runs the simulation and presses the eight buttons; the display shows 0 to 7 (docs/evidence/lab5_buttons.png).

scripts/lab6_example.py does lab6 (8251 USART): a full address decoder for 0158H/015AH built from the 74154, two 74HC4078 and four NOT gates, the 8251 and terminal wiring, and the program. Typing the PDF's three scenarios into terminal 1 prints DEFNODEF on terminal 2 (docs/evidence/lab6_terminals.png).

scripts/lab7_example.py does lab7 part 1 (DAC0830 at 200H, 100 Hz 32-sample sine): renames the YA1..YA6 placeholders, grounds the ADC pins the template leaves open, writes the program. Netlist checks pass and the simulation runs cleanly. The DAC was checked with the template's voltmeter and a slowed copy of the program: it follows the sine between 0 and 12 V (docs/evidence/lab7_dac_slow.png); the 100 Hz rate comes from the cycle count. That was before the scope could be used (see Limitations); today the scope shows it directly.

scripts/lab8_example.py does lab8 (8259 + ADC0804 + 8251) starting from the bare template: replaces the static POT with an interactive POT-HG, builds the 74154 decoder, wires 8259, 8251, ADC, terminal and two 9600 Hz clock generators, and writes an interrupt-driven program (vectors 51H/52H, edge triggered). The terminal, switched to Hex Display Mode by the tool, shows the samples; turning the pot changes them (e.g. 80 -> 66 -> 99, docs/evidence/lab8_pot_terminal.png).

scripts/odev2_example.py does odev2 (64 KB ROM at 20000H, 64 KB RAM at 60000H): two 74LS138 bank decoders (even on A0, odd on /BHE), an OR gate placed from the library plus three copies and a NOT for the A15 split, all ROM/RAM address, data and control lines, the ROM images copied with the project, and a program calling the two FAR routines. Paused, RAM00 shows 34 / CD and RAM01 12 / AB (docs/evidence/odev2_ram.png).

scripts/scratch_example.py builds a circuit that is in no template. It starts from lab6, deletes its 8251 (an annotated part, so Proteus itself deletes it and the leftover terminals are tidied), places an 8255A and a LED-RED from the libraries, copies the LED seven times, decodes the 8255 at 20H..26H with the 74154 and writes 0A5H to port A. LEDs PA0, PA2, PA5 and PA7 light (docs/evidence/scratch_8255_leds.png).

Wires are routed by a grid maze router (route.py): it never passes through a part body, pin, wire end, junction or terminal, never runs along an existing wire, and only crosses wires at right angles. Junction taps, wire deletion and moving wired parts were checked in Proteus with scripts/smoke_junction.py (its own netlist shows the intended nets; the file opens without a dialog).

Related MCP server: Altium MCP Server

Limitations

Verified on this machine (Proteus 8.6 SP2, build 23525) unless marked otherwise.

  • Scope: the Digital Oscilloscope works through the tools (2026-11-17): a 1 kHz generator on channel A of the 2025 lab7 solution draws its square wave and screenshot(window="Oscilloscope") captures it (docs/evidence/scope_1khz.png). The scope's settings are part properties (CHAACDC, CHAVAL, HORIZVAL ...) set with schematic_set_property while Proteus is closed; a saved design may have its channels switched off.

  • Bus wires are not drawn between pins. Buses are joined by named terminals (AD0 joins the AD[0..7] line) and wire labels, which is how the templates do it.

  • Annotated parts (U1, R3, ...) keep their properties in ROOT.CDB, which only Proteus may write: offline edits are refused, and proteus_edit_component(save=True) changes them through Proteus instead.

  • New device types are placed through the Pick Devices dialog with the real mouse; button presses, the pot and terminal hex mode use it too. The user should not move the mouse while these run.

  • Firmware: 8086 programs only (MASM 5.10 in DOSBox). PIC/AVR HEX firmware is not handled (unverified, no lab needs it).

  • Generators are left out of Proteus's netlist (Proteus's behaviour); net_of adds them from the sheet.

  • Only Proteus 8.6 project files (FILEVER 814) have been decoded. Other versions are untested; there is no explicit version check, so an edit on such a file may fail with a parse error.

  • The plain assembly labs (1 to 4, odev1) are out of scope: they have no Proteus project.

Install

Requirements: Windows, Proteus 8.6 SP2, DOSBox 0.74-3 (for the assembler), and uv, and MASM 5.10 (MASM.EXE and LINK.EXE, from the course materials). MASM is Microsoft software and is not shipped with proteus-mcp; see Finding MASM.

uvx runs the server straight from GitHub; no venv to manage. Check the setup first:

uvx --from git+https://github.com/Xedygen/proteus-mcp proteus-mcp doctor

Every line should say True except labs_found (see below). From a local checkout use --from D:\path\to\proteus-mcp instead; after changing the code, add --reinstall once so uvx rebuilds its cached copy.

Finding MASM

The server looks for a folder holding both MASM.EXE and LINK.EXE, in this order:

  1. the PROTEUS_MCP_MASM environment variable;

  2. the location saved in %LOCALAPPDATA%\proteus-mcp\config.json;

  3. tools\masm\ in a source checkout (ignored by git);

  4. a search of C:\masm, C:\MASM510 and similar, then three folder levels below your home folder (Desktop, Downloads, Documents, OneDrive) and each drive root. This takes well under a second, and the folder it finds is saved, so the search runs once.

If none of these finds it, firmware_build says so and Claude asks you where the folder is, then saves it with the masm_location tool. You can also tell Claude the folder at any time, or set PROTEUS_MCP_MASM.

Where things live when installed:

What

Default

Override

Proteus

C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional

PROTEUS_DIR

DOSBox

C:\Program Files (x86)\DOSBox-0.74-3\DOSBox.exe

DOSBOX_EXE

MASM 5.10

found as above

PROTEUS_MCP_MASM

Workspace (project copies)

%LOCALAPPDATA%\proteus-mcp\work

PROTEUS_MCP_WORK

Lab folders for lab_list

%LOCALAPPDATA%\proteus-mcp\labs

PROTEUS_MCP_LABS

Run from a source checkout (python -m proteus_mcp), the workspace and labs are work\ and labs\ in the repo instead. lab_list is a convenience; project_open takes any .pdsprj path.

Proteus runs visibly on the desktop. sim_click, terminal_mode and schematic_place_devices move the real mouse, so leave it alone while they run. (PROTEUS_MCP_BACKGROUND=1 hides Proteus off-screen; it was a development aid, and the oscilloscope does not draw there.)

Connect a client

Claude Code (add --scope user to have it in every project):

claude mcp add proteus -- uvx --from git+https://github.com/Xedygen/proteus-mcp proteus-mcp

Claude Desktop, in %APPDATA%\Claude\claude_desktop_config.json, then restart Claude Desktop:

{
  "mcpServers": {
    "proteus": {
      "command": "uvx",
      "args": ["--from", "git+https://github.com/Xedygen/proteus-mcp", "proteus-mcp"]
    }
  }
}

If Claude Desktop cannot find uvx, use its full path (where uvx, usually C:\Users\<you>\.local\bin\uvx.exe). The first start downloads the dependencies and takes a few seconds.

Tools

Tool

What it does

proteus_doctor

Install, versions, DOSBox and MASM, running Proteus processes

masm_location

Where MASM 5.10 is; with a path, checks and remembers it

quirks

Rules for code that builds and simulates here (MASM 5.10 limits, model quirks)

project_open, project_info, project_export

Workspace copies, one folder per project under work/projects/<name>/ (with the ROM images etc. it refers to); originals are never touched

firmware_get_source, firmware_build

Read main.asm; assemble and link (optionally with new source), store EXE in the project; errors with line numbers

proteus_launch, proteus_close

One Proteus instance at a time, only one this server started

sim_start, sim_pause, sim_stop, sim_status, sim_log

sim_start also checks that the 8086 loaded the EXE stored in the project

screenshot, debug_window

Main window or a named window; Debug-menu popups while paused (memory popups scrolled to an address)

sheet_image

The whole sheet rendered by Proteus's Export Bitmap at 100 to 600 DPI (sharp at any zoom), optionally cropped and saved

debug_memory

A memory popup (8086 Memory Dump, a RAM/ROM part's Memory Contents) as hex rows from any address, through the popup's own Copy All (checked on odev2: RAM00 34/CD)

sim_click, screenshot_part

Press a button / toggle a switch during a run (real mouse, guarded); close-up of one part

terminal_type, terminal_screenshot

Type into Virtual Terminals during a run; capture what they show

library_search

Offline search of the installed device libraries (about 55,000 devices: name, library, category, description), e.g. "4-to-16 decoder"

schematic_place_devices

Place new device types from the Proteus libraries (GUI, then saved by Proteus); unknown names, spots outside the sheet border or on an existing part or wire are refused before Proteus starts

proteus_background

Development aid, off by default: hides Proteus off-screen (mouse-based tools then refuse)

netlist, net_of

Proteus's own connectivity (Netlist Compiler, logical mode)

schematic_components

Parts, values, properties, pins with grid positions and connection state (unannotated parts as RES#0010, the netlist's names)

schematic_connect

Orthogonal wire between two unconnected pins, e.g. U2.Q1 to U3.A0; if one of them is already wired it taps that net instead

schematic_tap

Wire a free pin onto an existing net (a wired pin, terminal or wire label) with a junction dot

schematic_delete_wire

Delete the wire on a pin or at a point; a junction left with two wires is merged away

schematic_add_part

Place a copy of a part already in the design (e.g. a resistor or a 74HC373) with its own reference, optionally rotated or mirrored

schematic_add_terminal, schematic_add_terminals

GND, power or named-net terminal on a pin (AD0 joins the AD bus line). Supply names (+12V, -5V, VEE, V+) become a labelled power terminal, so Proteus drives that rail. The plural takes a list

schematic_add_wire_label

Name a net with a wire label; wires and terminals with the same name are one net (the label is placed clear of pins and of bodies estimated from pin positions; a body that extends past its pins, like the 7-segment display, can still be overlapped, so pass at_grid then)

schematic_rename_label

Rename terminals / wire labels (e.g. lab7's YA1..YA6)

schematic_set_property, schematic_set_value

Properties / value of unannotated parts, offline (annotated ones live in ROOT.CDB: use proteus_edit_component with save=True)

schematic_add_generator

Digital clock generator on a pin, e.g. 9600 Hz on the 8251's TxC/RxC

schematic_delete, schematic_move

Delete a part or generator with its wires (annotated parts such as an 8251 are deleted by Proteus itself, then the terminals, generators and junctions left at the far ends are tidied); move a part, dragging its wires along (re-routed where needed)

terminal_mode

Virtual Terminal options during a run, e.g. Hex Display Mode (real mouse)

lab_list

Lab folders with their PDF, template and reference solutions

schematic_labels

Offline list of net names (terminals, wire labels) and the pins wired to them

schematic_check

Offline: unconnected pins per part, terminals whose partner is missing or misspelled, parts outside the sheet border (they simulate but cannot be seen or clicked)

dialog_answer

Click a button in a Proteus dialog the server does not answer itself

proteus_edit_component

Change any part's properties or value (annotated too, e.g. the 8086 clock, VALUE of a resistor) through Proteus's own dialog, for the current session, or lasting with save=True (Proteus compiles once and saves)

Use it on a lab PDF

  1. Connect the server to Claude Code or Claude Desktop (above) and restart the client; /mcp in Claude Code or the tools icon in Desktop should list proteus.

  2. Leave Proteus closed; the server starts its own instance. Mouse-based steps (placing new device types, pressing buttons, the pot, terminal hex mode) move the real mouse; leave it alone while they run.

  3. Attach the lab's tanım.pdf to the chat (Desktop: drag it in; Claude Code: give its path) and ask, e.g.:

    "Use the proteus tools to do this lab. Find its template with lab_list, read quirks() first, wire what the PDF asks for, write and build the 8086 program, simulate it, show me evidence that every item of İstenenler works, and export the finished project to D:\Odev\lab8.pdsprj."

The finished project is a normal .pdsprj; open it in Proteus to look at or present it.

What is in this folder

Path

Contents

README.md

This file

LICENSE

MIT licence

TODO.md

Work order by milestone, and things needed from the owner

docs/FORMAT.md

What is known about the Proteus 8.6 project file format

docs/QUIRKS.md

Proteus, model and MASM 5.10 quirks (also served by the quirks tool)

docs/evidence/

Screenshots from the worked examples

src/proteus_mcp/

The server package

tests/

Tests that run without Proteus (.venv\Scripts\python.exe -m pytest -q)

scripts/

Worked lab examples, smoke tests, lab download and sample extraction

e2e/

Prompts and client config for the fresh-session acceptance runs

tools/masm/

Optional local MASM 5.10 copy for development (not in git)

labs/2024/, labs/2025/

Lab material pulled from the YTU archive repo (not in git)

labs/ is a copy of lablar/ from the archive. It holds the assignment PDFs, the instructor templates (taslak.pdsprj, proteus_sablon.pdsprj) and past student solutions. Re-create it with python -X utf8 scripts/pull_labs.py labs get.

The target labs

Proteus-based assignments (these are what the MCP must handle):

Lab

Topic

Parts

What "working" looks like

2025 lab5

8255 + 7-segment

8086, 74HC373, 8255A, common-anode 7-seg, 8 buttons, resistors

Pressing button N shows digit N

2025 lab6

8251 USART

8086, 3x 74273, 74154, 8251A, 2 virtual terminals, gates

Type A B C 0 in terminal 1, terminal 2 prints DEF; 8251 decoded at I/O 0158H

2025 lab7

DAC0830 / ADC0804

8086, latches, 74154, DAC0830, op-amp, scope (plus ADC, LDR, motors for part 2)

100 Hz, 32-step sine on the scope; or motor speed follows the LDR

2025 lab8

8259 + ADC0804 + 8251

8086, 3x 74273, 74154, 8251A, 8259, ADC0804, pot, virtual terminal

Five ADC samples printed as hex bytes, interrupt driven (vectors 51H, 52H)

2025 odev2

Memory map and address decoding

8086, 3x 74273, 2x 74LS138, 4x 27C128, 2x 62256

ROM at 20000H, RAM at 60000H, RAM00/RAM01 show the bytes written by the ROM routines

2024 lab 5 to 8

Same family of topics

Templates and solutions included

Extra test cases; lab 5 (8255 password, 7-segment) and lab 8 (DAC waveforms) done by fresh sessions

Labs 1 to 4 and odev1 (both years) ship only .asm / .cpp files and no Proteus project. They are plain assembly exercises with no circuit, so they are out of scope (decided in TODO.md); firmware_build still assembles them.

Two things stand out across all of them:

  1. Every Proteus lab starts from a template where the parts are already placed. The work is wiring, net labels, address decoding logic, part properties and the assembly program. Drawing from a blank sheet is rarely needed.

  2. The result is checked by looking: a 7-segment digit, virtual terminal text, a scope trace, a memory window. The MCP needs a way to read those back, not only to start the simulation.

What this machine has

Item

Finding

Proteus

8.6 SP2, build 8.6.23525, at C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional

8086 model

Present (MODELS\i8086.DLL), plus the VSM for 8086 demo board sample

Device libraries

162 .LIB files in LIBRARY\

8086 assembler

MASM 5.10 (MASM.EXE, LINK.EXE, debug.exe), handed out with the course materials for labs 2 and 3. These are 16-bit DOS programs, so they run through DOSBox

DOSBox

0.74-3 at C:\Program Files (x86)\DOSBox-0.74-3

Proteus's own Build button

Will not work: it expects MASM32 (ml.exe + link16.exe) in C:\masm32 or %PROGRAMFILES%\8086 Compilers Bundle, and neither exists. The MCP builds outside Proteus instead

Python / uv / Node

Python 3.10.11, uv, Node are installed

How a Proteus 8.6 project is stored

A .pdsprj is a ZIP archive. Lab 5's template contains:

Entry

Format

Role

PROJECT.XML

XML

Version stamp (RELEASE="806" FILEVER="814")

ROOT.DSN

Binary (ISIS SCHEMATIC FILE)

The drawing: parts, wires, labels, positions

ROOT.CDB

Binary with plain-text properties

Parts database: pins, nets, properties such as {PROGRAM=...}, {CLOCK=1MHz}, {LOAD_SEG=0x0000}

FIRMWARE.XML, FIRMWARE/8086.XML

XML

VSM Studio firmware project (compiler MASM32)

FIRMWARE/8086/main.asm

Text

The assembly source

FIRMWARE/8086/Debug/Debug.exe

DOS EXE

The built firmware the 8086 model loads

So the firmware half is easy to edit from outside Proteus (text and XML in a ZIP). The schematic half is a binary format with no public specification, and ROOT.DSN and ROOT.CDB must stay consistent with each other.

Proteus 8.6 has no official automation API.

Prior art

Repo

How it works

Why it was not used as is

chen0416ccc-cpu/Proteus-MCP

Writes .pdsprj files directly, live edits through Frida

Proteus 9 containers only (FILEVER 900 to 907), bridge pinned to build 9.0.40482, no 8086 firmware. Its DSN/CDB notes were the starting point for decoding 8.6 (credited in dsn.py)

jackmaikr4-sketch/keil-proteus-automation-skill-mcp

Drives the Proteus window through UI Automation

Cannot draw schematics; its menu-driven simulation control and Edit Component approach carried over (no code copied)

How it works

Python MCP server over stdio (official mcp SDK, managed with uv), Windows only. Three layers:

  1. Project files, offline. A .pdsprj is opened as a ZIP in a workspace copy; dsn.py parses and rebuilds ROOT.DSN byte for byte, schematic.py edits it (wires from a grid maze router, terminals, labels, part copies, generators) and netlist.py reads Proteus's own netlist. Templates are never written.

  2. Firmware. The 8086 source is assembled with the course's MASM 5.10 in headless DOSBox and the DOS EXE is stored where the project's firmware entry expects it.

  3. Proteus GUI. gui.py starts its own Proteus instance and drives it through menu commands and dialogs: simulation control, logs, Export Bitmap sheet images, Debug popups read as text, Edit Component, Pick Devices, button presses and terminal typing. Unknown dialogs are reported, never clicked through.

Results are checked against Proteus itself: its netlist for connectivity, its simulation log for the loaded program, and images or popup text for what the circuit does.

Licence

proteus-mcp is released under the MIT licence.

It does not include or redistribute any third-party software or course material:

  • Proteus is commercial software by Labcenter Electronics. You need your own licensed copy; proteus-mcp drives it the way a user would and does not modify or patch it.

  • MASM 5.10 and LINK are Microsoft software. They are not shipped; the server uses the copy you already have (see Finding MASM).

  • DOSBox is GPL software installed separately; proteus-mcp only starts it as an external program.

  • Lab material (labs/) is downloaded by scripts/pull_labs.py from a public archive repository for local testing and is not part of this repository.

  • Python dependencies (mcp, pywinauto, pywin32, Pillow) are installed from PyPI under their own permissive licences (MIT, BSD-3-Clause, PSF, MIT-CMU).

Proteus and Labcenter are trademarks of Labcenter Electronics Ltd; MASM is a trademark of Microsoft Corporation. This project is not affiliated with or endorsed by either.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers