Skip to main content
Glama
msox2014a-mcp
by SMEAC

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault
MSOX_RESOURCENoVISA resource to auto-connect on first tool call. Set to SIM to select the simulator.
MSOX_LOG_LEVELNoLog level. Logs go to stderr.WARNING
MSOX_VISA_LIBRARYNoVISA library to use: @ivi, @py, or a path to a VISA DLL. Defaults to vendor VISA, falling back to @py.
MSOX_MCP_CAPTURE_DIRNoDirectory where CSV, JSON, PNG, and setup files are written.~/msox2014a_captures

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

Controls an Agilent/Keysight MSO-X 2014A mixed-signal oscilloscope (4 analog channels, 8 digital channels, optional WaveGen) over USB/LAN via VISA. Start with scope_device(operation='connect') - resource='SIM' gives a built-in simulator. Typical flow: connect -> autoscale or configure -> scope_capture (single) -> scope_measure / preview / export. scope_help(operation='quickstart') explains more.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": true
}
logging
{}
prompts
{
  "listChanged": true
}
resources
{
  "subscribe": false,
  "listChanged": true
}

Tools

Functions exposed to the LLM to take actions

NameDescription
scope_deviceC

Discover, connect to and manage the MSO-X 2014A.

scope_configureC

Configure the analog channels, timebase, acquisition mode and digital (MSO) channels.

scope_triggerC

Configure and control the edge trigger.

scope_captureB

Acquire and download waveforms, export them, or grab a screenshot.

scope_measureC

Measure amplitude/timing parameters, phase, or the spectrum of a signal.

scope_wavegenC

Control the scope's built-in waveform generator (front-panel 'Gen Out' BNC).

scope_scpiA

Send a raw SCPI command (escape hatch for anything the other tools don't cover).

scope_helpC

Usage guidance for this server and the MSO-X 2014A.

Prompts

Interactive templates invoked by user choice

NameDescription
characterize_signalCharacterise an unknown signal on a channel
wavegen_loopbackMeasure a circuit's response using the built-in WaveGen

Resources

Contextual data attached and managed by the client

NameDescription
status_resourceConnection and run state
last_capture_resourceSummary of the last capture

TDQS

B3.4/5.0

Scored across 8 tools

Disambiguation4/5

Each tool maps to a distinct stage of scope work (connect, configure, trigger, capture, measure, wavegen), so an agent can generally pick correctly. The main soft spots are scope_measure vs scope_capture (both produce signal data) and scope_scpi, which can theoretically do anything the other tools do.

Naming Consistency5/5

All eight tools use a uniform scope_<noun/verb> snake_case pattern with no deviations. The prefix also correctly identifies the server's instrument domain.

Tool Count5/5

Eight tools is well within the sweet spot and each covers a coherent functional area: session, configuration, trigger, acquisition, measurement, wavegen, raw SCPI, help. No tool feels redundant or padded.

Completeness4/5

The core lifecycle — discover/connect, configure, trigger, capture, measure, generate — is fully covered, plus a raw SCPI escape hatch and help. Secondary areas like math/FFT setup, cursors, serial decode, or save/recall of instrument setups are absent, though SCPI can bridge them.

Maintenance

ActivityMaintained
ResponsivenessNo recent community issues