Skip to main content
Glama
MyLeadTech MCP

MyLeadTech MCP

Official

MyLeadTech MCP

HVAC MCP server — fault codes, model lookup and answers cited to the OEM manual page.

This repository holds the connection details and registry metadata for the hosted MyLeadTech MCP server (the server itself runs at the endpoint below), plus a small local stdio server (myleadtech_mcp/) that forwards the same tools to the MyLeadTech REST API with your key.

  • Endpoint: https://mcp.myleadtech.app/mcp/

  • Transport: Streamable HTTP

  • Auth: API key from the MyLeadTech dashboard, sent as Authorization: Bearer <api_key>. The site also lists OAuth sign-in with a MyLeadTech account for clients that support it.

  • Brands served: the top 50 US HVAC brands — full list: myleadtech.app/brands

  • Contract: ar-00/1 (every response carries contract_version and the MLT-Contract header). Adding a field is not a breaking change; a breaking change ships as a new contract version with 12 months notice.

  • Server card: https://mcp.myleadtech.app/.well-known/mcp/server-card.json (same 7 tools as tools/list).

  • Plans: Sandbox 100 free units a month; Builder 2,000 and Production 15,000 units a month per company (pricing). Equipment lookups, sources, pages, usage, clarifying questions and empty results don't count. A retried request with the same operation_id / idempotency key is never charged twice (keys kept 7 days).

  • Rate limits: 60 searches and fault-code lookups, 30 answers per minute (per server instance). A refused call returns rate_limited with retry_after_seconds and is not charged.

Tools

Tool

What it does

Parameters

resolve_equipment

Turns a model or nameplate reference into brand and equipment, and reports coverage. Not billed.

reference, market (default us), language (default en-US)

search_hvac_documents

Finds passages and citations (document, page) in manufacturer documents. 1 unit when status is ok.

question, brand, model_reference, fault_code, language, limit (default 5), max_chars, operation_id

get_hvac_source

Returns a cited passage with bounded context. Not billed.

source_id

answer_hvac_question

A written answer with page-level claims (page_number, document_title), next_action, a guarded one-sentence summary and a safety notice. 1 unit only when a claim rests on a source established for the equipment (see below).

question, brand, model_reference, fault_code, language, limit (default 5), audience, max_chars, operation_id

lookup_fault_code

The published meaning of a fault code, quoted verbatim with its page. No generation. A missing brand returns a clarification and an unpublished code returns empty; neither is billed. 1 unit when status is ok.

code, brand, model_reference, language, operation_id

get_hvac_document_page

Page or zone cited, as a PNG image. The PDF is not provided. Not billed.

document_version_id, page_number, format (png only), region

get_usage

Plan, monthly allowance, units used and remaining, and window_end. Not billed.

none

  • operation_id makes a retry replay the earlier result instead of charging again.

  • audience: technician (default) or homeowner; for a homeowner, answers that touch refrigerant, electrical or gas work set requires_qualified_technician.

  • max_chars: 80 to 1,200 characters per passage (default 480). Truncated passages say so (truncated, truncation_reason).

  • answer_hvac_question billing: an ok answer whose claims rest only on documentation not confirmed for your unit (for example a family-level manual) is not billed: usage.debited is false. Read usage.debited and usage.units, not status, to know what was charged.

  • Errors carry request_id, code, message and, when they apply, param, doc_url and retry_after_seconds (same body over REST and MCP). Codes: https://myleadtech.app/developers/docs#errors

Related MCP server: thermia-kb-mcp

Install

Create an API key in the dashboard first.

Claude Code

claude mcp add --transport http myleadtech https://mcp.myleadtech.app/mcp/ --header "Authorization: Bearer YOUR_API_KEY"

Without --header, Claude Code can sign you in with your MyLeadTech account instead.

Cursor

Paste into .cursor/mcp.json:

{
  "mcpServers": {
    "myleadtech": {
      "url": "https://mcp.myleadtech.app/mcp/",
      "headers": { "Authorization": "Bearer YOUR_API_KEY" }
    }
  }
}

VS Code

Paste into .vscode/mcp.json:

{
  "servers": {
    "myleadtech": {
      "type": "http",
      "url": "https://mcp.myleadtech.app/mcp/",
      "headers": { "Authorization": "Bearer YOUR_API_KEY" }
    }
  }
}

Run it locally (stdio)

The repository also ships a local stdio server. It calls the MyLeadTech REST API with your key; no manual or index is bundled in this repository.

Tools: the same seven as the hosted server. lookup_fault_code is on by default since 0.4.0; set MYLEADTECH_ENABLE_LOOKUP_FAULT_CODE=0 to leave it out.

pip install .
MYLEADTECH_API_KEY=<your key> myleadtech-mcp

Optional: MYLEADTECH_API_URL (default https://api.myleadtech.app). Requires Python 3.10+.

Retries: a 429 rate_limited, 503, 504 or network timeout is retried up to 3 times, always with the same idempotency key, so the request is charged once. quota_exceeded, not_entitled, conflict and other 4xx are never retried. Errors read <code>: <message> (request_id=...); quote the request_id to support.

Other clients

Any MCP client that supports remote Streamable HTTP servers: endpoint https://mcp.myleadtech.app/mcp/, header Authorization: Bearer <api_key>.

Example

Call answer_hvac_question with:

{ "question": "What refrigerant does the EXA-36 use?", "brand": "example_air", "model_reference": "EXA-36-B2" }

Response shape (illustrative, ar-00/1: invented ids and text, not a live call and not manufacturer content):

{
  "request_id": "00000000-0000-4000-8000-0000000000a1",
  "contract_version": "ar-00/1",
  "status": "ok",
  "partial": false,
  "missing": [],
  "degraded": [],
  "usage": {
    "operation": "answer",
    "debited": true,
    "units": 1,
    "remaining": 98
  },
  "next_action": "answer",
  "summary": "Illustrative summary: this example unit uses refrigerant R-000.",
  "summary_source_ids": ["chunk:00000000-0000-4000-8000-000000000001"],
  "answer": "Illustrative answer: this example unit uses refrigerant R-000.",
  "claims": [
    {
      "text": "Illustrative claim: the unit uses refrigerant R-000.",
      "source_id": "chunk:00000000-0000-4000-8000-000000000001",
      "page_number": 1,
      "document_title": "Illustrative product data"
    }
  ],
  "requires_qualified_technician": false,
  "notice": "Manufacturer documentation, not verified by MyLeadTech for your installation. Work on refrigerant, electrical or gas systems requires a qualified technician.",
  "limits": [],
  "passages": [
    {
      "source_id": "chunk:00000000-0000-4000-8000-000000000001",
      "document_version_id": "00000000-0000-4000-8000-000000000002",
      "document_type": "product_data",
      "text": "Illustrative passage text, invented for this README.",
      "pages": [1],
      "applicability": "established",
      "rank": 1,
      "citations": []
    }
  ]
}

Here debited is true because the claim rests on a passage whose applicability is established. With documentation not confirmed for the unit, the same ok answer comes back with debited: false and no unit charged. The cited page is available as a PNG image through get_hvac_document_page.

Listings

M8ven Score

License

MIT, for the files in this repository only (README and configuration). The MyLeadTech service and the manufacturer documents it cites are not covered.

Available Tools

5 tools
answer_hvac_questionAnswer HVAC questionA
Read-only
Inspect

Answer an HVAC service question with citations to the OEM manual page it came from. Returns empty rather than guessing when no source supports an answer.

Inputs: question (required), brand, limit, language, +3 more. Returns: object

get_hvac_document_pageGet manual pageC
Read-onlyIdempotent
Inspect

Return a source manual page as a PNG image (format png only; PDF output is disabled).

Inputs: page_number (required), document_version_id (required), region.

get_hvac_sourceGet cited sourceA
Read-onlyIdempotent
Inspect

Return the passage and bounded context of a source already cited by search or answer.

Inputs: source_id (required). Returns: object

resolve_equipmentResolve HVAC equipmentB
Read-onlyIdempotent
Inspect

Resolve an HVAC model or nameplate reference to brand, family and documentation coverage. Not billed.

Inputs: reference (required), market, language. Returns: object

search_hvac_documentsSearch HVAC documentsB
Read-only
Inspect

Search OEM HVAC manuals by question, brand, model reference or fault code. Returns bounded passages with citations (document, page).

Inputs: question (required), brand, limit, language, +3 more. Returns: object

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.5/5.0

    Scored across 5 tools

    Disambiguation4/5

    Each tool has a reasonably distinct role: resolve maps a model/nameplate to brand metadata, search returns candidate passages, answer synthesizes a cited answer, get_hvac_source expands an already-cited source, and get_hvac_document_page renders a page image. The main overlap is between search_hvac_documents and answer_hvac_question, both keyed on a question and returning cited HVAC content, though the descriptions clarify that one retrieves passages and the other produces a synthesized answer.

    Naming Consistency4/5

    All names use snake_case with a clear verb-first pattern (resolve_, get_, search_, answer_), which is predictable and readable. The only minor deviation is that resolve_equipment omits the hvac domain token used by the other names, but the convention is otherwise consistent.

    Tool Count5/5

    Five tools is well-scoped for an HVAC document retrieval and QA server. Each tool supports a distinct step in the workflow—resolve, search, answer, expand source, fetch page—without padding.

    Completeness4/5

    The surface covers the core retrieval lifecycle: identify equipment, search manuals, answer with citations, retrieve cited passages, and fetch page images. Minor gaps exist around browsing available brands/documents or listing coverage, but agents can work around those through search and resolve.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      Not graded
      quality
      C
      maintenance
      Provides AI agents with manufacturer-sourced HVAC technical documentation, enabling error-code lookup, diagnostics, and guided troubleshooting with exact source citations.
      MIT
    • A
      license
      A
      quality
      C
      maintenance
      Enables AI assistants to query a verified bilingual technical knowledge base for the Thermia Duo 12 heat pump and verify facts against original manuals via section search, terminal and register lookup, schematic access, and PDF page rendering or text extraction.
      10
      MIT
    • A
      license
      A
      quality
      C
      maintenance
      Enables AI agents to run deterministic data-center engineering calculations and commissioning audits, including liquid-cooling hydraulics, pipe friction and flow checks, corrosion severity classification, protocol search, and defect-code lookup.
      6
      2
      MIT
    • A
      license
      Not graded
      quality
      C
      maintenance
      Enables AI assistants to check real availability, retrieve service prices and cancellation terms, and book, reschedule, or cancel appointments with connected HVAC and plumbing businesses.
      MIT