MyLeadTech MCP
OfficialClick on "Deploy Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@MyLeadTech MCP What fault code E4 mean on a Trane XR15?"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
MyLeadTech MCP
HVAC MCP server — fault codes, model lookup and answers cited to the OEM manual page.
This repository holds the connection details and registry metadata for the hosted MyLeadTech MCP server (the server itself runs at the endpoint below), plus a small local stdio server (myleadtech_mcp/) that forwards the same tools to the MyLeadTech REST API with your key.
Endpoint:
https://mcp.myleadtech.app/mcp/Transport: Streamable HTTP
Auth: API key from the MyLeadTech dashboard, sent as
Authorization: Bearer <api_key>. The site also lists OAuth sign-in with a MyLeadTech account for clients that support it.Brands served: the top 50 US HVAC brands — full list: myleadtech.app/brands
Contract:
ar-00/1(every response carriescontract_versionand theMLT-Contractheader). Adding a field is not a breaking change; a breaking change ships as a new contract version with 12 months notice.Server card:
https://mcp.myleadtech.app/.well-known/mcp/server-card.json(same 7 tools astools/list).Plans: Sandbox 100 free units a month; Builder 2,000 and Production 15,000 units a month per company (pricing). Equipment lookups, sources, pages, usage, clarifying questions and empty results don't count. A retried request with the same
operation_id/ idempotency key is never charged twice (keys kept 7 days).Rate limits: 60 searches and fault-code lookups, 30 answers per minute (per server instance). A refused call returns
rate_limitedwithretry_after_secondsand is not charged.
Tools
Tool | What it does | Parameters |
| Turns a model or nameplate reference into brand and equipment, and reports coverage. Not billed. |
|
| Finds passages and citations (document, page) in manufacturer documents. 1 unit when status is |
|
| Returns a cited passage with bounded context. Not billed. |
|
| A written answer with page-level claims ( |
|
| The published meaning of a fault code, quoted verbatim with its page. No generation. A missing brand returns a clarification and an unpublished code returns empty; neither is billed. 1 unit when status is |
|
| Page or zone cited, as a PNG image. The PDF is not provided. Not billed. |
|
| Plan, monthly allowance, units used and remaining, and | none |
operation_idmakes a retry replay the earlier result instead of charging again.audience:technician(default) orhomeowner; for a homeowner, answers that touch refrigerant, electrical or gas work setrequires_qualified_technician.max_chars: 80 to 1,200 characters per passage (default 480). Truncated passages say so (truncated,truncation_reason).answer_hvac_questionbilling: anokanswer whose claims rest only on documentation not confirmed for your unit (for example a family-level manual) is not billed:usage.debitedisfalse. Readusage.debitedandusage.units, notstatus, to know what was charged.Errors carry
request_id,code,messageand, when they apply,param,doc_urlandretry_after_seconds(same body over REST and MCP). Codes: https://myleadtech.app/developers/docs#errors
Related MCP server: thermia-kb-mcp
Install
Create an API key in the dashboard first.
Claude Code
claude mcp add --transport http myleadtech https://mcp.myleadtech.app/mcp/ --header "Authorization: Bearer YOUR_API_KEY"Without --header, Claude Code can sign you in with your MyLeadTech account instead.
Cursor
Paste into .cursor/mcp.json:
{
"mcpServers": {
"myleadtech": {
"url": "https://mcp.myleadtech.app/mcp/",
"headers": { "Authorization": "Bearer YOUR_API_KEY" }
}
}
}VS Code
Paste into .vscode/mcp.json:
{
"servers": {
"myleadtech": {
"type": "http",
"url": "https://mcp.myleadtech.app/mcp/",
"headers": { "Authorization": "Bearer YOUR_API_KEY" }
}
}
}Run it locally (stdio)
The repository also ships a local stdio server. It calls the MyLeadTech REST API with your key; no manual or index is bundled in this repository.
Tools: the same seven as the hosted server. lookup_fault_code is on by default since 0.4.0; set MYLEADTECH_ENABLE_LOOKUP_FAULT_CODE=0 to leave it out.
pip install .
MYLEADTECH_API_KEY=<your key> myleadtech-mcpOptional: MYLEADTECH_API_URL (default https://api.myleadtech.app). Requires Python 3.10+.
Retries: a 429 rate_limited, 503, 504 or network timeout is retried up to 3 times, always with the same idempotency key, so the request is charged once. quota_exceeded, not_entitled, conflict and other 4xx are never retried. Errors read <code>: <message> (request_id=...); quote the request_id to support.
Other clients
Any MCP client that supports remote Streamable HTTP servers: endpoint https://mcp.myleadtech.app/mcp/, header Authorization: Bearer <api_key>.
Example
Call answer_hvac_question with:
{ "question": "What refrigerant does the EXA-36 use?", "brand": "example_air", "model_reference": "EXA-36-B2" }Response shape (illustrative, ar-00/1: invented ids and text, not a live call and not manufacturer content):
{
"request_id": "00000000-0000-4000-8000-0000000000a1",
"contract_version": "ar-00/1",
"status": "ok",
"partial": false,
"missing": [],
"degraded": [],
"usage": {
"operation": "answer",
"debited": true,
"units": 1,
"remaining": 98
},
"next_action": "answer",
"summary": "Illustrative summary: this example unit uses refrigerant R-000.",
"summary_source_ids": ["chunk:00000000-0000-4000-8000-000000000001"],
"answer": "Illustrative answer: this example unit uses refrigerant R-000.",
"claims": [
{
"text": "Illustrative claim: the unit uses refrigerant R-000.",
"source_id": "chunk:00000000-0000-4000-8000-000000000001",
"page_number": 1,
"document_title": "Illustrative product data"
}
],
"requires_qualified_technician": false,
"notice": "Manufacturer documentation, not verified by MyLeadTech for your installation. Work on refrigerant, electrical or gas systems requires a qualified technician.",
"limits": [],
"passages": [
{
"source_id": "chunk:00000000-0000-4000-8000-000000000001",
"document_version_id": "00000000-0000-4000-8000-000000000002",
"document_type": "product_data",
"text": "Illustrative passage text, invented for this README.",
"pages": [1],
"applicability": "established",
"rank": 1,
"citations": []
}
]
}Here debited is true because the claim rests on a passage whose applicability is established. With documentation not confirmed for the unit, the same ok answer comes back with debited: false and no unit charged. The cited page is available as a PNG image through get_hvac_document_page.
Links
Developer docs: https://myleadtech.app/developers/docs
MCP guide: https://myleadtech.app/developers/mcp
REST OpenAPI spec: https://api.myleadtech.app/v1/openapi.json
Site: https://myleadtech.app
Get an API key: https://web.myleadtech.app
Listings
License
MIT, for the files in this repository only (README and configuration). The MyLeadTech service and the manufacturer documents it cites are not covered.
Available Tools
5 toolsanswer_hvac_questionAnswer HVAC questionARead-onlyInspect
Answer an HVAC service question with citations to the OEM manual page it came from. Returns empty rather than guessing when no source supports an answer.
Inputs: question (required), brand, limit, language, +3 more. Returns: object
get_hvac_document_pageGet manual pageCRead-onlyIdempotentInspect
Return a source manual page as a PNG image (format png only; PDF output is disabled).
Inputs: page_number (required), document_version_id (required), region.
get_hvac_sourceGet cited sourceARead-onlyIdempotentInspect
Return the passage and bounded context of a source already cited by search or answer.
Inputs: source_id (required). Returns: object
resolve_equipmentResolve HVAC equipmentBRead-onlyIdempotentInspect
Resolve an HVAC model or nameplate reference to brand, family and documentation coverage. Not billed.
Inputs: reference (required), market, language. Returns: object
search_hvac_documentsSearch HVAC documentsBRead-onlyInspect
Search OEM HVAC manuals by question, brand, model reference or fault code. Returns bounded passages with citations (document, page).
Inputs: question (required), brand, limit, language, +3 more. Returns: object
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
TDQS
Scored across 5 tools
Each tool has a reasonably distinct role: resolve maps a model/nameplate to brand metadata, search returns candidate passages, answer synthesizes a cited answer, get_hvac_source expands an already-cited source, and get_hvac_document_page renders a page image. The main overlap is between search_hvac_documents and answer_hvac_question, both keyed on a question and returning cited HVAC content, though the descriptions clarify that one retrieves passages and the other produces a synthesized answer.
All names use snake_case with a clear verb-first pattern (resolve_, get_, search_, answer_), which is predictable and readable. The only minor deviation is that resolve_equipment omits the hvac domain token used by the other names, but the convention is otherwise consistent.
Five tools is well-scoped for an HVAC document retrieval and QA server. Each tool supports a distinct step in the workflow—resolve, search, answer, expand source, fetch page—without padding.
The surface covers the core retrieval lifecycle: identify equipment, search manuals, answer with citations, retrieve cited passages, and fetch page images. Minor gaps exist around browsing available brands/documents or listing coverage, but agents can work around those through search and resolve.
Maintenance
Related MCP Connectors
15 HVAC MCP tools: lookups, SKU provenance, guided PAC, Beta Harness sessions. 126 brands.
Heating, ventilation and energy engineering calculations and diagnostics for AI agents.
PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
Search and query nTop's knowledge base and engineering guides from AI applications.
Related MCP Servers
- AlicenseNot gradedqualityCmaintenanceProvides AI agents with manufacturer-sourced HVAC technical documentation, enabling error-code lookup, diagnostics, and guided troubleshooting with exact source citations.MIT
- AlicenseAqualityCmaintenanceEnables AI assistants to query a verified bilingual technical knowledge base for the Thermia Duo 12 heat pump and verify facts against original manuals via section search, terminal and register lookup, schematic access, and PDF page rendering or text extraction.10MIT
- AlicenseAqualityCmaintenanceEnables AI agents to run deterministic data-center engineering calculations and commissioning audits, including liquid-cooling hydraulics, pipe friction and flow checks, corrosion severity classification, protocol search, and defect-code lookup.62MIT
- AlicenseNot gradedqualityCmaintenanceEnables AI assistants to check real availability, retrieve service prices and cancellation terms, and book, reschedule, or cancel appointments with connected HVAC and plumbing businesses.MIT