    • A
      license
      Not graded
      quality
      D
      maintenance
      Enables control of the Multicomp Pro MP711134 bench power supply and multimeter over USB serial, allowing an LLM agent to power-cycle boards, measure current profiles during boot, run custom voltage/current profiles, and wait for conditions without polling.
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables AI assistants to automatically discover and control supported laboratory instruments over USB, LAN, and serial connections, including power-supply output, setpoint, and protection management plus multimeter measurements.
      2
      MIT
    • F
      license
      Not graded
      quality
      C
      maintenance
      Enables LLMs to control an RND 320-KA3005P lab power supply through MCP tools, allowing natural language commands to set voltage/current, toggle output, and read measurements.
      -
    • A
      license
      B
      quality
      C
      maintenance
      Enables agentic coding harnesses to control benchtop test equipment — waveform generator, multimeter, oscilloscope, and power supply — over SCPI, with typed tools and raw passthrough for investigating circuits.
      76
      1
      MIT
    • A
      license
      A
      quality
      D
      maintenance
      An MCP server that lets AI agents control an RS PRO RS-3005P/RS-6005P programmable DC power supply over USB/RS232, enabling voltage/current control, measurements, output switching, and memory operations.
      14
      MIT

    TDQS

    A3.6/5.0

    Scored across 12 tools

    Disambiguation4/5

    Most tools have clearly distinct purposes (set vs output vs status vs ports vs selftest). The main overlap is between status, watch, and log_start (all sample the same measurements, differing only in short-run vs background/file), and between set and param_list (different screen/register models). Descriptions provide enough detail to tell them apart, but the boundaries require careful reading.

    Naming Consistency3/5

    A partial verb_noun pattern exists (log_start, sequence_start, job_status, job_stop, param_list, display_colors), but several tools are bare nouns or ambiguous single words (set, output, status, ports, watch). The conventions are readable but not predictable—'set' and 'output' are especially terse given the domain.

    Tool Count5/5

    Twelve tools is well-scoped for a bench power supply: configuration, output control, discovery, measurement, logging, sequencing, job management, and diagnostics each earn their place. No tool feels redundant or trivial.

    Completeness4/5

    The lifecycle is well covered: discovery, status/measurement, setting, output switching, background logging and sequencing with job start/status/stop, plus selftest. Minor gaps remain—no way to read back a parameter list's stored values, no job enumeration/listing, and no log file management—but agents can work around these.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues