Skip to main content
Glama

BRAINIAC Solar PV Design Calculations

Server Details

Paid Solar PV Design Calculations API via x402. Unpaid tool calls return 402.

If you are the author of this connector, you can claim ownership. Claimed connector authors can inspect health checks, view analytics, and manage their listing.
Status
Healthy
Uptime
100.0% over the last 24 hours
Last Tested
Transport
Streamable HTTP · MCP 2025-11-25
URL
ChatGPT
–
Claude
–

TDQS

A4/5.0

Scored across 14 tools

Disambiguation4/5

Each tool targets a distinct calculation step in a PV design workflow (shading, transposition, string sizing, NEC current, battery sizing, finance), so misselection is unlikely for most pairs. Minor overlap exists between energy-yield-estimate, dc-ac-ratio-check and system-loss-stack (all touch AC energy and loss derating), and between financial-payback and tariff-savings, but descriptions clarify the boundaries.

Naming Consistency5/5

Every tool uses the identical `solar-design_` prefix followed by a kebab-case descriptive domain name, with no camelCase or style drift. The pattern is fully predictable even though it is noun-phrase rather than verb_noun style.

Tool Count5/5

14 tools sit in the well-scoped range and each maps to a discrete, non-trivial engineering calculation. Nothing feels padded or missing at the count level for a solar PV design calculation suite.

Completeness4/5

The surface covers the core PV design lifecycle: irradiance transposition, shading, layout, row spacing, string sizing, NEC 690 current, battery backup, loss stack, yield, and both financial and tariff analysis. Gaps remain for voltage drop / conductor sizing, weather-data ingestion, and report export, but these are workarounds an agent can handle or are out of scope.

Available Tools

14 tools
solar-design_battery-backup-sizingSize battery backup energy and inverter powerA
Read-onlyIdempotent
Inspect

Size battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates. Price $0.03 USDC. POST /api/v1/solar-design/battery-backup-sizing. An unpaid call returns the x402 payment terms and does not run.

Inputs: loads (required), autonomyHours (required), depthOfDischarge (required), dischargeEfficiency (required), +4 more. Returns: sources, limitations, energyNeededKwh, inverterSurgeKw, +2 more

solar-design_dc-ac-ratio-checkCheck DC/AC ratio and inverter clippingA
Read-onlyIdempotent
Inspect

Compute the DC/AC ratio and optionally estimate AC energy and clipping from a caller DC power series with constant efficiency or a PVWatts inverter curve. Price $0.03 USDC. POST /api/v1/solar-design/dc-ac-ratio-check. An unpaid call returns the x402 payment terms and does not run.

Inputs: acRatingKw (required), dcNameplateKw (required), useCecCurve, intervalHours, +3 more. Returns: sources, warnings, dcAcRatio, acEnergyKwh, +3 more

solar-design_energy-yield-estimateEstimate AC energy with PVWatts v5A
Read-onlyIdempotent
Inspect

Estimate AC energy from caller POA irradiance and temperatures using the PVWatts v5 DC and inverter models with a transparent loss stack. Price $0.04 USDC. POST /api/v1/solar-design/energy-yield-estimate. An unpaid call returns the x402 payment terms and does not run.

Inputs: gammaPdc (required), acRatingW (required), dcNameplateW (required), monthly, +5 more. Returns: records, sources, lossStack, totalAcKwh, +2 more

solar-design_financial-paybackCompute PV payback, NPV, IRR and LCOEA
Read-onlyIdempotent
Inspect

Compute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation. Price $0.03 USDC. POST /api/v1/solar-design/financial-payback. An unpaid call returns the x402 payment terms and does not run.

Inputs: capex (required), years (required), discountRate (required), year1EnergyKwh (required), +6 more. Returns: irr, npv, lcoe, sources, +4 more

solar-design_horizon-shading-lossEstimate far-field horizon shading lossesA
Read-onlyIdempotent
Inspect

Estimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA. Price $0.03 USDC. POST /api/v1/solar-design/horizon-shading-loss. An unpaid call returns the x402 payment terms and does not run.

Inputs: horizon (required), times, beamPoa, records, +3 more. Returns: sources, limitations, blockedHours, beamLossFraction, +1 more

solar-design_module-layout-fitFit modules onto a roof polygonA
Read-onlyIdempotent
Inspect

Maximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons. Price $0.04 USDC. POST /api/v1/solar-design/module-layout-fit. An unpaid call returns the x402 payment terms and does not run.

Inputs: roof (required), module (required), setback (required), gap, +3 more. Returns: best, sources, candidates, placements, +1 more

solar-design_module-spec-compareCompare module datasheet metricsA
Read-onlyIdempotent
Inspect

Normalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention. Price $0.02 USDC. POST /api/v1/solar-design/module-spec-compare. An unpaid call returns the x402 payment terms and does not run.

Inputs: modules (required), referenceCellTemp. Returns: modules, ranking, sources, limitations

solar-design_nec-690-currentCompute NEC 690.8 PV circuit currentA
Read-onlyIdempotent
Inspect

Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Price $0.02 USDC. POST /api/v1/solar-design/nec-690-current. An unpaid call returns the x402 payment terms and does not run.

Inputs: moduleIsc (required), edition, parallelStrings, continuousFactor. Returns: edition, sources, limitations, minOcpdRating, +3 more

solar-design_pan-ond-parseParse PVsyst PAN or OND text filesA
Read-onlyIdempotent
Inspect

Parse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object. Price $0.02 USDC. POST /api/v1/solar-design/pan-ond-parse. An unpaid call returns the x402 payment terms and does not run.

Inputs: content (required), fileType (required). Returns: raw, sources, normalized, limitations

solar-design_poa-irradiance-transposeTranspose GHI/DNI/DHI to plane-of-array irradianceA
Read-onlyIdempotent
Inspect

Compute plane-of-array irradiance with isotropic, Hay-Davies or Perez sky models and NREL SPA solar geometry from caller irradiance records. Price $0.04 USDC. POST /api/v1/solar-design/poa-irradiance-transpose. An unpaid call returns the x402 payment terms and does not run.

Inputs: tilt (required), azimuth (required), records (required), latitude (required), +7 more. Returns: records, sources, limitations

solar-design_row-spacingCompute inter-row spacing and GCRA
Read-onlyIdempotent
Inspect

Compute row height, shadow gap, row pitch and ground coverage ratio that avoid row-to-row shading at a design sun position. Price $0.02 USDC. POST /api/v1/solar-design/row-spacing. An unpaid call returns the x402 payment terms and does not run.

Inputs: tilt (required), moduleSlopeLength (required), sun, latitude, +5 more. Returns: gcr, sources, rowPitch, rowHeight, +4 more

solar-design_string-sizingSize PV module strings for an inverter MPPTA
Read-onlyIdempotent
Inspect

Compute minimum and maximum modules per series string and maximum parallel strings per MPPT from module temperature coefficients, site temperatures and inverter DC limits. Price $0.03 USDC. POST /api/v1/solar-design/string-sizing. An unpaid call returns the x402 payment terms and does not run.

Inputs: site (required), module (required), inverter (required). Returns: sources, feasible, iscAtTmax, vmpAtTmax, +8 more

solar-design_system-loss-stackCombine PVWatts system loss percentagesA
Read-onlyIdempotent
Inspect

Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Price $0.01 USDC. POST /api/v1/solar-design/system-loss-stack. An unpaid call returns the x402 payment terms and does not run.

Inputs: losses, useDefaultsForMissing. Returns: items, derate, sources, limitations, +1 more

solar-design_tariff-savingsEstimate bill savings under a TOU tariffA
Read-onlyIdempotent
Inspect

Compute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value. Price $0.03 USDC. POST /api/v1/solar-design/tariff-savings. An unpaid call returns the x402 payment terms and does not run.

Inputs: loadKwh (required), importPrice (required), generationKwh (required), exportMode, +5 more. Returns: savings, sources, exportKwh, importKwh, +5 more

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      A
      quality
      C
      maintenance
      Live and historical electricity prices, demand, generation mix and carbon intensity for 25 grid zones (US, Europe, GB, Australia). Hosted endpoint plus local stdio bridge; free sample mode, free API key, or x402 pay-per-call.
      6
      MIT
    Try in Browser

    Glama MCP Gateway

    Add one secure layer between your agents and this server.

    Resources