Update project settings
update_projectChange a project's name, status, visibility, signal flow, title-block fields, sizing standard and ampacity column, length unit, voltage-drop limits, or spare-terminal percentage.
Instructions
Rename, change status/visibility (Pro/Student only for private), default signal flow, title block fields, the sizing standard and its ampacity column, the length unit, the voltage-drop limits, or the spare-terminal percentage. title_block keys are the PDF template's field ids (built-in: drawingNo, drawnBy, customer, rev; custom template fields have their own ids).
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"project_id": "<project_id>"
},
"name": "update_project"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| flow | No | ||
| title | No | ||
| status | No | ||
| ambient_c | No | Ambient temperature the ampacity is corrected for, in °C (0–100). null = the default 40 °C (inside the enclosure). | |
| pid_sheets | No | PDF: P&ID sheets after the schematic (default on when the project has P&ID items). | |
| project_id | Yes | ||
| visibility | No | ||
| gauge_units | No | Wire gauge units in the grid, labels and PDF (default awg). In mm2 projects a bare gauge number means mm². | |
| harness_min | No | Fewest wires between two subsystems that make a harness (one trunk line). Default 3; null resets it. | |
| length_unit | No | Unit lengths are entered and shown in (default ft). Stored lengths are metres either way. | |
| pack_on_fix | No | fix_fanouts / Fix all re-pack the strips they touch. | |
| title_block | No | ||
| strip_naming | No | Tags for new strips: tb = TB1 / TB-PWR1 (default), iec = -X1, -X2. Existing strips keep their tags. | |
| strip_report | No | PDF: a terminal strip report page per strip (default true). | |
| default_block | No | Terminal block part (id or part number) new strips and strip terminals use when none is picked. null = generic block. | |
| sizing_column | No | Ampacity / insulation column of the standard (e.g. "75C", "105C-outside"); must be one of its columns. null = the standard's default. | |
| sizing_report | No | PDF: a sizing report page, one section per fuse or breaker (default on when any wire has sizing data). | |
| drop_total_pct | No | Total voltage-drop limit to the supply, in % of the signal's volts (0–100). null = the default 5 %. | |
| harness_report | No | PDF: a breakout table per harness (default true). | |
| drop_branch_pct | No | Branch voltage-drop limit — from the last fuse or breaker to the load — in % of the signal's volts (0–100). null = the default 3 %. | |
| gauge_on_labels | No | Printed wire labels include the gauge ("24VDC (+) 18 AWG BU"). Default false. | |
| sizing_standard | No | Sizing standard behind gauge and fuse suggestions (default nec). electronics: dev boards, breakouts and header pins, ampacity down to 30 AWG and no minimum size on DC or signal wires. | |
| default_pe_block | No | Same, for protective-earth strips. null = generic PE block. | |
| spare_terminal_pct | No | Packing (Clean up, fix_fanouts) appends this many spare terminals per strip, in % of its used terminals (0–50), empty and unlocked at the end. null = none. |