Skip to main content
Glama

HueMCP

An MCP server that lets Claude (or any MCP client) discover and control a Philips Hue bridge over its local CLIP v2 HTTP API. No cloud account needed — all traffic is LAN-local to your bridge.

Tool surface

Tool

Purpose

list_lights()

Every light with on/off, brightness, colour, owner device

list_rooms()

Rooms with their grouped_light_id and member devices

list_zones()

Zones with their grouped_light_id and member lights

list_scenes(group_id=None)

Scenes, optionally filtered to one room/zone

set_light(light_id, on?, brightness?, color_temp_mirek?, color_xy?, effect?, gradient_points?, gradient_mode?, timed_effect?, timed_effect_duration_ms?, transition_ms?)

Update one light

set_group(grouped_light_id, on?, brightness?, color_temp_mirek?, color_xy?, transition_ms?)

Update all lights in a room or zone

activate_scene(scene_id, brightness?, transition_ms?, action="active")

Recall a scene

identify_light(light_id)

Briefly pulse a light to locate it

bridge_info()

Basic identity of the bridge

get_resource(rtype, rid=None)

Generic escape hatch — raw bridge payload for any resource type

brightness is a percent (0–100). color_temp_mirek is a CIE mired value (typical range 153–500 ≈ 6500K–2000K — the per-light valid range is reported by list_lights()). color_xy is [x, y] in CIE 1931 space, clamped to the light's gamut.

list_lights() also reports per-light capability: effects.available (e.g. candle, fire, prism, sparkle, opal, glisten), timed_effects.available (sunrise, sunset), and — for gradient lightstrips — a gradient block with points_capable, pixel_count, and mode_values. Pass matching values to set_light to drive them: effect="candle", gradient_points=[[x,y], ...], timed_effect="sunrise", etc.

Related MCP server: Philips Hue MCP Service

Requirements

  • Python 3.10+

  • A Hue bridge reachable on your LAN

  • An application key — generated by pressing the link button and POSTing to /api (see "Bridge-side setup" below)

  • An MCP-capable client — these instructions assume Claude Code

Install

git clone <your-fork-url> HueMCP
cd HueMCP
python3 -m venv .venv
.venv/bin/pip install -e .
cp .env.example .env
# edit .env to set HUE_BRIDGE_HOST and HUE_APPLICATION_KEY

Smoke test:

.venv/bin/python scripts/smoke_test.py

Register with Claude Code (user scope, available in every project):

claude mcp add huemcp /absolute/path/to/HueMCP/.venv/bin/huemcp -s user

Bridge-side setup

  1. Find your bridge's IP at https://discovery.meethue.com or in the Hue app (Settings → My Hue System).

  2. Press the bridge's physical link button.

  3. Within 30 seconds, request an application key:

    curl -sk -X POST https://<bridge-ip>/api \
      -H 'Content-Type: application/json' \
      -d '{"devicetype":"huemcp#'"$(hostname)"'", "generateclientkey":true}'

    Copy the username value from the response into HUE_APPLICATION_KEY.

TLS

The bridge presents a self-signed certificate signed by the Philips Hue root CA. By default HUE_VERIFY_TLS=0 and the client skips verification — appropriate for a LAN-local device. To verify properly, install the Hue root CA into your trust store and set HUE_VERIFY_TLS=1, or pin a CA bundle by setting HUE_VERIFY_TLS=/path/to/ca.pem.

Configuration reference

Variable

Default

Purpose

HUE_BRIDGE_HOST

(required)

Hostname or IP of the bridge

HUE_APPLICATION_KEY

(required)

Application key from the bridge

HUE_VERIFY_TLS

0

0 skip, 1 system trust, or path to CA bundle

HUE_TIMEOUT

10

Per-request timeout in seconds

License

MIT — see LICENSE.

Available Tools

10 tools
activate_sceneA

Recall a scene — applies its stored light states to its target group.

  • action is active (default), dynamic_palette (cycles through the scene's palette), or static (one-shot apply with no dynamics).

  • brightness (0–100) overrides the scene's stored brightness.

  • transition_ms overrides the scene's default fade duration.

Inputs: scene_id (required), action, brightness, transition_ms. Returns: object

bridge_infoA

Return basic bridge identity (name, id, software version, time-zone).

Inputs: no named parameters. Returns: object

get_resourceA

Generic escape hatch — fetch a Hue resource by type, optionally by id.

rtype is a CLIP v2 resource type, e.g. light, room, zone, scene, grouped_light, device, bridge, motion, temperature, button, behavior_instance, smart_scene. Returns the raw bridge payload — useful when you need fields the higher-level tools don't expose.

Inputs: rtype (required), rid. Returns: object

identify_lightA

Make a light breathe (briefly pulse) so you can physically locate it.

Inputs: light_id (required). Returns: object

list_lightsA

List every light on the bridge with on/off state, brightness, colour, and owner.

owner.rid points to the parent device — useful when one device exposes multiple light services. To find which room a light belongs to, cross-reference the device id against list_rooms() children.

Inputs: no named parameters. Returns: object

list_roomsA

List rooms with their grouped_light_id (use with set_group) and member devices.

Inputs: no named parameters. Returns: object

list_scenesA

List scenes. If group_id is given (a room or zone id), only scenes targeting that group are returned. Use the returned id with activate_scene.

Inputs: group_id. Returns: object

list_zonesA

List zones with their grouped_light_id (use with set_group) and member lights.

Zones differ from rooms: a light belongs to exactly one room but can be in many zones (e.g. a "Downstairs" zone spanning Kitchen + Living room).

Inputs: no named parameters. Returns: object

set_groupA

Control all lights in a room or zone at once via its grouped_light_id.

Get this id from list_rooms() or list_zones() (grouped_light_id field). Same parameters as set_light, minus per-light effects.

Inputs: grouped_light_id (required), on, color_xy, brightness, +2 more. Returns: object

set_lightA

Update one light. Pass only the attributes you want to change.

Use list_lights() to discover what each light supports — it returns effects.available, timed_effects.available, and (for gradient strips) a gradient block with points_capable and mode_values.

  • brightness is 0–100 (percent). Setting brightness on an off light does NOT turn it on; pass on=True as well.

  • color_temp_mirek is the CIE mired value; the per-light valid range is reported by list_lights() as color_temp_range_mirek (commonly 153–500, i.e. ~6500K–2000K). Setting this clears any active colour.

  • color_xy is a 2-element list [x, y] in CIE 1931 colour space, clamped to the light's gamut. Setting this clears any active colour temperature.

  • effect is one of the values from effects.available (e.g. no_effect, candle, fire, prism, sparkle, opal, glisten). Pass no_effect to stop a running effect.

  • gradient_points is a list of [x, y] CIE 1931 points (typically 2–5, capped by the light's gradient.points_capable). Only meaningful for gradient-capable strips like the Hue Play Gradient lightstrip.

  • gradient_mode is one of the light's gradient.mode_values — interpolated_palette (default smooth blend), interpolated_palette_mirrored, random_pixelated, or segmented_palette.

  • timed_effect is sunrise, sunset, or no_effect. Use timed_effect_duration_ms to set how long the effect runs.

  • transition_ms is the fade duration in milliseconds for on/off, dimming, and colour changes.

Inputs: light_id (required), on, effect, color_xy, +7 more. Returns: object

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A4.4/5.0

    Scored across 10 tools

    Disambiguation5/5

    Each tool has a clear, distinct purpose: listing resources, controlling lights individually or by group, activating scenes, identifying devices, and fetching bridge info. The generic get_resource is explicitly an escape hatch for unmapped resources.

    Naming Consistency5/5

    All tool names follow a consistent verb_noun pattern (e.g., list_lights, set_light, activate_scene) using lowercase and underscores. No mixed conventions or vague verbs.

    Tool Count5/5

    10 tools is well-scoped for a Hue bridge server, covering key operations (listing, setting, scenes, identification) without unnecessary bloat or missing essentials.

    Completeness4/5

    Covers core lighting control well with CRUD-like operations but lacks dedicated tools for sensors or scene creation. The generic get_resource mitigates minor gaps, and scene management relies on the app, which is reasonable.

    Related MCP Connectors

    Related MCP Servers