Skip to main content
Glama
Almond MCP

Almond MCP

comfort_setpoints

Read-only

Calculates heating and cooling set-points from PMV for a given activity, clothing, and comfort category, returning operative temperatures for space conditioning.

Instructions

(BETA) Heating and cooling set-points from PMV for an activity and clothing: the lowest operative temperature that keeps PMV at or above the EN 16798-1 / ISO 7730 category's lower limit with the winter clothing (heating set-point), and the highest that keeps PMV at or below the upper limit with the summer clothing (cooling set-point). Category I +/-0.2, II +/-0.5, III +/-0.7, IV +/-1.0. Typical inputs: seated office 1.2 met, bedroom (sleeping) 0.8 met; clothing 1.0 clo winter, 0.5 summer; radiant_minus_air_k < 0 for cold windows. Use the result as heating_setpoint_c / cooling_setpoint_c, and state the assumptions with it.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "comfort_setpoints"
  }
}

Input Schema

NameRequiredDescriptionDefault
categoryNoII
air_speedNo
metabolic_rateNo
clothing_coolingNo
clothing_heatingNo
relative_humidityNo
radiant_minus_air_kNo

Output Schema

NameRequiredDescriptionDefault

No arguments

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.8.0

TDQS

A4.1/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnlyHint=true and openWorldHint=false, so safety is covered. The description adds real value beyond that: the BETA marker, the governing standards, the numeric category bands (I +/-0.2 through IV +/-1.0), and the expectation that assumptions be reported with the result. It does not, however, discuss edge cases such as invalid category strings or out-of-range metabolic rates, so it remains a moderate rather than rich behavioral disclosure.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The definition is front-loaded with the output semantics before the standards detail and typical inputs, and nearly every clause conveys information an agent needs (bands, defaults, sign convention, reporting instruction). The opening sentence is long and clause-heavy, which costs some readability, but there is no filler.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

An output schema exists, so return values need not be described, and the description correctly focuses on input semantics, standards, and the assumptions to report. With seven optional parameters and zero schema coverage, it covers five well but leaves air_speed and relative_humidity undefined, a small but real completeness gap for a physics calculation whose results are sensitive to those inputs.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 0%, so the description must carry the parameter burden, and it largely does: it explains category bands, metabolic_rate in met with typical values, clothing_heating and clothing_cooling in clo with seasonal defaults, and the sign convention for radiant_minus_air_k. Only air_speed and relative_humidity receive no explanation in either the schema or the description, leaving two of seven parameters semantically bare.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific computation (heating and cooling set-points derived from PMV) and states the exact semantics of each output: the lowest operative temperature keeping PMV at or above the category lower limit with winter clothing, and the highest keeping PMV at or below the upper limit with summer clothing. It is clearly distinguishable from generic siblings like thermal_comfort because it produces set-points under EN 16798-1 / ISO 7730 categories rather than comfort metrics.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

It gives concrete usage context: typical inputs for a seated office (1.2 met) and a bedroom (0.8 met), clothing values of 1.0 clo winter and 0.5 summer, and a negative radiant_minus_air_k for cold windows, plus an instruction to use the result as heating_setpoint_c / cooling_setpoint_c and to state assumptions alongside it. What is missing is any when-not guidance or explicit routing to an alternative tool for other comfort questions.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server

Other Tools