Skip to main content
Glama
SLogic16U3 MCP

SLogic16U3 MCP

by gjjisadog

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault
SLOGIC_CLINoAbsolute path to the native slogic-cli; an explicit wrong path causes an immediate error. Default lookup order: explicit path → package bin/ → source build/, build/Release/ → PATH.
SLOGIC_DATA_DIRNoCapture directory, defaults to ~/.slogic-mcp/captures.~/.slogic-mcp/captures

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": false
}
prompts
{
  "listChanged": false
}
resources
{
  "subscribe": false,
  "listChanged": false
}

Tools

Functions exposed to the LLM to take actions

NameDescription
logic_capabilitiesA

Return offline SLogic16U3 rate/channel limits, software triggers and storage limits. Highest channel index determines 4/8/16-channel mode; USB2 further limits rates.

logic_statusA

Enumerate only SLogic16U3 devices and their USB port, serial and link-specific rates. Does not start capture. USB accessibility does not establish exclusive readiness.

logic_captureA

Capture SLogic16U3 input signals using the official USB engine; defaults to CH0/CH1. Select physical channel numbers 0..15. 800 MHz requires ONLY CH0..CH3; 400 MHz requires ONLY CH0..CH7; CH8..CH15 require <=200 MHz on USB3. Windows conservative caps are 400/200/100 MHz. USB2 has further restrictions. At high rates suggest lower-numbered channels, retaining required signal/trigger channels. Never silently drop channels, remap probes, or reduce the requested rate. trigger: none/rising/falling/high/low/edge (software based, not hardware trigger). Trigger channel must be selected. pretrigger_percent is 0..90, threshold 0..6 V in 0.1 V steps. Maximum 32M samples. timeout_ms includes trigger wait and must exceed capture duration. If multiple devices exist, select a port from logic_status. Returns an ID for analysis, exact sample count and data integrity; failures are explicit.

logic_inspectC

Inspect exact digital transitions. max_samples limits the analysis window from sample 0; null analyzes the full capture. Last-byte padding is always excluded.

logic_measure_pwmA

Measure PWM frequency, duty, jitter and anomalies using ATK's analysis engine. max_samples defaults to the first 1M samples; null analyzes all. Duty is a 0..1 fraction. Static/insufficient signals return valid=false. Sampling resolution is reported in ns.

logic_measure_pairB

Measure active-HIGH complementary PWM deadtime and simultaneous-HIGH overlap. Does not invert active-LOW gate signals. Check measurement.valid and sampling resolution. max_samples=null analyzes the entire capture.

logic_measure_three_phaseC

Analyze three-phase PWM frequency and duty symmetry with ATK's analysis engine. Does not infer carrier synchronization without a reference signal.

logic_decodeB

Decode UART (8N1), I2C or SPI (8-bit, MSB-first, active-LOW CS) from verified captures. Select physical channels; SPI supports CPOL/CPHA 0 or 1. UART requires >=4 samples/bit. max_samples=null analyzes all; returned packets are bounded by max_packets (1..1000).

logic_assertB

Evaluate PWM tolerances over the ENTIRE complete capture; fail closed on invalid evidence. Duty is 0..1. Deadtime requires no_overlap_with_channel to identify the other active-HIGH gate. Rejects static/insufficient PWM, incomplete/corrupt artifacts and invalid complementary pairing. A pass applies to the recorded interval at the recorded sample resolution.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3.4/5.0

Scored across 9 tools

Disambiguation4/5

Each tool has a clearly distinct role: capabilities/status are informational, capture acquires data, inspect shows raw transitions, the three measure tools target distinct signal types (single PWM, complementary pair, three-phase), and decode/assert handle protocol and pass-fail logic. The only mild overlap is between logic_inspect (raw transitions) and the measure tools (derived metrics), but descriptions differentiate them well.

Naming Consistency4/5

All tools share the logic_ prefix and most use a verb_noun pattern (logic_capture, logic_inspect, logic_measure_pwm, logic_decode, logic_assert). The noun-only names logic_capabilities and logic_status are minor deviations but remain unambiguous.

Tool Count5/5

Nine tools is well-scoped for a logic analyzer: one acquisition tool, three distinct measurement tools, one decoder, one assertion tool, and two informational tools. Each earns its place without redundancy.

Completeness4/5

The surface covers discovery, acquisition, inspection, domain-specific measurements, protocol decode, and tolerance assertion, which is a coherent lifecycle for a logic analyzer. Minor gaps exist: no tool to list/export previously captured artifacts by ID, and no hardware-trigger or channel-configuration operations, though these are likely intentional scope limits.

Maintenance

ActivityMaintained