reirt-biobudget
This server does not currently have a deployable release on Glama. Follow the repository's setup instructions to install and configure it for your MCP client, including any required credentials and local dependencies.
reirt-biobudget
3D Deformable Biophysical Dose-Accumulation, DIR-Uncertainty Envelope, and Inverse Remaining-Budget Engine with Frontier Agent Harness for Multi-Course Re-Irradiation
Research & Clinical Safety Notice:
reirt-biobudgetis academic research and educational medical physics software. It is NOT a medical device and is not cleared or approved for clinical decision-making.
Why reirt-biobudget?
Multi-course re-irradiation is among the highest-risk workflows in modern radiotherapy (ESTRO/EORTC 2022). Standard clinical workarounds—naive rigid addition or single-point Excel EQD2 calculators—fail to capture 3D deformable image registration (DIR) uncertainty, multi-regime radiobiology (high-dose SBRT LQL, protracted/BID Lea–Catcheside repair, distal-edge variable proton RBE), and voxel-wise remaining safe physical dose headroom.
Consumer AI chat interfaces cannot solve this problem reliably: they cannot ingest 3D DICOM-RT/volumetric arrays, they hallucinate biological equivalence formulas and coordinate frames, and they cannot enforce formal physical invariants. reirt-biobudget separates deterministic physical ground truth from agentic clinical reasoning:
Proprietary Biophysical Core Engine (
src/reirt_biobudget/)Exact Forward & Analytical Inverse Multi-Regime Radiobiology (
radiobiology.py): Standard LQ (Fowler 1989), $C^1$-continuous Linear-Quadratic-Linear (Astrahan 2008), Lea–Catcheside incomplete repair $G(\mu T) + h_m$ (Dale 1985), and closed-form analytical inverse McNamara variable proton RBE from 3D $\mathrm{LET}_d$ (McNamara et al. 2015). Machine-precision forward–inverse residual (2.84e-14 Gy).3D Diffeomorphic DIR-Uncertainty Envelope & AAPM TG-132 Forensics (
dir_envelope.py): Stationary Velocity Field (SVF) scaling-and-squaring diffeomorphisms, physical-mm Jacobian determinant $J(\mathbf{x}) = \det(\mathbf{I} + \nabla\mathbf{u})$ & Inverse-Consistency Error (ICE) auditing, positivity-preserving trilinear dose warping, and TRE-calibrated 3D uncertainty envelopes ($p_{05}$, nominal, $p_{50}$, $p_{95}$, worst-case).3D Constraint-Safe Remaining Physical Dose Budget Optimizer (
budget_solver.py): Inverts remaining OAR EQD2 headroom into exact 3D Course-2 physical dose ceilings $D_{\mathrm{rem}}(\mathbf{x})$, enforcing strict minimum across overlapping OARs and ESTRO/EORTC 2022 Type 1/2 classification.SHA-256 Provenance Ledger & Hard Abstention Gate (
provenance.py): Refuses to output clinical numbers (AbstentionError) on missingFrameOfReferenceUID, non-diffeomorphic Jacobian folding ($J \le 0$), or excessive ICE ($> 5.0\ \mathrm{mm}$).
Frontier Agent Harness & MCP Server (
src/reirt_biobudget/harness/)Closed-Loop Adversarial Assumption Sweeper (
agent_orchestrator.py): Sweeps tissue recovery credit, DIR $\sigma_{\mathrm{TRE}}$, $\alpha/\beta$ epistemic bounds, and LQ vs. LQL regimes to identify the exact clinical tipping points and 2D safety phase boundaries (PASS/CAUTION/VIOLATION).Multi-Schedule & Multi-Modality Co-Designer: Compares 6 candidate Course-2 schedules (SBRT LQ/LQL, Hypo-IMRT, Conv-IMRT, McNamara Variable-RBE Proton, BID Lea–Catcheside) head-to-head.
Independent Critic-Verifier Gate: Re-evaluates every numeric claim from first principles before emitting the ESTRO/EORTC 2022 Markdown dossier and JSON provenance ledger.
JSON-RPC 2.0 MCP Stdio Server (
mcp_server.py): Exposes 5 typed, provenance-gated physics tools for frontier agents (reirt-biobudget mcp).
Related MCP server: GenPark Bio-Agent
Publication-Grade Visual Results (Public OpenKBP Clinical Benchmark pt_1)
All benchmark figures below are computed on real de-identified head-and-neck IMRT anatomy and 3D clinical dose (pt_1, 70 Gy / 35 fx) from the open-access OpenKBP dataset (Babier et al., Medical Physics 2021;48:5549–5561, DOI: 10.1002/mp.14845, CC BY 4.0), paired with an explicitly documented diffeomorphic SVF 18-month longitudinal follow-up benchmark.
Figure 1 — Tri-Planar CT, Prior EQD2, 3D DIR Uncertainty Spread, and Remaining Physical Budget

Figure 2 — Cumulative EQD2 DVHs with 90% DIR Uncertainty Envelopes & OAR Headroom

Figure 3 — Frontier Agent Harness: Adversarial Sensitivity Tornado & 2D Safety Phase Diagram

Figure 4 — Multi-Schedule & Multi-Modality Co-Design Matrix

Figure 5 — AAPM Task Group 132 Deformable Registration Quality & Topology Forensics

Quickstart
# 1. Create environment and install
uv venv --python 3.12 .venv
uv pip install --python .venv/bin/python -e ".[dev]"
# 2. Fetch real open-access OpenKBP clinical sample (CC BY 4.0, with SHA-256 manifest)
.venv/bin/python scripts/fetch_openkbp_sample.py --patient pt_1
# 3. Run full 3D engine + Frontier Agent Harness + 300-DPI academic figures
.venv/bin/reirt-biobudget run --patient-dir data/openkbp/pt_1 --out-dir outputs
# 4. Run full verification & audit test suite
.venv/bin/pytest -v tests/
# 5. Start JSON-RPC 2.0 MCP server for frontier agent harnesses
.venv/bin/reirt-biobudget mcpVerification, Audit & Documentation
Formal Mathematical Specification:
docs/ENGINE_SPECIFICATION.mdIndependent Verification & Audit Report:
docs/AUDIT_REPORT.mdGenerated ESTRO/EORTC 2022 Dossier:
outputs/reports/ESTRO_EORTC_ReIrradiation_Dossier.mdPublic Data Provenance, Licenses & BibTeX Citations:
DATA_SOURCES_AND_CITATIONS.md
Key Citations
Babier A et al. OpenKBP: The open-access knowledge-based planning grand challenge and dataset. Med Phys. 2021;48(9):5549–5561. DOI:
10.1002/mp.14845(CC BY 4.0 / MIT)Andratschke N et al. ESTRO/EORTC consensus on re-irradiation. Lancet Oncol. 2022;23(10):e469–e478. DOI:
10.1016/S1470-2045(22)00447-8Brock KK et al. AAPM Task Group 132: Use of image registration and fusion in radiotherapy. Med Phys. 2017;44(7):e43–e76. DOI:
10.1002/mp.12256Mayo CS et al. AAPM Task Group 263: Standardizing nomenclatures in radiation oncology. IJROBP. 2018;100(4):1057–1066. DOI:
10.1016/j.ijrobp.2017.12.013Nieder C et al. Update of human spinal cord reirradiation tolerance. IJROBP. 2006;66(5):1446–1449. DOI:
10.1016/j.ijrobp.2006.07.1383Sahgal A et al. HyTEC: Spinal cord dose tolerance to SBRT. IJROBP. 2021;110(1):124–136. DOI:
10.1016/j.ijrobp.2019.09.038Marks LB et al. QUANTEC: Use of normal tissue complication probability models in the clinic. IJROBP. 2010;76(3 Suppl):S10–S19. DOI:
10.1016/j.ijrobp.2009.07.1754Astrahan MA. Linear-quadratic-linear radiation dose-response with regard to hypofractionation. Med Phys. 2008;35(9):4161–4172. DOI:
10.1118/1.2969065Dale RG. Application of the linear-quadratic dose-effect equation to fractionated and protracted radiotherapy. BJR. 1985;58(690):515–528. DOI:
10.1259/0007-1285-58-690-515McNamara AL, Schuemann J, Paganetti H. Phenomenological RBE model for proton therapy. PMB. 2015;60(21):8399–8416. DOI:
10.1088/0031-9155/60/21/8399
License
Apache License 2.0 (see LICENSE). Upstream OpenKBP data retains its original CC BY 4.0 / MIT license (see data/openkbp/ATTRIBUTION.md and data/openkbp/UPSTREAM_LICENSE_OPENKBP.txt).
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
This server cannot be deployed
Maintenance
Related MCP Connectors
Deterministic physics runtime with a proof on every answer: 61 models, open and keyless over MCP.
Safety-first EVM and Bitcoin RPC tools for balances, contracts, blocks, and transactions
AI Reasoning Cache & Consensus Layer with 11 MCP tools via Streamable HTTP.
Seven hosted verification/lookup tools; hosted certification disabled. Opt-in stdio recording.
Related MCP Servers
- AlicenseBqualityBmaintenanceExposes the six-echelon quality pipeline over stdio JSON-RPC 2.0, enabling MCP clients to manage frozen baselines, HMAC-approved gates, phase role isolation, safe rollback, independent verification, W3C PROV-DM audit chains, and CAPA consolidation.101MIT

GenPark Bio-Agentofficial
AlicenseNot gradedqualityBmaintenanceExposes MCP tools that compute longevity and metabolic metrics (autophagy index, GKI, MAGE), cardio-renal biomarkers (BUN/creatinine ratio, cardiac output and TPR, nocturnal BP dipping), chronobiology estimates (DLMO, melanopic lux, caffeine clearance), plus neuro-recovery and biomechanics scores. Runs as a zero-dependency Python JSON-RPC 2.0 stdio server so any MCP-compatible client can query these physiological domain calculators.7MIT- AlicenseAqualityBmaintenanceExposes 24 evidence-grounded medical skills as JSON-RPC tools over stdio, letting agents run deterministic clinical calculators, PHI de-identification, negation-preserving multilingual parsing, and drug interaction checks locally with no token cost. It also enforces provenance and safety gates so high-risk dosing or prescribing decisions require documented clinical records rather than model inference.10728 npm1Apache 2.0
- AlicenseNot gradedqualityNot gradedmaintenanceEnables MCP-compatible clients such as Claude Desktop, Cursor, and Antigravity to invoke deterministic mathematical modeling and System 2 agent capabilities through a native STDIO JSON-RPC 2.0 server with zero external dependencies.MIT