mrphys-guard MCP Server
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
No arguments | |||
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
This server publishes no instructions, or was last inspected before Glama recorded them.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| mrphys_solve_3d_distortionC | Solve 3D MRI gradient nonlinearity (l<=5 solid spherical harmonics) and k-space Lorentz-sphere susceptibility B0 dipole convolution on a pelvic prostate MR-only phantom. |
| mrphys_audit_sct_and_ereC | Audit synthetic-CT (sCT) physics plausibility (bone-to-air swaps, missing metal, body-contour truncation) and compute 1.5T/0.35T Lorentz-force ERE boundary hotspot risk. |
| mrphys_verify_implant_cspB | Formally verify a multi-sequence MRI protocol against IEC 60601-2-33 / ASTM F2503 implant constraints (B0, dB/dx, B1+rms, SAR, slew rate, dB/dt, active scan time). |
| mrphys_codesign_safe_sequenceB | Run the closed-loop MR sequence & safety co-design agent with independent Critic-Verifier gate on a preset or custom high-risk clinical scenario. |
| mrphys_lookup_implant_profileA | Lookup built-in generic ASTM F2503 / IEC 60601-2-33 MR-conditional literature device profiles (pass device_id or omit to list all profiles). |
| mrphys_run_sobol_sensitivityB | Run exact Saltelli-Jansen QMC global Sobol' sensitivity analysis (S_1, S_T) over receiver bandwidth, air-cavity susceptibility, GNL residual, and sCT HU error. |
| mrphys_multibeam_ere_optimizeC | Evaluate multi-beam IMRT/VMAT opposing-beam Lorentz-force ERE cancellation and recommend lowest-ERE gantry angles at 1.5T or 0.35T. |
| mrphys_verify_multi_implant_cspC | Formally verify a multi-sequence MR protocol simultaneously across multiple co-existing implants, returning intersected limits, IEC PNS %, and UNSAT conflict cores. |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 8 tools
Each tool maps to a fairly distinct phase of MR physics/safety workflow (solve, audit, verify, co-design, lookup, sensitivity, optimize). The clearest overlap is mrphys_verify_implant_csp vs mrphys_verify_multi_implant_csp, and mrphys_audit_sct_and_ere shares ERE territory with mrphys_multibeam_ere_optimize, but descriptions clarify single-vs-multi-implant and audit-vs-optimize distinctions.
All eight tools use the mrphys_ prefix with a consistent snake_case verb_noun pattern (solve_, audit_, verify_, codesign_, lookup_, run_, multibeam_...). Compound nouns like verify_multi_implant_csp are long but follow the same convention throughout.
Eight tools is well-scoped for a specialized MR-physics safety verification server; each tool covers a distinct analysis stage with no filler. Nothing feels thin or bloated for the stated domain.
The surface covers simulation, audit, single/multi-implant CSP verification, co-design, sensitivity analysis, beam optimization, and implant profile lookup—a coherent safety lifecycle. Minor gaps: no ability to register/edit custom implant profiles (lookup is read-only over built-ins) and no explicit report/export or phantom-definition tool.