e3d_check_connection_pair

Read-onlyIdempotent

Compare two explicitly selected E3D P-points against a position tolerance in one UI-thread dispatch, reporting existence, read completeness, position delta, direction angle and PCREF correspondence.

Instructions

Read and compare two explicitly selected E3D P-points in one native E3D21 UI-thread dispatch. Requires both explicit element references, both point numbers and a caller-supplied position tolerance in mm. Optional first_expected_type and second_expected_type constrain each resolved endpoint to a Design type ShortName; only implicit TUBI has cross-type resolution from a shared BRAN/ELBO anchor. Reports each point's existence and read completeness, position delta against that tolerance, native PDIR direction dot product and angle, and each PCREF's resolution and exact correspondence to the opposite selected endpoint. Direction labels use a descriptive plus/minus 0.999 dot threshold, not an engineering rule. Preserves native PPBO bore, PPCO connection type, raw PCREF data and SPRE/CATR/CREF catalogue/connection reference evidence. Unknown or partial reads remain unknown; native evidence is not a dimensional, pressure-class, catalogue or engineering compatibility verdict. Does not dispatch PML commands, edit geometry, select CE, add display members or change the view.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "first_refno": "<first_refno>",
      "first_point_number": "<first_point_number>",
      "second_refno": "<second_refno>",
      "second_point_number": "<second_point_number>",
      "tolerance_mm": "<tolerance_mm>"
    },
    "name": "e3d_check_connection_pair"
  }
}

Input Schema

NameRequiredDescriptionDefault
first_refnoYesRequired explicit /NAME or =database/element reference for the first element.
second_refnoYesRequired explicit /NAME or =database/element reference for the second element.
tolerance_mmYesRequired finite position tolerance in millimetres; no default is applied.
first_point_numberYes
first_expected_typeNoOptional required Design type ShortName for the first element. Only implicit TUBI has cross-type resolution from a shared BRAN/ELBO anchor; other mismatches fail.
second_point_numberYes
second_expected_typeNoOptional required Design type ShortName for the second element. Only implicit TUBI has cross-type resolution from a shared BRAN/ELBO anchor; other mismatches fail.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A3.9/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Beyond the readOnly/idempotent/non-destructive annotations, the description discloses that all work happens in one native UI-thread dispatch, that direction labels derive from a descriptive ±0.999 dot threshold rather than an engineering rule, that unknown or partial reads stay unknown, and that raw PPBO/PPCO/PCREF/SPRE/CATR/CREF evidence is preserved. It also explicitly disclaims being a dimensional, pressure-class, catalogue or engineering compatibility verdict, which prevents an agent from over-reading results.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The core purpose is front-loaded and every sentence carries substantive information, with no filler. The trade-off is density: several sentences stack many clauses, making the block slower to scan than it needs to be.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With no output schema and seven parameters, the description does the work of describing what is reported: point existence and read completeness, position delta versus tolerance, PDIR dot product and angle, and each PCREF's resolution against the opposite endpoint. Only the precise shape of the returned payload is left unstated, a minor gap given the otherwise thorough coverage.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 71%, so most parameters are already documented structurally. The description restates the required set and echoes the expected_type constraint wording that already appears in the schema, adding little new, and it never explains what a point number denotes or how it is indexed for the two undocumented point-number parameters.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The opening sentence gives a specific verb and resource: read and compare two explicitly selected E3D P-points in a single native E3D21 UI-thread dispatch. The scope (exactly two points, explicit references, caller tolerance) is unambiguous. It does not name a sibling alternative such as e3d_connection_points for enumeration, so it falls short of the top mark.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Prerequisites are clear (both explicit element references, both point numbers, a caller-supplied tolerance), and the closing sentence carves out what the tool will not do: no PML dispatch, no geometry edits, no CE selection, no display changes. However, there is no explicit guidance on when to choose this over sibling read tools, or on how to obtain the point numbers and references beforehand, which the agent must infer.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.