Evaluates a multimeter cold resistance reading against OEM thresholds to diagnose whether a furnace hot surface igniter is functional, degraded, cracked, or shorted, with repair guidance.

Instructions

Evaluates an empirical digital multimeter cold resistance reading (in Ohms Ω at 65°F–75°F ambient) against OEM engineering failure thresholds to determine if a furnace hot surface igniter is functional, thermally degraded, cracked, or shorted.

WHEN TO USE THIS TOOL:

  • A user or technician has placed a digital multimeter across disconnected igniter wire leads and obtained an Ohm reading (e.g., 14.5 Ω, 48 Ω, 85 Ω, 120 Ω, or O.L / infinity).

  • The furnace inducer motor runs and the pressure switch closes, but the igniter fails to glow incandescent red (2,200°F) or drops flame rectification after a 4-second ignition trial.

  • You need to provide an immediate diagnostic status verdict (PASS, WARNING_DEGRADED, FAIL_OPEN_CIRCUIT, FAIL_HIGH_RESISTANCE, FAIL_SHORT_CIRCUIT) and actionable repair recommendations.

INPUT PARAMETERS:

  • measured_ohms: The multimeter resistance reading in Ohms (Ω). Use -1 or 999999 for open loop / infinity (O.L).

  • chemistry: The material construction ('silicon_nitride' for flat/slender dark gray ceramics, 'silicon_carbide' for porous black D-shaped/spiral ceramics, or 'unknown').

  • part_number: Optional specific OEM part number to compare against exact factory bench tolerances.

RETURN VALUE: Returns diagnostic status, pass/fail thresholds, root cause explanation (e.g., microscopic thermal fatigue micro-cracking), failure risk assessment, and recommended replacement steps with upgrade guidance.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "measured_ohms": "<measured_ohms>"
    },
    "name": "diagnose_igniter_resistance"
  }
}

Input Schema

NameRequiredDescriptionDefault
chemistryNoThe physical metallurgy/ceramic composition of the igniter. Silicon Nitride (Si3N4) operates at 11–17 Ω; Silicon Carbide (SiC) operates at 40–80 Ω.
part_numberNoOptional OEM or aftermarket part number (e.g., "LH33ZS004", "70W16") for exact factory specification comparison.
measured_ohmsYesThe measured cold electrical resistance across the igniter terminals in Ohms (Ω). For open circuit / infinite resistance (multimeter displays O.L or 1 .), enter 999999.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A4.3/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations at all, the description carries the full behavioral burden and does most of it: it discloses that analysis is against OEM engineering thresholds, enumerates the five possible verdicts, and describes the return payload (thresholds, root cause, risk, replacement steps). It omits any statement about the tool being purely analytical/non-mutating and about the chemical/threshold basis per chemistry beyond the enum, leaving modest gaps.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Front-loaded with the core purpose, then cleanly sectioned into when-to-use, inputs, and return value, so an agent can scan it quickly. It is somewhat verbose in places (the 2,200°F glow temperature and 4-second ignition trial are atmospheric detail rather than decision-relevant), but nothing is seriously redundant.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

There is no output schema, so the description must explain returns, and it does so adequately (status, thresholds, root cause, risk, replacement guidance). Inputs, enums, and sentinel handling are all addressed; the only substantive defect is the -1 sentinel that the schema forbids, which could cause a rejected call.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100% so baseline is 3, but the description adds real meaning: visual identification cues for chemistry ('flat/slender dark gray ceramics' vs 'porous black D-shaped/spiral') and the purpose of part_number as an exact factory-tolerance comparison. It is docked for instructing 'Use -1 or 999999 for open loop', which conflicts with the schema's minimum of 0 and its instruction to use 999999 only.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource: evaluates a measured cold resistance reading against OEM thresholds to classify an igniter as functional, degraded, cracked, or shorted. The scope (65°F–75°F ambient, disconnected leads) and the enumerated verdict set make it clearly distinct from the sibling lookup and resistance-calculation tools.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The 'WHEN TO USE THIS TOOL' block gives three concrete trigger scenarios (an Ohm reading in hand, no-glow with inducer running and pressure switch closed, need for an immediate verdict). It does not state when NOT to use it or point to a specific alternative such as lookup_furnace_igniter_specs when only a spec comparison is wanted, so it stops short of full routing guidance.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.