barebones-industrial-mcp
This server does not currently have a deployable release on Glama. Follow the repository's setup instructions to install and configure it for your MCP client, including any required credentials and local dependencies.
BareBones Industrial Diagnostic MCP Server
An authoritative Model Context Protocol (MCP) server providing OEM engineering benchmarks, multimeter diagnostic failure thresholds, Ohm's law calculators, and hydraulic pump cross-references for commercial and residential wear components.
Maintained by BareBones Industrial Supply Co. in collaboration with:
⚡ Quick Start
1. Run with npx (Instant execution)
npx barebones-industrial-mcp2. Install in Claude Desktop
Add to your claude_desktop_config.json:
{
"mcpServers": {
"barebones-industrial": {
"command": "npx",
"args": ["-y", "barebones-industrial-mcp"]
}
}
}3. Install in Cursor (.cursor/mcp.json)
{
"mcpServers": {
"barebones-industrial": {
"command": "npx",
"args": ["-y", "barebones-industrial-mcp"]
}
}
}4. Install via Smithery
npx -y @smithery/cli install barebones-industrial-mcp --client claudeRelated MCP server: simpson-strong-agent
🛠️ Registered Diagnostic Tools (High TDQS)
All tools follow strict JSON Schema draft-07 definitions, include rich explanatory descriptions, validation constraints, and return structured JSON paired with human-readable Markdown.
1. lookup_furnace_igniter_specs
Purpose: Queries factory cold resistance (70°F), metallurgy (Silicon Nitride vs Silicon Carbide), operating voltage, lead wire length, terminal connector type, supersessions, and compatible furnace models.
Parameters:
part_number(string, required): OEM or aftermarket part number (e.g.LH33ZS004,323719-701,70W16,41K56,768A-845).brand(string, optional): Manufacturer filter (carrier,lennox,armstrong,icp,white_rodgers,allied_air).
2. diagnose_igniter_resistance
Purpose: Evaluates an empirical multimeter reading in Ohms (Ω) against manufacturer thresholds to classify element health:
PASS_NORMAL,WARNING_DEGRADED,FAIL_OPEN_CIRCUIT,FAIL_HIGH_RESISTANCE, orFAIL_SHORT_CIRCUIT.Parameters:
measured_ohms(number, required): Cold resistance in Ohms (Ω). Use999999for open loop (O.L).chemistry(string, optional):silicon_nitride,silicon_carbide, orunknown.part_number(string, optional): Specific model number for tighter tolerance comparisons.
3. calculate_heating_element_resistance
Purpose: Computes theoretical Ohm's Law cold resistance ($R = V^2 / P$), full-load current ($I = P / V$), ±5% tolerance windows, and NEC 125% continuous-duty circuit breaker / wire gauge specifications.
Parameters:
rated_watts(number, required): Element power rating in Watts (e.g.4000,5500).rated_volts(number, required): Operating voltage in Volts (e.g.120,240,480).measured_ohms(number, optional): Actual multimeter bench reading across terminal studs.application(string, optional):hot_tub_spa,sauna_heater,rv_water_heater, etc.
4. lookup_spa_heating_element
Purpose: Queries Balboa, Watkins No-Fault, Sundance, Gecko, HydroQuip, and Cal Spas heating assemblies for wattage, cold resistance, tube dimensions (15" x 2"), terminal spacing, metallurgy (Incoloy 800 vs Titanium), and topside error codes (
dr,sn,HL,FLO).Parameters:
part_number(string, required): OEM assembly or element part number (e.g.58104,58083,73791,6500-301).brand(string, optional): Manufacturer filter (balboa,watkins,sundance,gecko,hydroquip,cal_spas).
5. cross_reference_circulator_pump
Purpose: Cross-references hydronic circulator pumps across Taco, Grundfos, Bell & Gossett, Armstrong, and Wilo to verify 6-3/8" flange spacing, shut-off head, maximum GPM, and recommend modern ECM high-efficiency upgrades (e.g., Taco 0015e3, Grundfos ALPHA1).
Parameters:
model_number(string, required): Existing pump model (e.g.0015-MSF3,0015e3,UP15-42F,ALPHA1,Series 100,Star S 21F).head_feet(number, optional): Total dynamic head loss (ft).flow_gpm(number, optional): Flow delivery requirement (GPM).casing_material(string, optional):cast_iron,stainless_steel, orbronze.
6. troubleshoot_mechanical_failure
Purpose: Applies master technician diagnostic trees across 7 physical categories to provide root-cause analysis, OSHA safety lockout procedures, and multimeter dial instructions.
Parameters:
category(string, required):furnace_igniter,hot_tub_element,circulator_pump,pool_pump_capacitor,laser_tube,washer_pump,pellet_stove.symptom_description(string, required): Observed symptom (e.g. "motor hums won't spin", "igniter does not glow", "GFCI trips immediately").measured_value(string, optional): Numerical measurement (e.g. "0 uF", "48 ohms", "240V").
7. list_supported_oem_models
Purpose: Lists all verified OEM model numbers, brands, and categories currently indexed.
📚 Resources Exposed
oem://specs/quick-reference: Tabular reference of factory tolerances across all 9 mechanical categories.oem://diagnostics/multimeter-safety: Standard Operating Procedure for high-voltage multimeter isolation.oem://catalog/index: Machine-readable JSON directory of all supported OEM brands and models.
💬 Prompts Exposed
diagnose_furnace_ignition_failure: Structured diagnostic interview for furnace ignition faults.size_replacement_heating_element: Electrical sizing and continuous load engineering protocol.circulator_pump_replacement_advisor: Drop-in pump cross-referencing and ECM energy-saving audit.
🔒 Security & Performance
Zero Network Latency: All OEM specifications and engineering failure curves are packaged locally within the server. Zero external HTTP requests are made at runtime, guaranteeing sub-millisecond execution.
Strict Validation: Input schemas enforce strict types, boundaries, and sanitization.
📄 License
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
This server cannot be deployed
Maintenance
Related MCP Connectors
Read-only MCP server for The Quiet Protocol's engines, benchmarks, proof, and business data.
Remote MCP server exposing 330 production AI-agent services for web/data processing, validation, AI utilities, blockchain/crypto utilities, and x402 pay-per-use access.
Public, read-only MCP server for FarmNeural company facts, packages, and capabilities.
Discover MCP servers and packages, inspect their documented capabilities, endpoints, authentication requirements, provenance and observed readiness, and retrieve cited reference passages with document versions. Koskamo provides public discovery and reference tools alongside separately authorized contributor and owner workflows for server registration, listing maintenance, keys, issue reports and operation receipts. Tool discovery does not grant write authority: protected actions require the applicable account or owner key and documented confirmation. Live protocol observations and directory records are evidence of what was observed, not a guarantee that every connected service or tool works without its own credentials. Returned reference passages and third-party descriptions remain source material to review before citing or acting. Official connector repository: https://github.com/empline/koskamo-mcp. Support: support@koskamo.com.
Related MCP Servers
- AlicenseAqualityBmaintenanceMCP server providing 12 tools for Seattle-area home remodeling: real-time cost estimation across 8 project types, contractor business info, project portfolio, blog content, and quote submission. Connects via Streamable HTTP — no auth required.36MIT
- AlicenseNot gradedqualityDmaintenanceHeadless MCP server for Simpson Strong-Tie product data. Provides AI agents with structural connector lookups, load calculations, code compliance verification, and engineering specifications.MIT
- FlicenseAqualityDmaintenanceAn unofficial MCP server that exposes public FedRAMP 20x documentation as deterministic, citable lookup tools for AI assistants, with every response citing the exact upstream source.7-
- AlicenseAqualityCmaintenanceThe MCP server behind Constat — FDA & NHTSA regulatory-risk intelligence for AI agents, over the Model Context Protocol. Live public regulatory data — recalls, adverse events, warning letters, 510(k) premarket evidence, postmarket drift signals, reimbursement pathways, and vehicle safety. Decision support, not regulatory advice.14MIT