calculate_foundation_and_slab_qto
Calculates foundation and slab quantity takeoffs for concrete, blinding, formwork, rebar, excavation, insulation, and contraction joints.
Instructions
[v0.4 Tool 14] Calculate the full structural and earthwork quantity chain for foundations, plinths,
and industrial floor slabs: structural concrete (m3), blinding concrete with lateral overhang (m3),
lateral formwork (m2), rebar/fiber tonnage (t), DIN 4124 prismoidal excavation (m3), plinth XPS (m2),
and saw-cut contraction joints (m).
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "calculate_foundation_and_slab_qto"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| elements | No | List of structural foundation or slab elements ('PAD_FOOTING', 'CUP_FOOTING', 'STRIP_FOUNDATION', 'PLINTH_WALL', 'RAFT_SLAB', 'INDUSTRIAL_FLOOR'). | |
| file_path_cad | No | Optional DXF/DWG path to extract foundation footprint polygons directly. | |
| working_space_m | No | Bottom pit working space around foundations in meters (default 0.50m per DIN 4124). | |
| batter_angle_deg | No | Pit excavation side slope angle in degrees (default 60.0 deg; 90.0 for vertical). | |
| foundation_layers | No | When `file_path_cad` is provided, CAD layers containing foundation footprints. | |
| blinding_overhang_m | No | Lateral overhang of blinding concrete on each side in meters (default 0.10m). | |
| unit_scale_to_meter | No | CAD drawing unit scale to meters (default 1.0). | |
| blinding_thickness_m | No | Blinding concrete thickness in meters (default 0.10m). | |
| default_cad_height_m | No | Structural height/thickness in meters for CAD-extracted footprints. | |
| default_cad_element_type | No | Element type assigned to CAD-extracted footprints. | PAD_FOOTING |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| warnings | No | ||
| breakdowns | No | ||
| working_space_m | Yes | ||
| batter_angle_deg | Yes | ||
| total_backfill_m3 | Yes | ||
| blinding_overhang_m | Yes | ||
| total_excavation_m3 | Yes | ||
| blinding_thickness_m | Yes | ||
| total_formwork_area_m2 | Yes | ||
| total_saw_cut_joints_m | Yes | ||
| total_perimeter_strip_m | Yes | ||
| total_xps_insulation_m2 | Yes | ||
| elements_processed_count | Yes | ||
| total_displaced_spoil_m3 | Yes | ||
| total_blinding_concrete_m3 | Yes | ||
| total_rebar_and_fiber_tonnes | Yes | ||
| total_structural_concrete_m3 | Yes |