Chinese-screen parameter lists
param_listConfigure one of five Chinese-screen parameter lists (voltage, current, OVP, OCP, cut-off current/time) and optionally make it active on an AX PP300S bench power supply.
Instructions
Write one of the five parameter lists (0..4) used by the Chinese screen: voltage, current, OVP, OCP, cut-off current (output off after the current stays below it for about 6 s; 0 = off) and cut-off time (output off when the accumulated on-time reaches it; fields not given are 0). select makes it the active list, sent after the values; it is refused when the list's values are unknown to this tool and a bench voltage limit is set or the output is on. These registers act only while the supply shows the Chinese screen.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| ocp | No | A | |
| ovp | No | V | |
| list | Yes | ||
| select | No | ||
| current | No | A | |
| voltage | No | V | |
| cut_time | No | "1h30m", "45m", "50s", "H:M:S" or "off" (99:60:60); hours 0..99, minutes/seconds 0..60; 0:0:0 refused | |
| max_wall | No | time limit for the call in s (default 30) | |
| cut_current | No | A (0 = off) |