Skip to main content
Glama

Eclipse Meridian MCP

Eclipse Meridian — governed telehealth operations — jurisdiction-gated encounters, signed-note integrity, PHI access evidence. Not a healthcare provider.

P0 build, synthetic-only. Status: built-uncertified / bench-pending (Verity bench runs separately; P0 claim ceiling is CERTIFIED (simulator) and no result here claims it yet).

The fused mechanism (spec §2): an encounter executes only when licensure × consent set × mandate verify at encounter time against the patient's attested location (Lock A); a note enters the record only as the exact fingerprint the treating clinician signed, with AI drafts cryptographically outside the record until then — UNSIGNED_DRAFT_NOT_RECORD (Lock B); every PHI read returns only mandate-granted field classes and seals a §164.312(b)-shaped, hash-chained, practice-held access record, granted or refused (Lock C).

Product law (§6.2): there is NO note_finalize tool — and no alias, synonym, or admin variant. Signature is the treating clinician's act in the system of record. The agent documentation surface is: create draft → fingerprint → request signature → read status → addendum-as-new-version. Post-signature change is always a new version + addendum, never a silent edit. There is no prescribing surface in any phase.

Surfaces

  • Meridian Core (server.py, MCP over stdio, stdlib only) — exactly 19 tools per spec §6.1: mandate_upsert, mandate_get, license_verify_at_encounter, consent_set_required, encounter_gate_check, encounter_schedule, encounter_start_gate, encounter_pack_get, intake_template_get, intake_status_get, note_draft_create, note_fingerprint_get, note_sign_request, note_signed_status_get, note_addendum_create, patient_context_get, appointment_get, access_pack_get, access_pack_verify.

  • Meridian Bridge (in meridian_engine.py) — HAPI FHIR R4 sandbox adapter only in P0 (local synthetic stand-in, no network code). Refuses live PHI without an executed BAA + complete subprocessor flow-down inventory: BAA_REQUIRED, no break-glass.

  • Standalone Tools (tools/): Encounter Gate (§9.1), Note Pin Verifier (§9.2), Access Ledger Verifier (§9.3), Policy Pack Workbench (§9.4) — jurisdiction rules live in versioned, counsel-signed DATA packs (data/policy_packs.json, synthetic jurisdictions labeled synthetic), never in code constants.

Related MCP server: HIPAA Compliance MCP

Guardrails baked in

  • License re-verified per encounter, never cached; location change booking→start re-runs the full gate (JURISDICTION_MISMATCH / CONSENT_SET_INCOMPLETE).

  • Recording requires affirmative consent from every participant or it doesn't start (RECORDING_CONSENT_MISSING); no ambient mode exists.

  • 42 CFR Part 2 + minor-restricted classes are restricted classes, default EXCLUDED from every mandate; FULL_CHART is not grantable to any P0 mandate (see spec-errata flag below).

  • Clinical requests return CLINICAL_REQUEST and route intact to the clinician queue with zero clinical content.

  • House reference guards pre-installed: coerce_int_param, parse_time (offset-mandatory), reference-type guard, container guard, deep-key scan for nested denylist inputs, verified-approval (Herald signature + customer-admin channel) for the T3-class mandate verb.

  • The clinician-sign simulator is bench equipment living only in tests/clinician_sign_simulator.py — it is not a tool, and the shipped engine/server/Tools contain no signing capability in any product file: no product file defines, imports, or references it (spec §12.1 P0-5, correction C3).

Spec-errata flags (for spec owner; spec not edited here)

  • §6.3 vs §13.3 tension on FULL_CHART: §6.3 says any FULL_CHART grant requires a separately counsel-reviewed mandate class and none ships in P0; §13.3's grantability test enumerates only scheduling/intake. Fix-round adjudication = the restrictive reading (§6.3): FULL_CHART ships in NO P0 mandate and mandate_upsert refuses it for every purpose set with MANDATE_TERM_NOT_GRANTABLE.

  • Spec-gap naming — PURPOSE_NOT_GRANTED: the §6.4 registry names PURPOSE_NOT_DECLARED only for an undeclared purpose. For a declared-but-not-granted purpose (wrong purpose for access_pack_get, or AUDIT_REVIEW outside the acting mandate's purpose_set), this build adds PURPOSE_NOT_GRANTED, following the registry's *_NOT_GRANTED convention (cf. FIELD_CLASS_NOT_GRANTED). Flagged for registry adoption at the next spec rev.

Run

python3 server.py            # MCP stdio server
python3 tests/test_meridian.py   # 85 checks: DT-1..DT-5, hostile shapes, locks, BAA, tools
python3 tests/test_meridian_fix_round.py   # 45 checks: B-MER-1..5 fix-round regressions (bench shapes)

State: $ECLIPSE_MERIDIAN_STATE or ./data/state.json. All fixtures are Synthea-shaped synthetic data; no real PHI anywhere in this tree.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      A
      quality
      C
      maintenance
      Provides cryptographic signing and verification for AI decisions to generate verifiable, Ed25519-signed receipts for compliance and auditing. It automatically maps AI actions to regulatory frameworks like HIPAA and SOX with high-performance, sub-3ms signing.
      4
      MIT
    • A
      license
      C
      quality
      B
      maintenance
      Enables unified orchestration of bioassay micro-validation, biopharma molecular docking/synthesis, and biorobotics surgical kinematics with HIPAA/GDPR PII scrubbing and metered billing.
      1
      6 npm
      MIT