Skip to main content
Glama

otii_power_on

Idempotent

Turn on the Otii main power output, optionally setting voltage and current limit first, and return an immediate reading with the active current limit.

Instructions

Turn on the Otii main power output, optionally setting the current limit and voltage first.

Returns a reading taken right after switching on, including the current limit in force.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "otii_power_on"
  }
}

Input Schema

NameRequiredDescriptionDefault
voltage_vNoOutput voltage in volts. Omit to keep the voltage already set on the Otii.
current_limit_aNoCurrent limit in amps, applied before switching on. Above it the Ace limits the current (voltage sags) rather than switching off. Omit to keep the limit already set.

Output Schema

NameRequiredDescriptionDefault

No arguments

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A3.8/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare idempotentHint=true and destructiveHint=false, so the safety profile is partly covered. The description adds useful detail about the post-switch-on reading and the current limit in force, but says nothing about preconditions such as what happens if the output is already on, or error behavior at the voltage/current bounds.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two short sentences with the core action front-loaded and the optional configuration clause immediately after. Nothing is redundant and nothing needs to be re-read.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

An output schema exists, so the description needn't detail return values, and it still gives a one-line preview of the reading. For a two-parameter, zero-required hardware control tool with annotations, this is nearly complete; only edge-case or error behavior is unaddressed.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, with both parameters fully documented, including the 25 V and 5 A limits and the 'Omit to keep' semantics. The description only restates that these are optional setup values, adding no syntax or behavioral meaning beyond the schema, so the baseline 3 applies.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description opens with a specific verb and resource: 'Turn on the Otii main power output,' and qualifies it with the optional voltage/current-limit setup. This is unmistakably distinct from otii_power_off, otii_measure, and otii_read, so an agent can select it without consulting the schema.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The phrase 'optionally setting the current limit and voltage first' implies when to supply the two arguments, and the schema's 'Omit to keep...' notes clarify the alternative. However, the description names no when-not conditions and does not reference sibling tools such as otii_power_off, leaving usage only implied.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server