logic-analyzer-ai-mcp
Click on "Deploy Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@logic-analyzer-ai-mcpcapture data from channel 0 for 10 ms and decode as I2C"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
Logic analyzer MCP
This project provides an MCP (Message Control Protocol) server and automation interface for Saleae logic analyzers. It enables remote control, automation, and integration of Saleae Logic devices and captures, making it easy to script, manage, and analyze logic analyzer data programmatically.
Features
Device configuration management
Capture configuration and execution
Data export in various formats
Logic file analysis and processing
Protocol decoding and visualization
Diagram generation and analysis
MCP (Message Control Protocol) server integration
Support for Logic 16 and other Logic 2 devices
Capture file parsing and analysis using python-saleae
Related MCP server: dwf-mcp-server
Requirements
Python 3.10 or higher
Saleae Logic 2 software installed
Python-saleae module
Logic 2 device (Logic 16, Logic Pro 8, etc.)
Installation
Clone the repository
Create and activate a virtual environment using uv:
# Create virtual environment
uv venv
# Activate virtual environment
# On Windows:
.venv\Scripts\activate
# On Unix/MacOS:
source .venv/bin/activateInstall dependencies using uv:
# Install all dependencies
uv pip install -e .If you encounter any issues with dependencies, you can try installing them directly:
# Install logic2-automation from GitHub
uv pip install git+https://github.com/saleae/logic2-automation/#subdirectory=python
# Install other dependencies
uv pip install grpcio protobuf grpcio-tools saleae mcp[cli] pytestNote: This project requires Python 3.10 or higher due to dependency requirements.
Usage
Running the MCP Server
To start the MCP server for remote control:
# Using uv (recommended)
uv --directory <project_path> run -m logic_analyzer_mcpNote: When using uv, make sure you have it installed and in your PATH. The --directory argument should point to the root directory of the project.
Current compatibility & Tested Version
This project is tested with Saleae Logic 1.2.40 for Windows.
Please use this version for best compatibility.
Other versions may work, but are not guaranteed or officially supported by this project.
Experimental note (alpha)
This is an experimental (alpha) version. The following MCP tool sequence has been tested and works for me:
saleae_connect (for Saleae Logic 1.2.40)
saleae_configure
saleae_capture — save capture in .logicdata format
parse_capture_file (optional)
get_digital_data_mcp
saleae_export (optional. use csv if needed)
Notes:
Make sure the Saleae Logic application is running and the scripting socket server is enabled before using these tools.
When calling saleae_capture, request the .logicdata format for best compatibility with the controller methods.
Troubleshooting & Important Notes
Logic Software Must Be Running:
Before using this automation interface, ensure that the Saleae Logic software is already running on your system. The automation scripts will attempt to connect to the running instance.
If the software is not running, the script may fail to connect, or may launch a new instance in simulation mode (which will not detect your real device).
Enable Scripting Socket Server:
In the Logic software, go to
Options>Preferences(orEdit>Preferences), and ensure that the "Enable scripting socket server" option is checked.The default port is usually 10429. If you change this, update your scripts accordingly.
If the scripting server is not enabled, the Python API will not be able to communicate with Logic, and you will see connection errors.
Device Not Detected:
Make sure your Logic device is connected to your computer and recognized by the Logic software before running any scripts.
If the device is not detected, check your USB connection and try restarting the Logic software.
Architecture Compatibility:
Ensure that both the Logic software and your Python environment are either both 32-bit or both 64-bit. Mismatched architectures can cause connection failures.
Permissions:
On some systems, you may need to run the Logic software and/or your Python script with administrator privileges to allow socket communication.
Supported Versions:
This project is designed for Saleae Logic 1.x/2.x automation. Some features may only be available in Logic 2.x with the appropriate automation API installed.
Note on Capture File Formats
.logicdata format is the recommended and best-supported file format for captures. All automation and parsing features are designed to work reliably with
.logicdatafiles..sal files (used by some older or alternative Saleae software) are currently known to have bugs and compatibility issues. Automated conversion or processing of
.salfiles may fail or require manual fixes. For best results, always use.logicdataformat for your captures.
API Reference
SaleaeController
The main controller class that provides high-level access to Logic 2 functionality.
Device Configuration Methods:
create_device_config(name: str, digital_channels: List[int], digital_sample_rate: int, analog_channels: Optional[List[int]] = None, analog_sample_rate: Optional[int] = None, digital_threshold_volts: Optional[float] = None) -> strCreates a new device configuration with specified channels and sample rates
Returns the configuration name
get_device_config(name: str) -> Optional[LogicDeviceConfiguration]Retrieves a device configuration by name
Returns None if not found
list_device_configs() -> List[str]Lists all available device configuration names
remove_device_config(name: str) -> boolRemoves a device configuration
Returns True if successful, False if not found
Capture Configuration Methods:
create_capture_config(name: str, duration_seconds: float, buffer_size_megabytes: Optional[int] = None) -> strCreates a new capture configuration with specified duration
Returns the configuration name
get_capture_config(name: str) -> Optional[CaptureConfiguration]Retrieves a capture configuration by name
Returns None if not found
list_capture_configs() -> List[str]Lists all available capture configuration names
remove_capture_config(name: str) -> boolRemoves a capture configuration
Returns True if successful, False if not found
Configurations:
Claude configuration (with uv run):
{
"mcpServers": {
"logic-analyzer-ai-mcp": {
"type": "stdio",
"command": "uv",
"args": [
"--directory",
"<path to folder>",
"run",
"-m",
"logic_analyzer_mcp"
]
}
}
}Claude configuration (direct usage):
{
"mcpServers": {
"logic-analyzer-ai-mcp": {
"type": "stdio",
"command": "python",
"args": [
"<path to folder>\\src\\logic_analyzer_mcp.py"
]
}
}
}Claude configuration (with uv run):
{
"mcpServers": {
"logic-analyzer-ai-mcp": {
"type": "stdio",
"command": "uv",
"args": [
"--directory",
"<path to folder>",
"run",
"-m",
"logic_analyzer_mcp"
]
}
}
}Logic2 parameter description
This project includes an opt-in experimental path for Logic2 automation. It is disabled by default. You can enable it in one of three ways:
CLI flag (recommended for one-off runs)
Example:
python -m logic_analyzer_mcp --logic2
Environment variable (convenient for CI / persistent shells)
Example (Unix):
LOGIC2=1 python -m logic_analyzer_mcp
Example (Windows PowerShell):
$env:LOGIC2='1'; python -m logic_analyzer_mcp
Programmatic API (when embedding the library)
Call the helper before registering tools:
from mcp_tools import set_logic2_enabled, setup_mcp_tools
set_logic2_enabled(True)
setup_mcp_tools(mcp, controller)
Or pass the explicit parameter to setup_mcp_tools:
setup_mcp_tools(mcp, controller, enable_logic2=True)
Notes
Default behavior: Logic2 experimental features are OFF. When disabled the code prefers controller-based or offline fallbacks.
Safety: Experimental features may change — enable intentionally and test with your environment before using in production.
Troubleshooting: If enabling Logic2 fails, check that the logic2-automation / python-saleae packages are installed and that the Saleae app is running and reachable.
Claude configuration (example)
Below is a minimal Claude MCP server configuration example you can adapt. Place this under your Claude configuration file or tooling settings.
{
"mcpServers": {
"logic-analyzer-ai-mcp": {
"type": "stdio",
"command": "uv",
"args": [
"--directory",
"<path to folder>",
"run",
"-m",
"logic_analyzer_mcp",
"--logic2"
]
}
}
}Notes:
Remove the
--logic2flag if you do not want experimental Logic2 tools enabled.Adjust
<path to folder>and otheruvarguments to match your environment.Use the
pythonbased configuration if you prefer to invoke the module directly instead of viauv.
Related MCP Connectors
Securely control computers you explicitly pair through files, terminals, processes, screenshots, desktop UI/input, clipboard, browser automation, diagnostics, and document tools.
Drive real devices from your AI Coding tool. Embed a client SDK (Unity, Godot, Flutter, iOS/macOS, Android, React Native, Web) in your app, then capture screenshots, traverse the UI tree, inject taps and key events, and run automated test tasks on the physical device over a secure relay.
Documentation for the Spektralwerk spectrometer SCPI API as a streamable HTTP MCP Server
Secure tunneling, reverse proxy and remote access for local applications.
Related MCP Servers
- AlicenseNot gradedqualityDmaintenanceEnables AI assistants to control Saleae Logic analyzers, capture and analyze digital/analog signals, and export data via MCP.MIT
- AlicenseNot gradedqualityCmaintenanceEnables control of Digilent WaveForms instruments (oscilloscope, AWG, logic analyzer) over USB, supporting devices like Analog Discovery 2/3 and Digital Discovery.3MIT
- FlicenseAqualityBmaintenanceEnables control of KingstVIS logic analyzers via the Socket API for sample configuration, triggering, data capture, export, and offline analysis including protocol decoding.261-
- AlicenseNot gradedqualityCmaintenanceEnables MCP clients to capture digital waveforms from an ALIENTEK USB logic analyzer, run 208 sigrok protocol decoders with stacked chains (like I2C→SSD1306 or UART→Modbus), and analyze or write .atkdl waveform archives offline without the device attached.1MIT