subsea-flow-calculator
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
No arguments | |||
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
This server publishes no instructions, or was last inspected before Glama recorded them.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| calculate_pipe_collapseA | Calculates subsea pipeline mechanical collapse pressure (Pc), plastic yield limit (Py), elastic buckling limit (Pe), allowable external pressure (Pca), and max operating water depth according to API RP 1111 (5th Edition, Limit State Design). Optionally evaluates site-specific water depth compliance and buckle arrestor requirements. |
| hydrostatic_pressureA | Calculates ultra-deepwater hydrostatic seawater pressure in Bar, MPa, and PSI from water depth (up to 3,500m / 11,500ft), including exact pressure gradients and ambient seabed thermocline temperature estimates. |
| hydrate_equilibrium_approxA | Estimates the natural gas hydrate formation equilibrium dissociation temperature (°C and °F) using the Towler-Mokhatab empirical model, calculating deepwater subcooling risk and thermal insulation requirements. |
| meg_inhibitor_dosageB | Calculates required thermodynamic hydrate inhibitor concentration (MEG or Methanol weight percentage in aqueous phase) and inhibitor-to-water mass ratio using the Hammerschmidt equation. |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 4 tools
Each tool targets a distinct physical quantity: inhibitor dosage, pipe collapse pressure, hydrostatic pressure, and hydrate equilibrium temperature. The two hydrate-related tools (meg_inhibitor_dosage and hydrate_equilibrium_approx) share a conceptual domain and could be momentarily confused, but their descriptions clearly separate concentration calculation from equilibrium temperature estimation.
Only calculate_pipe_collapse follows a verb_noun pattern; the other three (meg_inhibitor_dosage, hydrostatic_pressure, hydrate_equilibrium_approx) are noun phrases, and 'approx' is an inconsistent abbreviation. The set is readable but does not follow a single predictable convention.
Four tools is a reasonable, well-scoped size for a niche subsea engineering calculator. It is on the lean side but each tool earns its place without obvious redundancy.
Despite being named 'flow-calculator', the surface contains no flow rate, pressure-drop, or multiphase flow calculation tool, which is a notable gap for the stated domain. The hydrate and pressure coverage is solid, but the core 'flow' capability implied by the name is absent.