Skip to main content
Glama
tudadada

subsea-flow-calculator

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault

No arguments

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{}

Tools

Functions exposed to the LLM to take actions

NameDescription
calculate_pipe_collapseA

Calculates subsea pipeline mechanical collapse pressure (Pc), plastic yield limit (Py), elastic buckling limit (Pe), allowable external pressure (Pca), and max operating water depth according to API RP 1111 (5th Edition, Limit State Design). Optionally evaluates site-specific water depth compliance and buckle arrestor requirements.

hydrostatic_pressureA

Calculates ultra-deepwater hydrostatic seawater pressure in Bar, MPa, and PSI from water depth (up to 3,500m / 11,500ft), including exact pressure gradients and ambient seabed thermocline temperature estimates.

hydrate_equilibrium_approxA

Estimates the natural gas hydrate formation equilibrium dissociation temperature (°C and °F) using the Towler-Mokhatab empirical model, calculating deepwater subcooling risk and thermal insulation requirements.

meg_inhibitor_dosageB

Calculates required thermodynamic hydrate inhibitor concentration (MEG or Methanol weight percentage in aqueous phase) and inhibitor-to-water mass ratio using the Hammerschmidt equation.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

A3.5/5.0

Scored across 4 tools

Disambiguation4/5

Each tool targets a distinct physical quantity: inhibitor dosage, pipe collapse pressure, hydrostatic pressure, and hydrate equilibrium temperature. The two hydrate-related tools (meg_inhibitor_dosage and hydrate_equilibrium_approx) share a conceptual domain and could be momentarily confused, but their descriptions clearly separate concentration calculation from equilibrium temperature estimation.

Naming Consistency3/5

Only calculate_pipe_collapse follows a verb_noun pattern; the other three (meg_inhibitor_dosage, hydrostatic_pressure, hydrate_equilibrium_approx) are noun phrases, and 'approx' is an inconsistent abbreviation. The set is readable but does not follow a single predictable convention.

Tool Count4/5

Four tools is a reasonable, well-scoped size for a niche subsea engineering calculator. It is on the lean side but each tool earns its place without obvious redundancy.

Completeness3/5

Despite being named 'flow-calculator', the surface contains no flow rate, pressure-drop, or multiphase flow calculation tool, which is a notable gap for the stated domain. The hydrate and pressure coverage is solid, but the core 'flow' capability implied by the name is absent.

Maintenance

ActivityMaintained
ResponsivenessNo issues