Skip to main content
Glama
echonetlite-mcp

echonetlite-mcp

echonetlite-mcp

npm version License: MIT Node >= 18 TypeScript

An MCP (Model Context Protocol) server for ECHONETLite home automation — control air conditioners, discover devices, and read sensors via the Model Context Protocol.

ECHONETLite is a Japanese IoT protocol widely used in smart home devices, particularly HVAC systems by major manufacturers like Daikin, Panasonic, Mitsubishi Electric, and Toshiba.

Features

  • 🌡️ Real-time HVAC monitoring — temperature, humidity, operating status

  • ❄️ Full climate control — mode, fan speed, airflow direction, swing

  • 🔍 Network device discovery — find ECHONETLite devices via multicast UDP

  • 🔬 Node Profile probing — discover manufacturer, product code, UID, and all EOJ instances on any device

  • ⚡ Real-time notifications — async updates from device multicast listeners

  • 📖 MRA enrichment — Machine Readable Index integration for property names, descriptions, and value decoding

  • 🔬 EPC introspection — query property maps (STATMAP/SETMAP/GETMAP) with MRA-based names

  • 🏷️ Human-readable values — raw EPC values decoded to human-friendly format using MRA definitions

  • 🧩 EPC element parsing — parse complex object/array-type EPC values into named elements with MRA definitions

  • 🎯 Multi-EPC queries — query multiple EPC codes in a single request

  • 🔧 Generic EOJ support — set/query any ECHONETLite object by group/class/instance codes

  • 📦 TypeScript-first — full type definitions included

  • 🔌 MCP compatible — works with any MCP client (Claude Desktop, LM Studio, VS Code extensions, etc.)

Related MCP server: MQTT MCP Server

Prerequisites

  • Node.js 18+

  • An ECHONETLite-compatible device on the same local network

Installation

npm install echonetlite-mcp

Or use it as an MCP server directly:

git clone https://github.com/scottyphillips/echonetlite-mcp.git
cd echonetlite-mcp
npm install
npm run build

Configuration

The server defaults to communicating with a device at 192.168.1.6 on UDP port 3610, using multicast address 224.0.23.0:3610 for discovery and notifications.

Setting the Default Device IP

Option A: Environment variable (recommended)

# Windows CMD
set ECHONET_DEFAULT_HOST=192.168.1.10 && node dist/index.js

# PowerShell
$env:ECHONET_DEFAULT_HOST="192.168.1.10"; node dist/index.js

# Linux/macOS
ECHONET_DEFAULT_HOST=192.168.1.10 node dist/index.js

Option B: Edit config.ts

export const DEFAULT_HOST = '192.168.1.10';  // Change to your device IP

Lite Mode (Restricted Tool Set)

Enable Lite Mode to restrict exposed tools to a minimal subset. In lite mode, only these 6 tools are available:

Tool

Description

discover_devices

Discover all ECHONETLite devices on the local network

discover_nodes

Active Node Profile probing of a specific device

set_epc

Generic EPC setter for any EOJ instance

get_property_maps

Query STATMAP/SETMAP/GETMAP with MRA names

query_epc

Query EPC codes from device with decoded values

get_epc_definition

Get MRA definition for EPC codes without querying

All HVAC-specific tools (get_device_status, set_operation, set_temperature, etc.) are hidden in lite mode.

Enable Lite Mode:

# Windows CMD
set ECHONET_LITE_MODE=true && node dist/index.js

# PowerShell
$env:ECHONET_LITE_MODE="true"; node dist/index.js

# Linux/macOS
ECHONET_LITE_MODE=true node dist/index.js

When lite mode is enabled, the server logs (Mode: LITE) on startup. When disabled (default), it logs (Mode: FULL) with all tools available.

Per-Tool Override

Every tool accepts an optional host parameter to override the default for that specific call:

{ "name": "get_device_status", "arguments": { "host": "192.168.1.20" } }

Running the Server

# Build first
npm run build

# Run (stdio transport)
node dist/index.js

The server communicates via stdio, making it compatible with any MCP client.

Integration with AI Clients

Claude Desktop

Add to your Claude Desktop MCP configuration (claude_desktop_config.json):

{
  "mcpServers": {
    "echonetlite": {
      "command": "node",
      "args": ["/path/to/echonetlite-mcp/dist/index.js"],
      "env": {
        "ECHONET_DEFAULT_HOST": "192.168.1.6"
      }
    }
  }
}

LM Studio

LM Studio supports MCP servers via stdio transport. Create or edit the MCP config file:

Windows: %APPDATA%\lm-studio\mcp_config.json macOS/Linux: ~/.config/lm-studio/mcp_config.json

{
  "mcpServers": {
    "echonetlite-mcp": {
      "command": "node",
      "args": ["C:\\path\\to\\echonetlite-mcp\\dist/index.js"],
      "env": {
        "ECHONET_DEFAULT_HOST": "192.168.1.6"
      }
    }
  }
}

VS Code MCP Extension

Configure in your VS Code MCP extension settings:

{
  "mcp.servers": [
    {
      "name": "echonetlite",
      "command": "node",
      "args": ["/path/to/echonetlite-mcp/dist/index.js"],
      "env": {
        "ECHONET_DEFAULT_HOST": "192.168.1.6"
      }
    }
  ]
}

Available Tools

Note: When ECHONET_LITE_MODE=true, only discover_devices, discover_nodes, set_epc, get_property_maps, query_epc, and get_epc_definition are available.

Device Discovery

Tool

Description

Parameters

discover_devices

Discover all ECHONETLite devices on the local network via multicast

timeout (optional) - Discovery timeout in ms (default: 3000)

discover_nodes

Active Node Profile probing of a specific device — discovers manufacturer, product code, UID, and all EOJ instances with MRA enrichment

host (required), timeout (optional)

HVAC Control (Full Mode Only)

Tool

Description

Parameters

get_device_status

Get full status of the HVAC device

host (optional) - IP address

set_operation

Turn HVAC ON or OFF

host, operation ("on" / "off")

set_operating_mode

Set operating mode

host, mode ("auto" / "cool" / "heat" / "dry" / "fan_only")

set_temperature

Set target temperature

host, temperature (0-50°C)

set_fan_speed

Set air flow rate

host, speed ("auto" / "level1"-"level8")

set_airflow_vertical

Set vertical vane position

host, position ("upper" / "upper-central" / "central" / "lower-central" / "lower")

set_airflow_horizontal

Set horizontal vane position

host, position (28 positions: rc-right, left-lc, lc-center-rc, ...)

set_swing_mode

Set swing mode function

host, mode ("not-used" / "vert" / "horiz" / "vert-horiz")

set_auto_direction

Set automatic direction mode

host, mode ("auto" / "non-auto" / "auto-vert" / "auto-horiz")

set_silent_mode

Set silent operation mode

host, mode ("normal" / "high-speed" / "silent")

set_power_saving

Set power-saving mode

host, state ("saving" / "normal")

Sensor Readings (Full Mode Only)

Tool

Description

Parameters

get_temperatures

Get room + outdoor temperatures

host (optional) - IP address

get_humidity

Get room humidity

host (optional) - IP address

EPC Introspection & MRA Lookup (Available in All Modes)

Tool

Description

Parameters

get_property_maps

Query STATMAP/SETMAP/GETMAP with MRA-based property names and descriptions

host, eojgc, eojcc, eojInstance (all optional)

query_epc

Query one or more EPC codes from device, returns raw + human-readable decoded values

epcs (required), host, eojgc, eojcc, eojInstance (all optional)

get_epc_definition

Get MRA definition for EPC codes without querying the device — includes enum values, bitmaps, level ranges, $ref-resolved definitions

epcs (required), host, eojgc, eojcc, eojInstance (all optional)

set_epc

Generic EPC setter — set any writable property on any EOJ instance by hex value

host, eojgc, eojcc, eojInstance, epc, value

parse_epc_elements

Parse object/array-type EPC values into named elements with raw hex bytes per element — use after querying EPC data (e.g., 0xE2) to get structured breakdown

epc (required), rawHex (required), host, eojgc, eojcc, eojInstance, propertyName, shortName (all optional)

Available Resources

Resource URI

Description

device://status

Current HVAC status (updated via async notifications from multicast listener)

device://capabilities

Device property map (GETMAP, SETMAP, NTFMAP)

EPC Reference Table

EPC

Property

Access

Values

0x80

Operation status

Set/Get

0x30=ON, 0x31=OFF

0x8F

Power-saving operation

Set/Get

Saving/Normal

0xA0

Air flow rate (fan speed)

Set/Get

Auto=0x41, Levels=0x31-0x38

0xA1

Automatic airflow direction

Set/Get

Auto/Non-auto/Auto-vert/Auto-horiz

0xA3

Air swing mode

Set/Get

Not-used/Vert/Horiz/Vert-horiz

0xA4

Airflow direction (vertical)

Set/Get

Upper/Upper-central/Central/Lower-central/Lower

0xA5

Airflow direction (horizontal)

Set/Get

28 positions (rc-right, left-lc, center, etc.)

0xB0

Operation mode

Set/Get

Auto=0x41, Cool=0x42, Heat=0x43, Dry=0x44, Fan-only=0x45

0xB1

Automatic temperature control

Set/Get

—

0xB2

Normal/High-speed/Silent operation

Set/Get

—

0xB3

Set temperature

Set/Get

0-50°C (signed int)

0xB4

Set humidity in dehumidifying mode

Set/Get

—

0xBA

Room relative humidity

Get

Percentage

0xBB

Room temperature

Get

-127 to 125°C (signed int)

0xBE

Outdoor air temperature

Get

Signed int

0xC0

Ventilation function

Set/Get

—

0xC1

Humidifier function

Set/Get

—

0xCC

Special function setting

Set/Get

Clothes dryer, Mite/mold control, etc.

0xCF

Air purification mode

Set/Get

—

0x9D

STATMAP (access capability)

Get

Property access map

0x9E

SETMAP (settable properties)

Get

Settable property map

0x9F

GETMAP (readable properties)

Get

Readable property map

Example Prompts

Try these natural language prompts with your MCP client:

  • "Turn on my air conditioner" → calls set_operation with operation="on" (Full Mode)

  • "Set temperature to 23 degrees" → calls set_temperature with temperature=23

  • "Switch to cooling mode" → calls set_operating_mode with mode="cool"

  • "What are the current temperatures?" → calls get_temperatures

  • "Find all ECHONET devices on my network" → calls discover_devices

  • "Set fan speed to level 3" → calls set_fan_speed with speed="level3"

  • "What EPC codes can I query on this device?" → calls get_property_maps

  • "Get the current operation status and target temperature" → calls query_epc with epcs=["0x80", "0xB3"]

  • "What settings are available for operating mode?" → calls get_epc_definition with epcs=["0xB0"]

  • "Discover all nodes on 192.168.1.6" → calls discover_nodes with full MRA enrichment

  • "Parse the EPC 0xE2 value 0x00 0x0A 0xFF 0xFF for EOJ 0x02 0x88 0x01" → calls parse_epc_elements to split raw bytes into named elements

Project Structure

echonetlite-mcp/
├── src/
│   ├── index.ts              # MCP server entry point & tool definitions (~1200 lines)
node dist/index.js

MRA Integration

This server includes full MRA (Machine Readable Index) data integration:

  • Property names & descriptions — human-readable labels for each EPC code from MRA definitions

  • Value decoding — raw hex values decoded to meaningful strings/numbers using MRA type schemas

  • Enum/bitmap support — full enumeration of possible values with $ref resolution

  • Level ranges & number formats — signed/unsigned integers, fixed-point decimals

  • $ref resolution — external definition references from definitions.json resolved automatically

  • MRA enrichment in all tools — query_epc, get_property_maps, get_epc_definition return enriched responses

The MRA data enables intelligent discovery of what settings are available for any EPC code without needing to query the device first.

References

License

MIT License — see LICENSE for details.

Support

For issues, questions, or contributions, please open an issue on GitHub.

Buy Me A Coffee

Available Tools

14 tools
discover_devicesA

Discover all ECHONETLite devices on the local network via multicast

Inputs: timeout.

get_device_statusC

Get full status of the home air conditioner device

Inputs: host.

get_humidityB

Get the current room relative humidity reading

Inputs: host.

get_temperaturesB

Get both room temperature and outdoor temperature readings

Inputs: host.

set_airflow_horizontalB

Set the horizontal vane/airflow position (28 positions available)

Inputs: position (required), host.

set_airflow_verticalB

Set the vertical vane/airflow position

Inputs: position (required), host.

set_auto_directionC

Set the automatic airflow direction mode

Inputs: mode (required), host.

set_fan_speedB

Set the air flow rate (fan speed)

Inputs: speed (required), host.

set_operating_modeB

Set the HVAC operating mode (auto, cool, heat, dry, fan_only)

Inputs: mode (required), host.

set_operationB

Turn the home air conditioner ON or OFF

Inputs: operation (required), host.

set_power_savingB

Set the power-saving operation mode

Inputs: state (required), host.

set_silent_modeC

Set the silent operation mode

Inputs: mode (required), host.

set_swing_modeC

Set the air swing/swing mode function

Inputs: mode (required), host.

set_temperatureB

Set the target temperature (0-50°C)

Inputs: temperature (required), host.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    B3.4/5.0

    Scored across 14 tools

    Disambiguation5/5

    Each tool targets a distinct aspect of the air conditioner: discovery, status retrieval, humidity, temperatures, and various control parameters. There is no overlap or ambiguity.

    Naming Consistency5/5

    All tool names follow a consistent pattern: verb_noun using snake_case (e.g., discover_devices, get_status, set_temperature). The verbs (discover, get, set) are uniform and clear.

    Tool Count5/5

    14 tools cover essential operations for an air conditioner without being excessive. The scope is well-defined for a home automation HVAC control server.

    Completeness5/5

    The set covers all core CRUD-like operations: discovery, status reading, temperature/humidity sensing, and full control (on/off, mode, fan, airflow, power saving, silent). No obvious missing functionality.

    Maintenance

    ActivityInactive
    ResponsivenessOutdated data

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      B
      quality
      D
      maintenance
      Links IoT devices to AI large models using the MCP and MQTT protocols, enabling natural language control, real-time AI responses, and complex instruction execution for interconnected IoT devices.
      3
      373
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables LLM agents to securely monitor and control MQTT devices for building automation, industrial control, and smart home systems through a standardized MCP interface.
      25
      MIT
    • F
      license
      Not graded
      quality
      D
      maintenance
      An MCP server that enables LLMs to control Mitsubishi Electric AC units through MELCloud, supporting device listing, power on/off, temperature changes, and smart auto comfort mode.
      -