| Name | Required | Description | Default |
|---|---|---|---|
| SENSECA_PIN | No | PIN needed only if the instrument's protected mode is on. No default. | |
| SENSECA_PORT | No | Serial port for the Senseca instrument. Equivalent to the --port option. Default is auto-detect. | |
| SENSECA_LOG_LEVEL | No | Log level for the server. Equivalent to the --log-level option. Default is WARNING. | |
| SENSECA_ALLOW_WRITE | No | Enable write tools such as set_device_clock and set_location_name. Equivalent to the --allow-write option. Default is off. |
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
This server publishes no instructions, or was last inspected before Glama recorded them.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {
"listChanged": false
} |
| prompts | {
"listChanged": false
} |
| resources | {
"subscribe": false,
"listChanged": false
} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| read_temperatureA | Read the current temperature from the Pt100 probe, with unit and UTC timestamp. |
| read_resistanceA | Read the current Pt100 probe resistance in ohm (about 100 ohm at 0 °C). |
| sample_temperatureA | Record temperature readings over a period and return statistics plus all samples. Args: duration_s: Recording time in seconds (max 600). interval_s: Time between readings in seconds (min 0.5, the instrument's update rate). |
| get_device_infoB | Instrument model, serial number, firmware, clock (UTC) and battery level. |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 4 tools
Each tool has a clearly distinct role: two single-value reads for different physical quantities (temperature vs. resistance), one time-series sampling tool, and one device metadata tool. The boundary between read_temperature and sample_temperature is clear because one is a spot reading and the other records over time.
All names follow a consistent snake_case verb_noun pattern: read_temperature, read_resistance, sample_temperature, get_device_info. The verbs are predictable and match the operation type.
Four tools are well-scoped for a Pt100 sensor server with a small, focused read-only domain. Each tool earns its place without redundant operations.
The surface covers current temperature, raw resistance, time-series sampling with statistics, and device metadata, which covers the core monitoring workflow. Minor gaps such as calibration or configuration operations are reasonable for a read-only instrument server but prevent a perfect score.