Skip to main content
Glama

⚡🧠 eeg-mcp

Real-time EEG for AI agents — stream, replay, visualize, record, stimulate

PyPI Python Docs License

Documentation · Tutorial · Hardware · Safety · Tool Reference

A Model Context Protocol server that gives an AI agent one interface over the live EEG workflow: acquisition from ~66 BrainFlow boards, wall-clock replay of existing recordings, stateful online DSP, a live browser monitor, crash-safe recording, and gated stimulation output.

The offline counterpart is neuro-mcp (MNE processing, source imaging, BIDS/EHR storage). This is the real-time half — everything that has to happen while the signal is still arriving.

Concept

flowchart LR
    Researcher(["🔬 BCI Researcher"])
    Clinician(["🩺 Clinician"])
    Agent[["🤖 AI Agent"]]
    Server(("eeg-mcp<br/>FastMCP · 47 tools"))

    Clinician -- talks to --> Agent
    Researcher -- talks to --> Agent
    Agent -- MCP --> Server

    Server --> Acquire["Acquire<br/>66 boards · replay<br/>at true rate"]
    Server --> Process["Process<br/>stateful online DSP<br/>custom plugins"]
    Server --> Watch["Watch &amp; Record<br/>live monitor · HTML<br/>crash-safe .fif"]
    Server --> Stim["Stimulate<br/>LSL · TTL · TMS/tES<br/>3 safety gates"]

    classDef acq fill:#14b8a6,stroke:#0d9488,color:#fff
    classDef proc fill:#4f8cff,stroke:#2f5fbf,color:#fff
    classDef viz fill:#b06fe0,stroke:#7c3fae,color:#fff
    classDef stim fill:#eb5757,stroke:#b93b3b,color:#fff
    class Acquire acq
    class Process proc
    class Watch viz
    class Stim stim

Nobody calls a tool by hand — you talk to an agent in plain English and it drives the 47 tools underneath. The tutorial shows what that looks like end to end, with no hardware required.

Related MCP server: SupaUI MCP Server

What it does

📡 Stream

66 BrainFlow board identifiers — OpenBCI, Muse, ANT Neuro, g.tec, Mentalab and more — plus a synthetic board that needs no hardware. Samples land in a ring buffer filled by a background thread, so tool calls read a live view instead of blocking on a device. When BrainFlow itself can't reach a board — e.g. Muse on Windows, blocked by an upstream SimpleBLE bug — board="lsl" attaches to an existing LSL outlet instead.

⏪ Replay

Play an EDF/BDF/GDF/SET/FIF or BrainFlow CSV at the rate it was recorded, re-emitting annotations as events at their original timings. Adds speed, seek, pause and looping. A pipeline developed against a file runs unchanged against hardware.

👁 Visualize

A loopback-bound, token-gated live browser view: rolling traces, event markers, band power, per-electrode quality, and transport controls. Plus self-contained HTML reports — no CDN, no external assets, opens on an air-gapped machine.

💾 Record

Write continuously to MNE-native .fif with the event log attached as annotations, plus a metadata row in a store schema-compatible with neuro-mcp. Crash-safe: an interrupted session is recoverable.

🧩 Extend

Plug in your own real-time processor — feature extractor, classifier, artifact gate, or EEG tokenizer for sequence models — and it runs on the same footing as the built-ins, inside the acquisition loop. → Extending

⚡ Stimulate

One send_stim_event contract over pluggable backends: LSL for software, BrainFlow's marker channel for sample-aligned embedding, serial/TTL and templated ASCII for hardware including TMS and tES — behind three safety gates.

NOTE

One event log. Board markers, replayed annotations, dispatched stimulations and manual notes all land in the same table on the same clock, with absolute sample indices. A closed-loop run reconstructs afterwards with no clock join.

Install

conda create -n eeg-mcp python=3.11 -y && conda activate eeg-mcp
pip install eeg-mcp
pip install "eeg-mcp[lsl]"      # LSL marker outlets (PsychoPy, OpenViBE, ...)
pip install "eeg-mcp[serial]"   # serial/TTL trigger delivery to hardware

Register with an MCP client using an absolute path to the env's interpreter:

{
  "mcpServers": {
    "eeg-realtime": {
      "command": "/path/to/envs/eeg-mcp/bin/python",
      "args": ["-m", "eeg_mcp"]
    }
  }
}

Or with the Claude Code CLI:

claude mcp add eeg-realtime -- /path/to/envs/eeg-mcp/bin/python -m eeg_mcp

→ Full guide: Installation

Quick start

Ask your agent for the outcome; it picks the calls. No hardware required:

start_stream(session_id="s1", board="synthetic")
check_signal_quality(session_id="s1")          # before trusting anything
set_filters(session_id="s1", bandpass_low=1, bandpass_high=40, notch_freq=50)
get_band_power(session_id="s1", seconds=2)
start_monitor(session_id="s1")                 # → open the returned URL

Replay a real recording as if it were live, then keep the record:

inspect_recording(path="sub-04_rest.edf")
start_replay(session_id="r1", path="sub-04_rest.edf", speed=1.0)
get_events(session_id="r1", origin="annotation")
export_report(session_id="r1", notes="Routine review.")
flowchart LR
    A["start_stream<br/><i>or</i> start_replay"] --> B[check_signal_quality]
    B --> C[set_filters]
    C --> D["get_band_power<br/>get_psd"]
    C --> E[start_monitor]
    C --> P[attach_processor]
    A --> R[start_recording]
    D --> S[send_stim_event]
    P --> S
    R --> X[stop_recording]
    S --> X
    E --> X
    X --> Z[stop_stream]

    classDef hot fill:#14b8a6,stroke:#0d9488,color:#fff
    class A,X hot

Documentation

Guide

🚀 Installation

Environment, client registration, troubleshooting

📘 Tutorial

End to end, no hardware needed

⏪ Replay-Driven Development

Build against a recording, deploy live

🔁 Closed-Loop Neurofeedback

Feature → trigger, with a measured latency budget

🩺 Live Clinical Review

Visual review, annotation, reporting

⚡ Stimulation Protocols

TMS and tES through the safety gates

🧩 Extending

Write a custom processor or EEG tokenizer

🔌 Supported Hardware

All 66 boards, formats, stimulation transports

⚠️ Safety

Read before connecting a stimulator

🛠 Tool Reference

All 47 tools

The one design decision worth knowing

IMPORTANT

Filtering happens in the producer thread, not at query time.

A stateful IIR filter must see every sample exactly once, in order. The common shortcut — filtering each query window independently — restarts the filter at every window boundary and injects a transient each time. It is invisible in a band-power plot and fatal for anything phase-sensitive.

So the producer filters each chunk once as it arrives, carrying sosfilt delay-line state forward, and writes to a second ring buffer. Queries just read.

flowchart LR
    BF[Board / Recording] -->|poll| PR{{Producer thread}}
    PR -->|raw chunk| RB[(Raw ring buffer)]
    PR -->|stateful sosfilt| FB[(Filtered ring buffer)]
    PR -->|markers &amp; annotations| EL[(Event log)]
    PR -->|append| DISK[(.fif on disk)]
    PR -->|streaming| PL[Your processors]
    RB & FB & EL --> Q[MCP tools]

    classDef hot fill:#14b8a6,stroke:#0d9488,color:#fff
    class PR hot

The test suite asserts chunked filtering matches whole-signal filtering to 1e-9, and asserts as a control that the naive approach does not.

Consequence

Filters are causal

No zero-phase option — that needs future samples. stream_status reports group_delay_sec

Both buffers are kept

read_window(filtered=false) always gets raw signal, to check whether a feature is real or an artifact

Indices are shared

An event's sample_index means the same thing in either buffer

TIP

Budget a closed loop asgroup delay + poll interval + dispatch latency — measured at ~71 ms in the reference configuration. Good for neurofeedback; not adequate for phase-locked stimulation.

Stimulation safety

CAUTION

This software is not a medical device and has not been validated for clinical use. TMS and tES can cause harm, including seizure. Use only under a protocol approved by your ethics board, on a rig whose device-level interlocks are intact, with a trained operator present.

Three gates apply to every hardware backend:

#

Gate

Effect

1

Config

Hardware backends refuse to open unless the server was started with EEG_MCP_ALLOW_HARDWARE_STIM=1. An agent cannot set this.

2

Arming

arm_stim permits dispatch for a window that expires, so a stalled agent cannot resume and fire later

3

Limits

Intensity, duration and interval are clamped; violations raise rather than silently saturate

None of this replaces the interlocks on the device itself.

WARNING

The hardware backends are generic transports driven by command templates you supply from your device's manual — not vendor drivers, and none has been tested against a physical stimulator. A plausible-looking untested driver would be worse than none: it would fail silently while connected to something pointed at a person's head.

Start every protocol on backend="log", which accepts everything and emits nothing.

Verify

python testing/verify.py                    # core correctness
python testing/verify_recording.py          # recording + metadata store
python testing/verify_processing.py         # plugin processors
python testing/persona_bci_researcher.py    # engineer workflow
python testing/persona_clinician.py         # clinician workflow

All five drive the real server through FastMCP's in-memory client and assert against planted ground truth:

  • a spike planted at an annotation onset lands at t = 0 ± 0 ms in the extracted epoch — proving annotation timing, replay clock, ring-buffer indexing and epoch extraction all agree;

  • a deliberately broken plugin cannot stop acquisition — throughput holds at 1.0;

  • hardware stimulation is refused while the config gate is unset.

→ What is and is not covered — including an honest list of what has never been tested against real hardware.

License

BSD-3-Clause. See LICENSE and NOTICE.

⬆ back to top · Part of the AImplifier neuro toolchain · sibling project neuro-mcp

Available Tools

47 tools
arm_stimA

Permit hardware stimulation for a bounded window.

Arming expires deliberately: an agent that stalls mid-protocol should not be able to resume and fire a stimulator minutes later without a fresh, explicit decision. Re-arm as needed, or disarm the moment a block ends.

Inputs: session_id (required), backend, ttl_sec. Returns: object

attach_processorA

Attach a processor to a session.

A streaming processor runs inside the acquisition loop on every chunk, so it reacts within one poll interval without an agent round-trip -- that is how closed-loop logic gets fast. The cost is that slow code stalls acquisition; processor_status reports each one's mean and worst-case time so you can see whether yours is affordable.

Non-streaming processors do nothing until you call run_processor.

Inputs: processor (required), session_id (required), params. Returns: object

attach_stim_backendA

Bind a stimulation target to a session and open its transport.

Start with backend='log' to rehearse a protocol with no output at all, then switch once the timing looks right.

Inputs: session_id (required), backend, options, make_default. Returns: object

check_signal_qualityA

Per-channel health check: amplitude, flat/railed detection, line noise.

Call this before trusting any real-time feature, and definitely before driving stimulation from one. A flat or railed electrode poisons an average reference and a band-power threshold without changing anything you would notice in the feature value itself.

Inputs: session_id (required), seconds, line_freq. Returns: object

clear_eventsA

Empty the session's event log without stopping the stream.

Useful between blocks of an experiment. The signal buffer is untouched.

Inputs: session_id (required). Returns: object

clear_filtersA

Remove the filter chain; reads return raw signal again.

Inputs: session_id (required). Returns: object

detach_processorB

Remove a processor from a session and release its state.

Inputs: processor (required), session_id (required). Returns: object

detach_stim_backendC

Close and remove a stimulation backend from a session.

Inputs: backend (required), session_id (required). Returns: object

disarm_stimC

Revoke permission to stimulate. Takes effect immediately.

Inputs: session_id (required), backend. Returns: object

export_reportA

Write a full review page: traces, spectrum, quality, and the event log.

The one artefact to keep from a session. Everything is inlined, so it opens on any machine, needs no internet, and still renders years from now.

Inputs: session_id (required), notes, seconds, include_spectrum. Returns: object

get_band_powerA

Band power over the most recent window, per channel and averaged.

The workhorse feature for neurofeedback and closed-loop triggering. Prefer the _rel (relative) values for thresholds: they are largely immune to impedance drift, so a threshold set at the start of a session still means the same thing an hour later.

Inputs: session_id (required), bands, seconds, channels, +2 more. Returns: object

get_channelsB

List the channels a session is producing, with their buffer index.

Inputs: session_id (required). Returns: object

get_epoch_around_eventA

Extract the signal window around an event that already occurred.

Online epoching: use it to inspect the response to the most recent stimulus, or to verify that a stimulation artifact lands where you expect. The event must still be inside the ring buffer -- for a default 60 s buffer, that means within the last minute.

Inputs: session_id (required), tmax, tmin, label, +3 more. Returns: object

get_eventsA

Read the session's event log.

Everything lands here on one clock: board markers, annotations re-emitted by a replay, stimulation commands we dispatched, and manual notes. That is what makes a closed-loop run reconstructible afterwards without joining clocks.

Inputs: session_id (required), label, limit, origin, +1 more. Returns: object

get_processor_outputC

Read a streaming processor's recent outputs.

Inputs: processor (required), session_id (required), limit. Returns: object

get_psdA

Power spectral density over the most recent window.

Use when band power is too coarse -- to find a peak alpha frequency, confirm a stimulation artifact, or check whether a notch actually removed the mains.

Inputs: session_id (required), fmax, seconds, channels, +2 more. Returns: object

get_tokensA

Read discrete tokens from a tokenizing processor.

For feeding EEG into sequence models. Returns both the grouped tokens (one group per window) and a flat sequence, plus the vocabulary size and the channel/band layout each position corresponds to.

Works with any attached processor exposing token_history -- the built-in band_tokenizer is a starting point, and your own tokenizer plugs in the same way.

Inputs: session_id (required), limit, processor. Returns: object

inspect_recordingA

Open a recording and describe it without starting playback.

Use this before start_replay to see how long the file is, what channels it has, and which annotations will be re-emitted as events during replay.

Inputs: path (required), board, max_events. Returns: object

list_boardsA

List every board BrainFlow can acquire from, with ids and sampling rates.

Start here when you do not know what hardware is available. Two entries need no hardware at all: SYNTHETIC_BOARD generates a signal for development, and PLAYBACK_FILE_BOARD replays a BrainFlow CSV.

Returns: Board names, numeric ids, sampling rates and EEG channel counts.

Inputs: no named parameters. Returns: object

list_monitorsA

List live monitors currently serving, with their URLs.

Returns: Active monitors and the URL for each.

Inputs: no named parameters. Returns: object

list_processorsA

List real-time processors available to attach, and where they came from.

Built-ins are always present. Your own appear here once the server environment points at them -- via the eeg_mcp.processors entry point, EEG_MCP_PLUGINS, or EEG_MCP_PLUGIN_DIR. They cannot be loaded from a tool call, because importing a module executes it and that would make arbitrary code execution reachable from a model.

Returns: Available processors with their parameters, plus any plugin that failed to load, so a typo is visible instead of silently missing.

Inputs: no named parameters. Returns: object

list_recording_eventsA

List all events present in a replay session's source file.

Distinct from get_events: this is the complete event list from the file, including events that have not been reached yet. get_events returns only what has actually been emitted so far.

Inputs: session_id (required), max_events. Returns: object

list_recordingsB

List recordings in eeg-mcp's own metadata store, newest first.

This store belongs to eeg-mcp alone. Analysis tools read from it -- the schema is compatible with neuro-mcp's, so it can open this database and understand every row -- but nothing else writes to it.

Inputs: limit, subject. Returns: object

list_sessionsA

List all active stream and replay sessions with a one-line summary each.

Returns: Session ids with their source kind, running state, and buffer fill.

Inputs: no named parameters. Returns: object

list_stim_backendsA

List stimulation targets, their options, and which ones drive hardware.

Software backends ('log', 'lsl', 'brainflow_marker') are always available. Hardware backends ('serial_ttl', 'tms', 'tes', 'template_serial') require the server to have been started with EEG_MCP_ALLOW_HARDWARE_STIM=1, and must be armed before each session of use.

Returns: The backend catalogue and the currently configured safety ceilings.

Inputs: no named parameters. Returns: object

log_eventA

Record an event against the stream's clock.

For anything the server did not generate itself: a task onset, a subject report, an experimenter note. Stimulation commands are logged automatically by send_stim_event, so do not log those by hand.

Inputs: label (required), session_id (required), value, payload, +2 more. Returns: object

plot_spectrumC

Render the power spectrum and band composition as a standalone HTML file.

Inputs: session_id (required), fmax, seconds, channels, +1 more. Returns: object

plot_streamA

Render the recent signal as a standalone HTML file and return its path.

A frozen snapshot, unlike start_monitor -- use it to keep a record, attach to a note, or share. The file inlines everything and needs no internet.

Inputs: session_id (required), seconds, channels, filtered, +1 more. Returns: object

processor_statusA

Report attached processors, their health, and their cost.

mean_ms and max_ms are the numbers to watch for a streaming processor: if max_ms approaches the poll interval (50 ms by default) it is starving acquisition, which shows up as throughput_ratio below 1.0 in stream_status. A processor that raises 10 times is disabled automatically rather than being retried forever inside the producer loop.

Inputs: session_id (required). Returns: object

read_windowA

Read the most recent samples from the buffer.

Returns filtered signal when a filter chain is set (see set_filters), otherwise raw. Long windows are decimated to max_samples per channel so the response stays readable -- for numeric work prefer get_band_power or get_psd, which compute on the full-resolution data.

Inputs: session_id (required), seconds, channels, filtered, +2 more. Returns: object

recording_statusB

Report whether a session is recording, and how much has been written.

Inputs: session_id (required). Returns: object

recover_recordingA

Finish a recording whose process died before it could be closed.

Samples are appended to disk as they arrive and the header is written up front, precisely so an interrupted session is not lost. Point this at the orphaned .eegmcp.json header to convert what was captured into a .fif.

Events are not recoverable -- they lived in memory -- so the resulting file carries signal without annotations.

Inputs: header_path (required), keep_sidecar. Returns: object

replay_controlA

Pause, resume, seek, or change the speed of a replay session.

Inputs: action (required), session_id (required), speed, position_sec. Returns: object

reset_processorsA

Clear accumulated processor state and outputs, without detaching them.

Useful between experimental blocks, and after a replay seek, so a rolling window does not straddle the discontinuity.

Inputs: session_id (required). Returns: object

run_processorA

Run a processor once on the most recent window, on demand.

Works for both modes: for a non-streaming processor this is the only way to execute it, and for a streaming one it is a way to get an answer right now rather than waiting for its next scheduled output.

Inputs: processor (required), session_id (required), seconds, filtered. Returns: object

send_stim_eventA

Deliver one stimulation command, and log it against the EEG clock.

The event is written to the session log whether the transport succeeds or fails -- a failed stimulation attempt matters just as much to the record. When the acquisition source supports markers, the same event is also punched into the stream itself so the recording is self-describing.

Inputs: label (required), session_id (required), kind, unit, +7 more. Returns: object

send_stim_trainA

Deliver a regular train of pulses, blocking until it completes.

For rTMS bursts and repeated cues. The call holds until the train finishes, so it is capped at 1000 pulses and 60 seconds total; build longer protocols from several calls so there are decision points in between.

Every pulse is logged individually, so the event log reconstructs the exact delivered timing rather than the intended timing.

Inputs: label (required), n_pulses (required), session_id (required), interval_ms (required), +4 more. Returns: object

set_filtersA

Install a stateful online filter chain on a running stream.

The chain filters continuously in the background as samples arrive, carrying filter state across chunk boundaries. This matters: filtering each query window independently would inject a transient at every boundary and corrupt any phase-sensitive measure. Filtered output goes to a second buffer, so raw signal remains available via read_window(filtered=False).

These are causal filters -- there is no zero-phase option, because that needs future samples. Check group_delay_sec in the response to know how far behind real time your filtered features are.

Inputs: session_id (required), order, filters, notch_freq, +2 more. Returns: object

start_monitorA

Open a live browser view of a running session and return its URL.

Serves a rolling traces view with event markers, band power and per-channel quality, refreshing continuously. This is the tool for "let me watch the recording" -- a static plot cannot answer whether the signal is good now.

With allow_control (the default) the page also carries transport buttons: play/pause, restart, skip, speed, stop, mark an event, and save a report. Pass allow_control=false for a strictly read-only view, e.g. when showing the screen to someone who should not be able to alter the run.

The page is bound to 127.0.0.1 only and requires a random per-monitor token, so it is not reachable from the network. It is still unencrypted: do not expose it through a tunnel or reverse proxy.

Inputs: session_id (required), port, refresh_ms, window_sec, +1 more. Returns: object

start_recordingA

Begin writing the live signal to disk, continuously.

Call this as soon as the session starts if you intend to keep the data. The ring buffer only holds the last minute or so, so anything not recorded is gone -- a session streamed for an hour without recording leaves nothing but whatever reports you exported.

The raw, unfiltered signal is written. Filter settings are stored alongside it so a filtered view is reproducible; the amplifier's actual output is not reconstructible from anything else.

Inputs: session_id (required), run, name, task, +4 more. Returns: object

start_replayA

Replay a recording against a wall clock, re-emitting its events.

This is the safe way to build a real-time pipeline: the session behaves exactly like a live stream -- same buffering, same chunked delivery, same tools -- so code developed here runs unchanged against hardware. The recording's annotations arrive in the event log at their original timings.

Inputs: path (required), session_id (required), loop, board, +4 more. Returns: object

start_streamA

Open a board and begin buffering EEG in the background.

Data flows into a ring buffer from a background thread as soon as this returns, so a subsequent read_window will have samples waiting. The session keeps running until stop_stream is called.

Inputs: session_id (required), board, params, channels. Returns: object

stim_statusA

Report attached stimulation backends, arming state, and dispatch counts.

Inputs: session_id (required). Returns: object

stop_monitorB

Close a session's live monitor and free its port.

Inputs: session_id (required). Returns: object

stop_recordingA

Finish the recording, write the .fif, and register it for analysis.

The event log becomes annotations inside the file, and -- unless you pass register=false -- a row is inserted into the metadata store with the subject, task, run and provenance, so neuro-mcp can find and open it.

Inputs: session_id (required), register, keep_sidecar. Returns: object

stop_streamA

Stop a stream and release the board, serial ports, and LSL outlets.

Always call this when finished. A board left prepared can block the next process from acquiring the device.

Inputs: session_id (required). Returns: object

stream_statusA

Health and timing report for a session.

The fields that matter for closed-loop work: throughput_ratio below 1.0 means the producer is not keeping up and samples are being dropped; filters.group_delay_sec is how far behind real time a filtered feature is; last_error explains a stopped producer.

Inputs: session_id (required). Returns: object

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.7/5.0

    Scored across 47 tools

    Disambiguation5/5

    Every tool targets a distinct resource and action, with nuanced distinctions clearly explained (e.g., get_events vs list_recording_events, start_stream vs start_replay). No two tools appear to do the same thing, even in dense areas like stimulation and processor management.

    Naming Consistency5/5

    Tool names follow a consistent snake_case verb_noun pattern (list_, get_, start_, stop_, attach_, detach_, set_, clear_) with a predictable 'status' suffix for health-check tools (stream_status, processor_status). No mixing of conventions or vague verbs.

    Tool Count2/5

    At 47 tools, the surface is far above the 'heavy' threshold of 25. While the broad scope of a full EEG platform justifies many operations, the sheer number is overwhelming for an agent to navigate efficiently and risks tool-selection errors in practice.

    Completeness5/5

    The tool set covers the entire EEG workflow: acquisition, filtering, analysis, recording, replay, stimulation, monitoring, events, and processors. Lifecycle actions have counterparts (start/stop, attach/detach, arm/disarm), and there are no obvious dead ends or missing core operations.

    Maintenance

    ActivityMaintained
    ResponsivenessLimited data

    Related MCP Connectors