Skip to main content
Glama
README.md
# Larnitech MCP

<!-- mcp-name: io.github.mpopovych-thinkhome/larnitech-mcp -->

**Version 1.4.0 Beta** · [Changelog](CHANGELOG.md) · MIT licensed

An [MCP](https://modelcontextprotocol.io) server that lets an AI agent read
and control a [Larnitech](https://larnitech.com) smart-home installation over
the API2 protocol — lights, climate, blinds, sensors, meters.

It ships with a documented device-type reference built from live testing
against real controllers, so the agent looks up how a widget actually
behaves instead of guessing from key names. That matters more than it
sounds: on this platform writing `state: "closed"` to a gate is
acknowledged with `success: true` and then silently ignored, and several
climate types drop half of any two-key write. Those traps are documented,
checked before every write, and listed in this README's own safety section.

---

## What it does

**Reading** — open, no configuration beyond the API key.

| Tool | What it does |
|---|---|
| `list_objects` | configured controllers (never returns keys) |
| `check_connection` | connect, authorize, report device count |
| `list_devices` | full snapshot, filterable by area / type / name |
| `get_device` | status of one device by address |

Consecutive calls share one authorized connection: the socket stays open
for four minutes after a request, so a burst of reads costs one connect
instead of one per call. It is retired before the controller's own
five-minute idle timeout, and one the controller has already dropped is
replaced without the call failing.

**Understanding what came back** — statuses are type-specific and
occasionally not key/value at all.

| Tool | What it does |
|---|---|
| `get_docs()` | overview of every documented device type |
| `get_docs("AC")` | full detail for one type: status keys, enums, XML attributes, script byte layout, quirks |
| `get_docs("bugs")` | numbered registry of confirmed vendor bugs |
| `get_docs("protocol")` | API2 protocol reference |

Responses flag statuses that need care: an opaque `hex` blob, a
`malfunction` fault code in place of a normal reading, an all-`null`
payload from a meter that missed its poll cycle — which means *no data*,
not zeros — or a bare `state: "undefined"`, which is how a device that is
physically offline still answers.

**Watching** — non-blocking, for "press the switch and tell me what moved".

| Tool | What it does |
|---|---|
| `watch_start` | begin watching; returns immediately |
| `watch_read` | drain what changed since the last read, per key `from`/`to` |
| `watch_stop` / `watch_list` | stop one / list active |

A watch keeps its own connection alive, so it survives the controller's
5-minute idle timeout and can stay open across a long conversation.

**Writing** — off by default; one call, checked before and after.

| Tool | What it does |
|---|---|
| `set_device` | validate, write, wait for the device to settle, report what actually landed |
| `modbus_request` | one raw Modbus RTU/TCP exchange on a `com-port`: read (FC 03/04) or write (FC 06/16) registers |

**Learning** — findings survive the session.

| Tool | Writes to |
|---|---|
| `add_docs_note` | that device type's own doc file |
| `add_preference` | `preferences.md`, served with every `get_docs` |

**Saving data** — a snapshot is worth more than scrollback.

| Tool | What it does |
|---|---|
| `save_snapshot` | keep a slice of controller data as a file |
| `list_snapshots` | what has been saved, per controller |
| `read_snapshot` | read one back, to compare against now |

Files land in `data/<controller>/<date>_<time>_<comment>.txt`, one folder
per controller — or in a folder of your own, if that installation already
has a project directory holding its drawings, configs and controller
backups:

```bash
python -m larnitech_mcp data-dir "Home" "/projects/home/backups"
```

Snapshots then sit with the rest of that site's files instead of in a
separate store. `list_snapshots` finds both kinds.

Each is a JSON envelope — `object`, `saved_at`, `comment`
and the payload under `data` — so provenance travels with the file and
`read_snapshot` hands back parsed structure rather than text to re-parse.
Numbers stay numbers and `null` stays null, which matters here: telling
"no data" apart from zero is the difference between a quiet meter and a
reading of nothing.

Ask for "save the current state" and the agent files it there; ask "has
this changed since last week" and it has something to compare against.

**Reporting** — `report_bug` turns something you hit into a ready-to-file
issue for this repository. It composes the report, strips identifiers
(API keys, serials, hostnames, site names) and returns a prefilled link.
Nothing is posted: you open the link, read exactly what would be
published, and submit it yourself under your own account. No token is
needed by anyone.

---

## Requirements

- Python 3.11+
- A Larnitech controller you administer, reachable via the Larnitech cloud
  or on your LAN

## Install

```bash
pip install larnitech-mcp
```

A virtual environment is worth using, since you'll point Claude Code at
that interpreter's absolute path:

```bash
python -m venv ~/.venvs/larnitech
~/.venvs/larnitech/bin/pip install larnitech-mcp     # Windows: Scripts\pip.exe
```

Your API keys, preferences, saved snapshots, and any device notes the agent
records live in `~/.larnitech-mcp/`, outside the package, so upgrading never
touches them.

To work on the server itself, install from a clone instead:

```bash
git clone https://github.com/mpopovych-thinkhome/larnitech-mcp.git
cd larnitech-mcp
pip install -e .
```

## Where to get your API key

Both values come from **LT_Setup**, Larnitech's own configuration app, on
the installation you administer:

| What | Where in LT_Setup |
|---|---|
| API key | **Security → Show API key** |
| Serial number (cloud connection) | **General** |
| IP address (LAN connection) | **General**, or your router's DHCP table |
| WebSocket port (LAN, default `2041`) | **General → API → Websocket port** |

The key grants full read and write access to the installation. Treat it
like a password.

## Connect a controller

Register it, then store the key:

```bash
python -m larnitech_mcp add "Home" cloud --serial YOUR_SERIAL
python -m larnitech_mcp auth "Home"
```

`auth` prompts with hidden input and writes the key to
`~/.larnitech-mcp/project_keys.json`. The key never passes through the chat
transcript this way — prefer it over the `object_set_key` tool, which works
but leaves the key in the session log.

For a controller on your LAN instead of via the cloud:

```bash
python -m larnitech_mcp add "Home" local --host 192.168.1.50
```

Check it works:

```bash
python -m larnitech_mcp test "Home"      # connect, authorize, count devices
python -m larnitech_mcp devices "Home"   # full snapshot, counts per type
```

## Add to Claude Code

Add the server to the top-level `mcpServers` object in `~/.claude.json`,
using the absolute path to the venv's Python:

```json
{
  "mcpServers": {
    "larnitech": {
      "command": "/home/you/.venvs/larnitech/bin/python",
      "args": ["-m", "larnitech_mcp", "serve"]
    }
  }
}
```

On Windows the command is the `.exe`, with escaped backslashes:

```json
"command": "C:\\Users\\you\\.venvs\\larnitech\\Scripts\\python.exe"
```

It must be the top-level `mcpServers` key in `~/.claude.json` itself — a
`.mcp.json` placed inside the `~/.claude/` folder is never read. To scope
it to one project instead, put the same block in a `.mcp.json` at that
project's root. Restart Claude Code fully afterwards; closing the window
is not enough.

Other MCP clients work the same way — the server runs on stdio via
`python -m larnitech_mcp serve`.

---

## Safety model

**Reading is open. Writing is off until you turn it on, per controller,
from a terminal:**

```bash
python -m larnitech_mcp allow-write "Home" on
```

There is deliberately no tool for this — an agent cannot grant itself
write access, only tell you the command.

**Every write is checked before it is sent.** `set_device` validates the
payload against the documented vocabulary and ranges for that type — an
`on`/`off` key gets only `on`/`off`, an AC setpoint stays inside the range
the unit itself reports, a read-only sensor takes nothing — and rejects a
malformed or out-of-range command without touching the controller.

**And checked after it lands.** An ack only means the command was accepted;
some types ack a write and then ignore it. So `set_device` waits for the
device to go quiet and reads it back: `mismatched` lists requested keys that
did not take, `unrequested_changes` anything the controller altered on its
own.

**Writes can be sequences,** because some types cannot be driven with one
frame:

```json
[{"status": {"mode": "heat"}, "delay_after": 1.0},
 {"status": {"state": "on"}}]
```

Sending `mode` and `state` together loses the `state`: the controller
re-evaluates the channel after a mode change and overrides whatever
arrived behind it. The same applies to `vent` (`state` + `fan`) and to
clearing an `automation` before switching a channel off. `set_device`
rejects the combined forms and tells you the sequence to use instead.

**No key is ever returned by a tool,** and keys are masked out of error
messages.

## Device documentation

`larnitech_mcp/docs/device-types/` holds one file per device type plus an
index, covering the API2 status keys, XML attributes, script-side byte
layout, and every quirk confirmed by live testing. `bugs.md` alongside it is
a numbered registry of confirmed vendor bugs that the type files reference.
Read them through `get_docs` rather than by path — that also picks up
anything you've added locally.

Notes the agent records with `add_docs_note` go to `~/.larnitech-mcp/docs/`,
not into the installed package, so they survive upgrades. Your copy wins on
read; everything you haven't edited still comes from the shipped set.

This is a working knowledge base, not a spec: entries say plainly when
something is confirmed live, observed but unexplained, or still unknown.
Corrections and additions are welcome — that is the most valuable kind of
contribution here.

## Command reference

| Command | Effect |
|---|---|
| `add <name> cloud --serial S` | register a cloud controller |
| `add <name> local --host H [--port P]` | register a LAN controller |
| `auth <name>` | store its API key (hidden prompt) |
| `list` | configured controllers, key presence |
| `test <name>` | connect, authorize, count devices |
| `devices <name> [--full]` | full snapshot, decoded |
| `allow-write <name> on\|off` | enable or disable writes |
| `remove <name>` | drop a controller and its key |
| `serve` | run the MCP server on stdio |

## Status

Beta. Reading, watching, and writing all work and have been exercised
against live hardware, but this has been tested against a limited set of
installations. Device types documented as unconfirmed genuinely are —
see `get_docs` output and the per-type files.

### Modbus on a `com-port`

`modbus_request` sends one frame — slave, function 03/04/06/16, register,
count or values — onto the bus behind a `com-port` and returns the decoded
answer. Reads work on any object; writes need `allow_write`. Modbus TCP ports
take the same frame as RTU, CRC included (assumed; verified on RTU only).

The port may be in use by the controller's own scripts, so other requests
can be on the bus at the same time, and an answer can belong to someone
else's request rather than yours — observed live. One request is the
default; when a value really matters, send the same request twice about a
second apart and trust it only if both answers agree. A device that does not
answer within 2 s is reported as a timeout, never as the port's last known
frame. Details:
[com-port](larnitech_mcp/docs/device-types/com-port.md).

Not affiliated with or endorsed by Larnitech.

## License

[MIT](LICENSE)

## Contact

Mykhailo Popovych
- Telegram: [t.me/M_Popovych_ThinkHome](https://t.me/M_Popovych_ThinkHome)
- Phone (WhatsApp): +370 632 89 991, +380 99 333 99 96
- Email: [m.popovych@thinkhome.io](mailto:m.popovych@thinkhome.io)