Skip to main content
Glama

Drug interaction risk from in vitro data (ICH M12)

ind_ddi_risk
Read-onlyIdempotent

Evaluates per enzyme and transporter whether ICH M12 in vitro data exclude a clinical interaction for an investigational drug as perpetrator, returning cutoff checks, conclusions, and next steps.

Instructions

Decide, per enzyme and transporter, whether ICH M12 lets in vitro data exclude a clinical interaction with the investigational drug as precipitant.

Applies the basic methods (Cmax,u/Ki,u < 0.02; gut CYP3A (Dose/250 mL)/Ki,u < 10; TDI (kobs+kdeg)/kdeg < 1.25; mRNA ≥ 2-fold below 50×Cmax,u; transporter Table 1 cutoffs), then the basic kinetic induction model (R > 0.8) and the mechanistic static model (AUCR 0.80-1.25, inhibition and induction also evaluated alone) when data are given. Applies the fu,p 1% floor and the M12 default Fa, Fg, ka. Returns each check, a conclusion per target and the next step. Not for the drug as a victim, and not a PBPK model.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "perpetrator": "<perpetrator>"
    },
    "name": "ind_ddi_risk"
  }
}

Input Schema

NameRequiredDescriptionDefault
enzymesNoPer CYP/UGT: Ki,u; KI,u + kinact; induction donors or Emax/EC50; optional victim fm for the mechanistic static AUCR.
perpetratorYesThe investigational drug: steady-state Cmax at the highest dose, fu,p, dose, molecular weight, route.
transportersNoPer transporter: unbound IC50.

Output Schema

NameRequiredDescriptionDefault
checksYes
summaryYesOne or two sentence plain-language answer.
findingsNo
i_gut_uMYes[I]g = Fa·ka·Dose/Qen, µM (oral only).
citationsYes
cmax_u_uMYes
disclaimerNoDecision support only. Verify against the current guideline and your site SOPs.
provenanceYes
assumptionsNo
conclusionsYes
cmax_inlet_u_uMYes
dose_conc_gut_uMYesDose/250 mL in µM (oral only).

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A4.6/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations only declare it a safe, idempotent, closed-world read; the description adds substantial context beyond that by enumerating the exact cutoffs applied (Cmax,u/Ki,u < 0.02, gut CYP3A < 10, TDI < 1.25, R > 0.8, AUCR 0.80-1.25), the fu,p 1% floor and M12 default Fa/Fg/ka, and what is returned (each check, a per-target conclusion, next step). This lets an agent predict the output shape and the assumptions baked into the verdict.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Front-loaded with the decision statement, then a compact threshold list, then the model escalation rule and exclusions. Dense parenthetical threshold notation is efficient rather than padded, though the run-on sentence listing all cutoffs takes effort to parse.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a high-complexity regulatory calculation with nested objects and an output schema, the description covers decision scope, all applied defaults and floors, model escalation logic, and explicit out-of-scope cases. An agent has everything needed to decide to call it and to interpret assumptions without reading the schema internals.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100% with rich nested descriptions, so the baseline would be 3, but the description adds interpretive meaning by tying specific parameters to model behavior - the fu,p 1% floor, the M12 default Fa/Fg/ka, and the fact that the mechanistic static AUCR only runs when victim fm data are supplied. It does not, however, explain the enzyme/transporter entry semantics beyond what the schema already states.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific decision verb ('Decide, per enzyme and transporter'), the exact regulatory question (does ICH M12 allow in vitro data to exclude a clinical interaction), and the role of the drug (as precipitant). This is unmistakably distinct from sibling risk tools such as ind_first_in_human_dose or ind_metabolite_coverage.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Gives clear triggering conditions ('when data are given' for the kinetic induction and mechanistic static models) and explicit exclusions ('Not for the drug as a victim, and not a PBPK model'). It does not name a sibling tool as the alternative, so the agent must infer where to route victim-side or PBPK questions.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.