Skip to main content
Glama

Related Servers

Alternatives to tuya-local-mcp

No user-submitted related servers found.

    Related Servers

    • A
      license
      A
      quality
      B
      maintenance
      Enables Claude to control Philips Hue lights through a Hue Bridge on the local network, handling plain-language requests for on/off, brightness, color, scenes, looping effects, and whole-room power budgets. Fades and timers run on the bridge itself, and no Hue cloud account is required.
      9
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables an MCP-compatible AI client to locally control a compatible Tuya / Smart Life Wi-Fi bulb over the LAN, including status checks, power, color, brightness, and color temperature, without Tuya Cloud calls at runtime.
      4
      MIT
    • A
      license
      A
      quality
      C
      maintenance
      Enables local network control of Tuya and Smart Life smart home devices without cloud round-trips, including power, brightness, color, and raw datapoint operations.
      9
      MIT
    • F
      license
      Not graded
      quality
      D
      maintenance
      Enables Claude Desktop to control Lutron Caseta smart lighting systems locally, including turning lights on/off, setting dimmer levels, and activating scenes.
      -

    TDQS

    B3.4/5.0

    Scored across 10 tools

    Disambiguation4/5

    Most tools map to a distinct action-resource pair (power vs. set vs. status), and descriptions clarify the split between list_lights (configuration metadata) and light_status (runtime state). The one soft overlap is set_light vs. power_light, since scene presets can contain on/off values, and list_lights vs. scan_lan_ips both touch light IPs — but descriptions steer the agent adequately.

    Naming Consistency4/5

    Nearly everything follows verb_noun (list_lights, set_light, get_presets, upsert_preset, delete_preset, list_timers, cancel_timer, scan_lan_ips). light_status breaks the pattern as a noun_noun state read, and the plural/singular resource naming (lights vs. light) is slightly uneven, but overall the convention is predictable.

    Tool Count5/5

    Ten tools is well within the ideal band and each earns its place: light discovery/listing, status, power, setting, preset CRUD, and timer list/cancel. Nothing feels padded or redundant.

    Completeness3/5

    Presets have full CRUD and timers have list/cancel plus an inline delay parameter, covering the main control loop. However, there is no way to add/register a new light or edit its name, zone, or target words — scan_lan_ips only refreshes IPs — and timers cannot be created or inspected as a first-class operation, leaving a notable configuration gap.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues