Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault
FASTMEAN_APP_DIRNoПапка отдельно установленной FASTMEAN с Fastmean.exe
FASTMEAN_OUTPUT_DIRNoПапка новых схем и результатов, вне установки приложения

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": false
}
prompts
{
  "listChanged": false
}
resources
{
  "subscribe": false,
  "listChanged": false
}

Tools

Functions exposed to the LLM to take actions

NameDescription
fastmean_statusA

Check installation, native engines, output location and supported operations.

fastmean_exampleA

Get an editable JSON spec: rc_lowpass, rlc_lowpass, voltage_divider, flyback.

components have kind, name, nodes [positive,negative] for U/V, and SI value. Voltage waveform: {kind:dc|sine|pulse, frequency, amplitude, phase, delay, high, low, duty_percent, rise_time}; only fields applicable to its kind. flyback uses a native TR transformer, separate magnetizing L, native SW voltage-controlled switch, pulse drive and diode rectifier. Use transient.

fastmean_create_circuitA

Create a native .scm in a fresh folder from a node-based JSON circuit spec.

Start from fastmean_example. R/C/L values must be positive. Ground is 0. Components connect through physical wires and junctions; ports are external I/O only. Optional spec.layout.placements maps names to {x,y,rotation}; x/y are multiples of 4 and rotation is 0=left/right,1=up/down,2/3=reversed. spec.layout.density is compact (default) or standard. Explicit coordinates stay unchanged; density controls automatic spacing only. ground_style is rail (default) or local. U nodes are [+,-]; I nodes are [from,to]. A single-terminal node gets one short wire and native CON endpoint, without an added electrical load or external PORT. All names used in analysis must be ASCII. Does not open a window. Fixed native primitives: D nodes=[anode,cathode], parameters={Ron,Roff,Uon}; G/VCCS, E/VCVS and F/CCCS use four native-ordered nodes and a numeric value. TR/TRANSFORMER nodes=[p1,p2,s1,s2], dotted pins1/3, n=Np/Ns>0; value=n or parameters={n}. SW/VCSWITCH nodes=[control+,control-,switch1,switch2], parameters={Ron,Roff,Uon,Uoff}, 0<Ron<=Roff, Uoff<=Uon; native hysteresis. See example(kind='flyback') and the guide for polarity and magnetic storage. spec.analysis.transient accepts stop, step and eps (0<eps<=0.1), saved in SCM. Use fastmean_create_project for X subcircuits and portable model files. All44 insertable classes are supported: call fastmean_catalog(detail=true) for nonlinear R/C/L, H, GYR, TR3, TUBE, NMOS_SMALL, NPN, OPAMP_SAT, PWM, PAM1/PAM2, BALMOD, THYRISTOR, MOSFET, LINE, BRIDGE, RS/DFF/JK/RSCLK, NOT/AND/OR/XOR/LATCH/COMP and SUM. Supply parameters by native key; omitted values use explicit adapter templates. Sources also support triangle/PWL.

fastmean_create_projectA

Create a portable native root circuit and fixed numeric subcircuit files.

spec={name?,models:{MODEL:{pins:{Left:[B],Top:[C],Right:[],Bottom:[E]}, circuit:{components:[...],ports:{B:b,C:c,E:e}}}},circuit:rootCircuit}. X components use {kind:X,name:Q1,model:MODEL,connections:{B:base,C:col,E:0}}. Side lists determine native terminal numbering Left,Top,Right,Bottom. A definition may float; ports must match declared pins exactly. All models must exist and be acyclic; instance parameters and .parameter headers are unsupported. Other components use the create_circuit schema. Each circuit supports compact/standard density and explicit coordinates independently. Return main.scm, models/*.scm, original JSON specs, hashes and a manifest. To edit definitions, modify the saved project.spec.json and call this tool again: every call creates a new project and preserves the previous files. Does not launch FASTMEAN, calculations, GUI or desktop automation.

fastmean_inspectA

Read SCM metadata, root parameters, ports and formulas without losing fields.

Default summary has compact components and independently budgeted pages; include_objects adds a raw-object page. section selects complete native data with offset/limit pagination. data is a list, mapping or text, as page.kind reports. Use detail_path for nested large fields, e.g. objects [5,"Params"] or analysis ["TD","Expressions"]. Text selections paginate characters. Reuse source_sha256 as expected_source_sha256 on later pages to reject edits between reads. Reads create no jobs and start no calculations or windows.

fastmean_edit_parametersA

Update existing numeric root .parameter/.param constants in a new copy.

updates maps exact case-sensitive parameter names to finite numbers/SI values. Only literal spans change; descriptions, component bindings, graph formulas and portable model files are preserved. Expressions, ambiguous declarations and overriding define/global/set names are rejected. Use inspect's root_parameters before editing. This does not run a calculation or a GUI. Pass the inspection's source_sha256 as expected_source_sha256 to reject source changes made between inspection and this request.

fastmean_annotate_circuitA

Add numeric constants, text explanations and saved native formulas to a copy.

parameters maps ASCII identifiers to finite numbers/SI literals. bindings maps root component names to an expression for convenience value fields, or to native scalar fields, e.g. {"TR1":{"n":"Ratio"},"VIN":{"PULSE.F":"Freq"}}. Native child-instance parameter declarations are unsupported. descriptions adds plain explanatory native TEXT objects. [] clears saved traces; None preserves them. td_signals/fd_signals replace saved active expressions, for example U(OUT), I(RL), db(U(OUT)/U(IN)), phs(U(OUT)/U(IN)). Root TD/FD settings are retained, requested expressions are preloaded, and SCM model dependencies are privately packaged. Sources remain unchanged. Does not launch calculations, a window or desktop automation.

fastmean_edit_valuesA

Create an edited copy, retaining topology and unknown native objects.

updates maps component names to SI values, or to {value:...,waveform:...}. This supports R/C/L/U/I value edits and never overwrites the selected source. A literal edit replaces any parameter binding on that component. To keep shared .parameter bindings, use fastmean_edit_parameters instead. Explicit waveform fields update the selected mode, retaining omitted fields and other modes; waveform amplitude/high overrides value when supplied.

fastmean_export_netlistA

Export the installed FASTMEAN engine's native expanded circuit netlist.

Opens a sanitized recursive working copy in a private batch process, runs save_netlist and exits. Returns bounded text, full netlist and provenance artifacts. Does not launch a GUI or request AC/transient simulation. timeout limits only this owned worker to 1–60 seconds; cancellation uses the same owned-process mechanism as other native operations.

fastmean_acB

Run native AC analysis. Return CSV, native text, manifest and a PNG chart.

Example signals: db(U(out)/U(in)), phs(U(out)/U(in)), mag(U(out)), I(R1). Use exact circuit port/component names. PNG is rendered from native data. A working copy disables graph windows and sweeps; original SCM is untouched.

fastmean_transientB

Run native time-domain analysis; return native samples, CSV and PNG.

Examples: U(out), U(in), I(R1). Seconds and SI values are numeric. Starts at time zero with the schematic's component IC values; no saved-state files. timeout limits this owned worker to 1–60 seconds (default 60).

fastmean_catalogB

Discover native FASTMEAN element kinds, aliases, pins and parameter schemas.

Start here before creating an unfamiliar component. detail=true includes native defaults, bounds and validation schemas. Numerical test evidence is reported separately from the observed native factory and pin geometry.

fastmean_edit_propertiesA

Edit native component parameters, tables and saved settings in a new project.

updates={"TR1":{"n":2},"SW1":{"Ron":0.01}}; nested parameter patches retain omitted fields. analysis selects saved TD/FD/AOD/SOD/DCOP fields, including graph expressions and sweep settings. definitions saves native .define variables/functions as TEXT. No source files are overwritten or run here. File/model interfaces use create_project, not arbitrary parameter paths.

fastmean_dcB

Calculate the native DC operating point in a private copy.

Uses native DC initialization and a zero-duration native export. DC source ramps/delays are removed only in the private DC copy and recorded. Supply source_values to replace non-DC source waveforms for this calculation.

fastmean_sweepA

Sweep one native variable or component.parameter over 1–32 values.

Each point is a separate owned native calculation. settings carries the corresponding AC/transient/DC options; native samples and provenance are retained for every point. The original schematic is preserved.

fastmean_spectrumC

Return spectrum amplitude/phase/PSD of real FASTMEAN transient samples.

FASTMEAN calculates time samples. NumPy interpolates onto a uniform grid and performs rFFT; the PNG is Matplotlib, not a native FFT-window screenshot. Native source CSV, selected window and transform normalization are retained.

fastmean_evaluateB

Evaluate native post-analysis functions or the native FASTMEAN FFT.

signals may use last/AVG/RMS or native harmonic functions. FFT mode uses explicit fft settings and FFT expressions; a separate native time writer proves the simulated interval. Returns the actual native summary/FFT table, not a fabricated transient time axis. No arbitrary script is accepted.

fastmean_harmonicsB

Extract up to seven harmonics using native tre/tim/tmag/tph expressions.

Frequencies are Hz; window=[start,end] seconds. FASTMEAN itself evaluates the harmonic expressions. This differs from the NumPy spectrum tool.

fastmean_symbolicA

Get native CIRSYM U/I/H/Z/Y formulas for supported linear zero-state circuits.

Native FASTMEAN exports connectivity before conversion to CIRSYM. Optional input must be driven by a unique grounded independent voltage source; the transfer function is derived by dividing the native output by its amplitude. Set input=null for an output equation only. Not an arbitrary equation solver.

fastmean_list_examplesA

Find installed example SCM files by substring; use returned paths in analysis.

fastmean_openA

Open a working copy through the installed FASTMEAN executable's documented CLI.

Recursively packages SCM model dependencies and records source/copy hashes. Starts a separate application process; leaves existing windows alone. The circuit window stays open for the user, and is not controlled automatically. This command does not apply locale emulation; old Russian UI text may appear garbled on Windows configured for another legacy code page.

fastmean_search_manualC

Search the verified native automation reference; query is literal text.

fastmean_relayoutA

Rebuild a supported circuit as adjacent components with physical wires.

Converts old per-pin PORT layouts into a connected orthogonal drawing. Preserves values, waveforms and native analysis in a new SCM. Supports catalog primitives and portable subcircuits. Optional placements: {R1:{x:960,y:1000,rotation:0}}. Numeric node-voltage references require stable named ports before changing geometry. density selects compact (default) or the previous standard spacing.

fastmean_previewA

Render a wire-connected SCM to readable PNG and SVG for visual review.

This is an MCP rendering of native objects, not a FASTMEAN screenshot. Proven native L/midpoint bends are reconstructed exactly. Unsupported symbols/detours are rejected. No application window is opened. include_text=False omits TEXT notes from this image and its bounds only; all source annotations and parameter bindings remain unchanged.

fastmean_list_runsC

Find persisted calculations, created diagrams and preview runs after restart.

fastmean_get_resultC

Reopen a persisted result with images and registered artifact resources.

fastmean_plotA

Plot registered AC, transient, native FFT or NumPy spectrum data through MCP.

panels selects 1–12 exact exported columns. A panel is {signal, label?, unit?, scale?:1, metrics?:[rms], guides?:[], color?:'#2563eb'}. Metrics are rms/mean/peak/min/max/peak_to_peak; guides are mean/rms and include that measurement. Frequency panels have metrics=[]; time-weighted metrics require TD. unit is a caller-supplied display label; display_value=native_value*scale with finite positive scale. No new formulas are evaluated. For native power, export e.g. U(OUT)*I(RL) during transient and select that exact column here. Windows are [start,stop] in original seconds/Hz, independently of x_unit. Interpolate exact endpoints, retain adaptive timestamps and both states of equal-time switching events in native order, and reject extrapolation. RMS uses trapezoids of squared samples. Metrics use the full measurement window before graphical decimation. Original run stays intact; a new run returns ImageContent, PNG/SVG/spec/measurements/manifest resources.

fastmean_read_dataC

Read a page of registered calculation samples with their recorded provenance.

fastmean_cancelB

Cancel one active native operation listed by status; never other processes.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription
guideVerified native FASTMEAN automation, circuit spec and limits

TDQS

B3.2/5.0

Scored across 29 tools

Disambiguation3/5

Most tools target distinct actions, but there are two large clusters with fuzzy boundaries: the editing tools (edit_parameters, edit_values, edit_properties, annotate_circuit, relayout) all create modified copies, and the analysis tools (ac, transient, dc, sweep, spectrum, evaluate, harmonics) overlap enough that an agent must read long descriptions to pick correctly. The descriptions do explicitly disambiguate (e.g. NumPy spectrum vs native harmonics vs native FFT evaluate), which prevents a lower score, but the create_circuit vs create_project split is also easy to confuse.

Naming Consistency4/5

All names share a consistent fastmean_ snake_case prefix and split cleanly into action tools (create_*, edit_*, list_*, get_*, search_*, export_*, read_*) and analysis tools named by the analysis type (ac, transient, dc, sweep, spectrum, harmonics, symbolic). The mix of bare nouns for analyses and verb_noun elsewhere is a minor deviation but is coherent and readable.

Tool Count2/5

At 29 tools this is well above what an agent can hold comfortably, and several tools could be merged (the four separate edit tools, the seven-plus analysis entry points). The domain is genuinely broad, but the surface is heavier than necessary for the workflows it supports.

Completeness4/5

The lifecycle is well covered: authoring (create_circuit, create_project, catalog, examples, manual), inspection, multiple edit paths, all major native analyses, plotting/spectrum post-processing, persistence (list_runs, get_result), export and cancel. Gaps are minor — no tool to delete/clean up persisted runs or projects, and no explicit close/reset for opened windows.

Maintenance

ActivityNo data
ResponsivenessOutdated data