Skip to main content
Glama

statyba_energy_certificates

Read-onlyIdempotent

Look up Lithuanian building energy performance certificates by certificate number or address. Get energy class, heated area, heat sources, and validity dates from official open data.

Instructions

Lithuanian buildings' energy performance certificates (pastatų energinio naudingumo sertifikatai, Statybos sektoriaus vystymo agentūra's open data), by certificate_number or by address with place: at an address, the building's own and its flats' (3-44 is flat 44 of number 3). The open data holds no unique nor cadastral number for them. The answer is Markdown: a heading naming what was searched and how many were found, one table of up to 100, newest first (the heading says "there are more" where there were), and the source on the last line. Each: number, energy class (A++ to G), purpose code and group (GYV residential, VIES public, PRAM industrial) as the certificate writes them, address, whether it is a typical flat certificate, heated area in m², the energy it counts for heating and CO2 as the certificate gives them (the open data names no unit; — for a typical flat certificate, which carries none), heat sources, issue and expiry dates, and the register's note, such as one replaced by a newer. The expert who issued it is left out. Where the open data holds none, the answer is one sentence saying so.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "statyba_energy_certificates"
  }
}

Input Schema

NameRequiredDescriptionDefault
placeNoThe town, village or municipality the address is in, in any case form, such as "Varėna", "Kaunas" or "Vilniaus r.". Each word is matched by its stem, so the answer can hold a like-named place: check each address.
addressNoThe street and house number as the address register writes them, abbreviations and capitals included, such as "Šilo g. 39", "Gedimino pr. 9" or a flat's "Ateities tak. 3-44"; a village house without a street is its village and number, such as "Rukaičiai 4". Goes with place.
certificate_numberNoA certificate's number, such as PR-0309-03790.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A4.1/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Beyond the annotations, the description discloses substantial behavior: results are Markdown with a heading and table of up to 100 newest-first records, a 'there are more' signal, source attribution, and a one-sentence answer when no data exists. It also explains data limitations, including missing unique/cadastral numbers, unitless heating/CO2 values, omitted expert issuer, and special handling for typical flat certificates.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is front-loaded with the resource and search modes, then moves into output structure and field details. It is dense but largely purposeful, since no output schema exists; however, the single long paragraph is harder to scan than it could be.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With no output schema, the description carries the full return contract and does so thoroughly: it describes the Markdown shape, table cap, ordering, fields, caveats, omissions, and no-result behavior. That is complete enough for an agent to invoke and interpret the tool correctly.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so the parameters are already well documented. The description adds the alternative search-mode framing and the flat-number interpretation, but most parameter meaning is already present in the schema, so this remains at the baseline level.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description states a specific resource and retrieval modes: Lithuanian buildings' energy performance certificates, searchable by certificate_number or by address with place. It is clear what the tool returns and what it does not include, but it does not explicitly distinguish itself from sibling tools such as statyba_building_condition or statyba_documents.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

It clearly explains the two usage paths: certificate_number alone, or address together with place. It also warns that place matching is stem-based and can return like-named places. However, it gives no explicit when-not-to-use guidance or comparison to sibling tools.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.