rigol-mcp
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
| RIGOL_HOST | Yes | Scope IP address or host name. | |
| RIGOL_PORT | No | Scope SCPI port. | 5555 |
| RIGOL_TIMEOUT | No | Seconds to wait for the scope. | 10 |
| RIGOL_DATA_DIR | No | Where captures are saved. In Docker the default is /data. | ~/.local/share/rigol-mcp |
| RIGOL_HOST_PORT | No | Docker only: port published on the host. | 8790 |
| RIGOL_HTTP_HOST | No | HTTP bind address, or use --bind. | 0.0.0.0 |
| RIGOL_HTTP_PORT | No | HTTP port, or use --port. | 8790 |
| RIGOL_MCP_TOKEN | No | Token clients must send. Required for HTTP mode. | |
| RIGOL_READ_ONLY | No | Set to 1 to block scope_write. | off |
| RIGOL_TRANSPORT | No | Transport mode; http is the same as --http. | stdio |
| RIGOL_PUBLIC_URL | No | Base URL used in links to screenshots and the gallery. | |
| RIGOL_ALLOW_NO_AUTH | No | Set to 1 to allow HTTP without a token on trusted networks only. | off |
| RIGOL_KEEP_WAVEFORMS | No | Number of waveform CSVs to keep; 0 keeps all. | 100 |
| RIGOL_KEEP_SCREENSHOTS | No | Number of screenshots to keep; 0 keeps all. | 100 |
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
Controls a Rigol DS1000Z oscilloscope. Start with scope_status. Settings are only changed with scope_write, and only when the user asks: real circuits may be connected. Measurements that are null are invalid on the scope (e.g. frequency of a DC signal).
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {
"listChanged": false
} |
| prompts | {
"listChanged": false
} |
| resources | {
"subscribe": false,
"listChanged": false
} |
| experimental | {} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| scope_statusA | Overview of the scope: model, trigger, timebase, sample rate, and for each channel whether it is on, its V/div, offset, coupling, probe ratio, plus Vpp, Vavg, Vrms and frequency. Invalid measurements are null. Start here. |
| scope_measureA | Run the scope's built-in measurements on one channel (1-4). items: any of VMAX VMIN VPP VTOP VBASE VAMP VAVG VRMS OVER PRES MAR MPAR PER FREQ RTIM FTIM PWID NWID PDUT NDUT. Default: a common set. Times are in seconds, duty cycles are fractions (0.25 = 25%). Invalid results are null. |
| scope_waveformA | Download the on-screen waveform of one channel (1200 samples) and return summary stats plus up to max_points evenly spaced [time_s, volts] samples (0 = stats only, 1200 = every sample). include_csv=True also returns every sample as CSV text (~30 KB). Each download is saved with a timestamp; see scope_waveform_history. |
| scope_screenshotA | Capture the scope's display as a PNG. Every screenshot is saved with a UTC timestamp (the last RIGOL_KEEP_SCREENSHOTS are kept); see scope_screenshot_history. |
| scope_screenshot_historyA | List saved screenshots, newest first (id, UTC timestamp, size, and URL when served over HTTP). Does not touch the scope. Use scope_screenshot_get to view one. |
| scope_screenshot_getA | Return a saved screenshot without touching the scope. id is 'latest' (default) or an id from scope_screenshot_history. |
| scope_waveform_historyB | List saved waveform CSVs, newest first, with channel and UTC timestamp. |
| scope_queryA | Send a read-only SCPI query (must end with '?') and return the reply, e.g. ':CHAN1:BWL?', ':ACQ:MDEP?', ':TRIG:EDG:SLOP?'. |
| scope_writeA | Change a scope setting with a SCPI command, e.g. ':CHAN1:SCAL 1', ':TIM:SCAL 0.001', ':RUN', ':STOP', ':SING', ':AUT'. ONLY use when the user asked to change the scope: real circuits may be connected. Returns the scope's error queue ('0,"No error"'). |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 9 tools
Status, measure, waveform, screenshot, and the history tools each have a clearly distinct target. The main soft overlap is that scope_query and scope_write are generic SCPI escape hatches that could in principle replicate status/measure/screenshot, but the descriptions scope them narrowly (read-only '?' / user-requested writes) so misselection risk is low.
All names share the scope_ prefix in consistent snake_case, which is highly predictable. There is a minor deviation in shape: some are noun-only (scope_waveform, scope_screenshot) while others are noun_verb (scope_status, scope_screenshot_get, scope_screenshot_history), but the pattern remains readable.
Nine tools is well within the sweet spot and each earns its place: a read/measure/capture core plus paired raw SCPI access and history retrieval. Nothing feels redundant or padded.
Core acquisition workflows (status, measure, waveform, screenshot, raw query/write) are covered, but the history surface is asymmetric: saved screenshots can be listed and fetched (scope_screenshot_history/get), yet saved waveform CSVs can only be listed with no tool to retrieve one. There is also no cleanup/delete operation and no dedicated trigger or channel-config helper, forcing agents into raw SCPI for common setup tasks.