Skip to main content
Glama
REW MCP Server

REW MCP Server

by koltyj

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault

No arguments

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": true
}
logging
{}
prompts
{
  "listChanged": true
}
resources
{
  "subscribe": true,
  "listChanged": true
}

Tools

Functions exposed to the LLM to take actions

NameDescription
rew_ingest_measurementC

Parse and store a REW measurement export for analysis. Accepts frequency response or impulse response data in REW text export format.

rew_compare_measurementsB

Compare two or more REW measurements to determine what improved, worsened, or stayed the same. Supports pre/post GLM comparison, placement comparisons, and L/R symmetry analysis.

rew_analyze_room_modesB

Analyze a measurement for room modes, peaks, and nulls. Optionally correlates detected issues with theoretical room modes based on room dimensions.

rew_analyze_decayB

Analyze decay characteristics from impulse response data to identify frequencies with excessive ringing or resonance. Implements ISO 3382 compliant T20/T30/EDT calculations.

rew_analyze_impulseC

Analyze impulse response data to detect early reflections, estimate reflection paths, and assess their impact on sound quality.

rew_interpret_with_glm_contextC

Interpret measurement analysis results considering Genelec GLM's capabilities and limitations. Explains what GLM can address, what requires physical solutions, and provides calibration-aware recommendations.

rew_average_measurementsA

Create a spatial average from multiple measurement positions. Implements REW's averaging methods: RMS (incoherent, recommended for spatial averaging), Vector (coherent, requires phase data), or hybrid methods. Useful for multi-position room calibration.

rew_analyze_roomA

Comprehensive room analysis combining peaks/nulls, room modes, sub integration, and L/R symmetry. Returns top 5 prioritized recommendations based on fixability-first scoring (60% fixability + 40% severity). Automatically handles missing optional inputs.

rew_api_connectA

Connect to a running REW instance's REST API. REW must be launched with -api flag or have API enabled in preferences. Default port is 4735.

rew_api_list_measurementsA

List all measurements available in the connected REW instance. Requires prior connection via rew_api_connect.

rew_api_get_measurementA

Fetch a measurement directly from REW via API. Use UUID (not index) to identify measurements, as indices shift when measurements are added/removed.

rew_compare_to_targetB

Compare a measurement against a target response curve. Supports flat, REW room curve (LF rise + HF fall), Harman curve, or custom curves. Provides deviation statistics and recommendations.

rew_api_measureB

Control REW measurements via API. Actions: status (get config), sweep (trigger measurement), spl (SPL measurement), cancel, configure. Note: Automated sweep measurements require REW Pro license.

rew_api_audioB

Configure REW audio devices via API. Actions: status, list_devices, set_input, set_output, set_sample_rate. Use to select measurement mic and output device.

rew_api_generatorC

Control REW signal generator via API. Generate test tones, pink noise, sweeps. Actions: status, start, stop, set_signal, set_level, set_frequency, list_signals.

rew_api_spl_meterB

Control REW SPL meter via API for live level monitoring. Supports A/C/Z weighting, Slow/Fast/Impulse response. Actions: start, stop, read, configure.

rew_api_measure_workflowB

Complete measurement workflow orchestration. Actions: setup (auto-configure devices), check_levels (verify signal chain), calibrate_level (target SPL), measure (single sweep), measure_sequence (L/R or multi-position). Handles device selection, blocking mode, and result retrieval automatically. Note: Sweep measurements require REW Pro license.

rew_api_calibrate_splA

Semi-automated monitor level calibration workflow. Actions: start (play pink noise + start SPL meter), check (read current SPL + get adjustment guidance), stop (end calibration). Guides user to target SPL (default: 85 dB broadcast reference) with configurable tolerance.

rew_api_check_levelsA

Check input levels for mic gain calibration. Reads RMS/peak dBFS and provides zone-based feedback (Clipping, Hot, Optimal, Low, Very Low) with adjustment guidance. Blocks measurement for clipping or very low conditions.

rew_api_measurement_sessionB

Guided L/R/Sub measurement workflow with session state. Actions: start_session (create new), measure (trigger measurement), get_status (check progress), stop_session (end). Sessions persist across tool calls and can be resumed. REW Pro license required for automated measurements.

rew_optimize_roomA

Get placement recommendations, validate adjustments, and track optimization progress. Actions: get_recommendation (next issue to fix), validate_adjustment (check if change helped), check_progress (overall status toward +-3dB target). One recommendation at a time for scientific approach.

rew_api_measurement_commandsC

Execute per-measurement commands via API. Actions: list_commands (get available commands for a measurement), execute (run a command on a measurement).

rew_api_measurement_eqC

Manage per-measurement EQ settings via API. Actions: get_equaliser, set_equaliser, get_filters, set_filters, get_target, set_target, predicted_response, filter_response, match_target.

rew_api_importC

Import measurement data into REW via API. Actions: frequency_response_file, frequency_response_data, impulse_response_file, impulse_response_data, rta_file, sweep_recording.

rew_api_eqC

Manage global EQ defaults and settings via API. Actions: list_equalisers, list_manufacturers, get_defaults, set_defaults, get_house_curve, set_house_curve.

rew_api_groupsC

Manage measurement groups via API. Actions: list, create, get, update, delete, list_measurements, add_measurement, remove_measurement.

rew_api_rtaC

Control REW Real-Time Analyzer via API. Actions: start, stop, capture, reset, configure, read_levels, read_captured, read_distortion.

Prompts

Interactive templates invoked by user choice

NameDescription
rew_calibration_fullComplete studio calibration: gain staging, L/R/Sub measurement, room analysis, optimization guidance
rew_gain_stagingCalibrate monitor levels to target SPL using pink noise and SPL meter
rew_measurement_workflowGuided L/R/Sub measurement with session state tracking
rew_optimization_workflowIterative placement optimization with measurement validation

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3.1/5.0

Scored across 27 tools

Disambiguation3/5

There are clear overlaps: rew_api_measure, rew_api_measure_workflow, and rew_api_measurement_session all trigger measurements, and rew_api_calibrate_spl, rew_api_check_levels, and measure_workflow's check_levels/calibrate_level actions overlap on signal-chain checking. Analysis tools (rew_analyze_room vs rew_analyze_room_modes) and EQ tools (rew_api_eq vs rew_api_measurement_eq) partially overlap, though descriptions mostly clarify. An agent can usually pick correctly but faces real selection ambiguity.

Naming Consistency4/5

All names use consistent snake_case with a rew_ prefix, and API-control tools follow a predictable rew_api_<domain> pattern. The analysis tools (rew_analyze_*, rew_compare_*, rew_ingest_*, rew_optimize_*) form a separate but internally consistent family. Minor deviations (noun-phrase tools like rew_api_measurement_session vs verb-led tools) keep it from a perfect 5.

Tool Count2/5

At 27 tools the surface exceeds the 25-tool threshold flagged by the rubric for the purpose, and several tools (multiple measurement-triggering paths, redundant level-check tools) add bulk rather than distinct value. The REW domain is genuinely large, but the set could be consolidated without losing capability.

Completeness5/5

Coverage is extensive: connection, measurement listing/get, measurement triggering, import, averaging, room-mode/decay/impulse analysis, target comparison, global and per-measurement EQ, RTA, generator, audio device config, SPL metering, groups, and optimization guidance. Nearly every lifecycle step of the REW workflow is represented with no obvious dead ends.

Maintenance

ActivityInactive
ResponsivenessLimited data