CODESYS MCP Toolkit
README.md
<div align="center">
# CODESYS MCP Toolkit
**Let Claude, or any MCP client, read, write, compile and simulate Structured Text in your CODESYS V3.5 projects.**
English | [简体中文](README.zh-CN.md)
[](LICENSE)
[](https://www.npmjs.com/package/@codesys/mcp-toolkit)



[](https://modelcontextprotocol.io)
</div>
An [MCP](https://modelcontextprotocol.io) server that keeps one CODESYS session
open in the background and gives Claude, or any MCP client, direct access to
it. Claude works on your real project with the real CODESYS compiler, and you
can watch the code change as it happens.

## Highlights
- **Edits your real project.** POUs, methods, properties, interfaces, DUTs and
GVLs, as Structured Text.
- **Compiles with the real compiler.** Errors come back with object, line and
code, including in code that no task calls yet.
- **Tests in simulation.** Run, step exact cycles, read, write and force values
in CODESYS's own simulation, with nothing else to install.
- **Understands the project.** Outlines, I/O lists, the device tree and library
interfaces, without reading every object.
- **Shows its work.** A live panel with the project tree, the code as it is
written, compile results, and Accept or Revert for each change.
- **Designs operator screens.** Claude builds a live HMI for your program:
an overview of the line's stations, process diagrams with ISO 10628-2
symbols and ISA-5.1 instruments, clear state signs, values, trends and
alarms. It looks at the result and polishes it. You operate it in the
browser against the simulation, it exports as a native CODESYS
visualization with real CODESYS alarms, and as a P&ID sheet for the
documentation.
- **Ready for handover.** A project report with a commissioning checklist
built from the project, and a plain-text export of every object for git.
- **Never touches a real controller.** The only online connection is to
CODESYS's own simulation, and every online call checks for it first.
## Quick start
### Requirements
- Windows with **CODESYS V3.5** and its **Scripting** add-on. Tested with SP21
and SP22 on Scripting 4.2, and SP21 on 4.1. SP16 and later should work.
- **Node.js 20** or later.
Schneider EcoStruxure Machine Expert V2.3 (`LogicBuilder.exe`, Scripting 4.1)
works too: pass `--codesys-path` and leave out `--codesys-profile`, since Machine
Expert has no profiles. See the [Machine Expert notes](docs/machine-expert-testing.md).
### Install
```bash
npm install -g @codesys/mcp-toolkit
```
Coming from version 1? The tools have changed: see
[Migrating from v1](#migrating-from-v1).
### Connect it to Claude Desktop
Add the server to `%APPDATA%\Claude\claude_desktop_config.json`, then restart
Claude Desktop:
```json
{
"mcpServers": {
"codesys": {
"command": "codesys-mcp-tool",
"args": [
"--codesys-path", "C:\\Program Files\\CODESYS 3.5.21.0\\CODESYS\\Common\\CODESYS.exe",
"--codesys-profile", "CODESYS V3.5 SP21",
"--workspace", "C:\\PLC\\Projects"
]
}
}
}
```
`--codesys-path` and `--codesys-profile` are optional. Without them the server
uses the newest CODESYS install under Program Files and its newest profile.
Using OpenCode, Cursor, Cline or another client, or a model such as DeepSeek or
Qwen? See [Other clients and models](#other-clients-and-models).
### Try it
> Create a project called `BlinkDemo.project`. Add a function block that toggles
> an output once per second, call it from `PLC_PRG`, compile it, and prove in
> simulation that the output toggles.
CODESYS starts in the background when the server launches. A cold start takes
1 to 3 minutes; later starts take about 10 seconds.
Claude Desktop asks for approval per tool. Choose **Always allow** the first
time it asks about `codesys`, and once more for `open_sim_panel`. After that it
doesn't ask again.
## What Claude can do
Everything goes through one MCP tool, `codesys`, with an action for each
operation. [The reference](docs/reference.md) describes each one.
| Area | Actions |
| --- | --- |
| **Projects** | `open_project` `create_project` `save_project` `close_project` `codesys_status` |
| **Read code** | `get_project_tree` `read_objects` `search_code` `get_outline` |
| **Change code** | `write_object` `create_object` `create_graphical` `delete_object` `rename_object` |
| **Build** | `compile` |
| **Libraries** | `find_library` `list_libraries` `add_library` `pin_library` `remove_library` `get_library_api` `get_signature` |
| **Navigate code** | `find_references` `rename_symbol` |
| **Tasks and I/O** | `list_tasks` `configure_task` `get_io_list` `get_devices` `find_device` `add_device` `device_parameters` `configure_device` |
| **Change tracking** | `checkpoint` `get_changes` `revert_object` |
| **Simulation** | `codesys_sim_start` `codesys_sim_stop` `codesys_sim_status` `codesys_sim_control` `codesys_sim_cycle` `codesys_sim_read` `codesys_sim_write` `codesys_sim_force` `codesys_sim_unforce` `codesys_sim_test` |
| **Trace** | `trace_setup` `trace_record` |
| **Debug** | `breakpoint_set` `breakpoint_on_change` `breakpoint_clear` `debug_status` `debug_step` `debug_continue` `watch` |
| **HMI screens** | `hmi_save_screen` `hmi_template` `hmi_screenshot` `hmi_export_codesys` `hmi_list` `hmi_delete_screen` `open_hmi` `hmi_save_symbol` `hmi_symbols` `hmi_delete_symbol` `hmi_translate` `hmi_pid` |
| **Alarms** | `alarm_list` `alarm_status` `alarm_acknowledge` `alarm_history` `create_alarm_history` |
| **Handover** | `project_report` `export_sources` `compare_sources` `create_recipes` |
| **Helpers** | `batch` `wait` `help` `open_workspace` `show_in_codesys` |
`batch` runs up to 50 actions in one call, which is much faster than separate
calls.
Some actions go beyond what CODESYS's scripting API documents and use CODESYS's
own services inside the IDE: `get_signature`, `find_references`,
`rename_symbol`, `trace_setup`, `trace_record`, the debug actions,
`hmi_export_codesys` (with its alarms and user groups), the alarm actions and
`--show-window`.
They are **experimental**: checked on CODESYS V3.5 SP21 and SP22 as noted in
the [changelog](CHANGELOG.md). On another version they may report that the
feature isn't available, or not work. They don't depend on CODESYS's
language: the native HMI export was checked with a German and a Chinese user
interface too.
Claude writes Structured Text, and creates ladder (LD), FBD, CFC and SFC
programs and function blocks with `create_graphical` from a simple description
of rungs, networks or steps; CODESYS draws them. SFC charts can have alternative
and parallel branches and jumps. Reading an LD, FBD, CFC or SFC POU gives the
same description, so Claude can change existing graphical code too: it edits the
description and sends it back with `replace: true`.
## Live panel
Right after opening or creating a project, Claude opens the panel as a card in
the chat. It shows the status, the object Claude is working on and how many
objects changed. **Open workspace** expands it into a CODESYS-style view with
the project tree, editor tabs, compile problems and a review list.
From the panel you can **Accept** or **Revert** each change, compare it with
the version you last reviewed, and **Pause Claude** while you look around.

The card needs a client that supports
[MCP Apps](https://modelcontextprotocol.io/extensions/apps). In our testing
Claude Desktop draws it in the Code tab but not in a normal chat
([anthropics/claude-ai-mcp#1243](https://github.com/anthropics/claude-ai-mcp/issues/1243)).
Ask Claude to open the workspace in your browser if you'd rather have it there;
the browser never opens by itself.
[More about the panel](docs/reference.md#live-panel)
## HMI screens
Ask Claude for operator screens and it designs them for your program: an
overview of the line's stations, process diagrams, values with their
set-points, trends and alarms, all bound to your PLC variables. The look is a
calm, flat design system (Siemens iX colours, high-performance HMI practice
after ISA-101): colour means a state or something to act on, never decoration.

- **The machine in the frame.** Its state (Production, Fault, Stopped, ...)
sits in the top bar's corner with a thin line in its colour under the bar;
Start, Stop, Reset and the Manual/Auto switch in a bar along the bottom; the
active faults, warnings and messages counted in the top bar; the pages in a
rail on the left. `hmi_template` gives Claude a good layout for each kind of
page. Panels: 1280x720, 1920x1080, 1024x768 or 800x480.
- **An overview of the stations.** A `line` card draws the process as station
tiles on a product path, each with its pictogram, key value and state; a
supply such as steam joins its station from above, and tapping a tile opens
its page.
- **Process diagrams to the standards.** Symbols drawn from ISO 10628-2 (pumps,
fans, valves, check and control valves, heat exchangers, motors on the
machine they drive, agitators, separators, filters, conveyors and more),
instruments as ISA-5.1 bubbles outside the vessel and joined to where they
measure, and pipes that route themselves between named ports
(`T-201.right`, `P-201.in`) with line names and flow arrows at the edges.
- **State at a glance, without clutter.** Three separate things, each with its
own sign, so none hides another: the run state before the name (▶ running,
■ stopped), the mode after it (a hand in Manual; Auto shows nothing) and the
condition at the symbol's corner (an amber warning or a red alarm; OK shows
nothing). A tripped switch (LSH, PSL) gets the same badge at its bubble. A
closed valve is drawn filled, as on a P&ID. Symbols are never
filled grey or coloured by state, and nothing moves.
- **Labels place themselves.** Every name, line name and reading is put where
it touches no pipe, equipment or other text and stays inside the card; a
tank's name goes inside the vessel. A value that belongs to a piece of
equipment, such as a control valve's opening, is shown under its name.
- **Claude checks its own work.** Saving a screen checks the layout (overlaps,
labels without room) and that the diagram is a process: equipment no pipe
reaches, an inlet without an outlet, a heat exchanger with one circuit,
instruments inside a vessel, a motor that drives nothing, a reading drawn
as a separate sensor when it belongs to equipment, or a run state on a
filter. `hmi_screenshot` returns the screen as an image to look at.
- **Your own symbols.** Claude can draw a symbol you need as SVG, or import
yours from an SVG file (`hmi_save_symbol`), and gets back a picture of it
with its ports. Custom SVG is checked against a short list of elements and
attributes: scripts, styles, links and external images are refused.
- **Live in your browser.** Ask Claude to open the HMI (`open_hmi`). The page
is served by the toolkit on 127.0.0.1 with a token, like the workspace.
While CODESYS's simulation runs it shows live values and trends, and
buttons, switches and setpoints write to the simulation, so you can operate
your program before any hardware exists.
- **Light, dark and high-contrast themes,** the same on every page; `accent`
puts your company colour on the highlights, and text on it turns black or
white to stay readable. Screens are saved next to the project as
`<project>.hmi.json`, so they travel with it and can go into version
control.



The HMI writes only into CODESYS's own simulation, like the rest of the
toolkit. Screenshots use Microsoft Edge or Google Chrome, whichever is
installed.
### P&ID sheet
`hmi_pid` exports a screen's process diagram as an engineering P&ID drawing
for documentation and commissioning: the same diagram drawn black on white,
with nothing live, on an A3 sheet with a frame, a legend of the symbols it
uses and a title block (drawing number, revision, date). It is saved next to
the project as PDF, SVG or PNG. Since it comes from the HMI's own diagram,
there is no second drawing to keep up to date.

### As a native CODESYS visualization
`hmi_export_codesys` builds the same screens as real CODESYS visualizations in
your project. They are ordinary visualization objects, so they go with the
application like ones you drew yourself (checked in CODESYS's simulation, not
on a controller): the same frame, cards, symbols, state signs, labels and
station tiles as in the browser, drawn with CODESYS's own elements and
pictures in an embedded image pool. A generated program, `PRG_HMI_<screen>`,
works out what the pictures need (scaled bars and levels, the machine state,
alarm counts). Claude gets a picture of the result.


A multi-page HMI comes out as one visualization per page with the rail of
page buttons, the first page as the start page of TargetVisu and WebVisu at
the panel size, faceplates as CODESYS dialogs, the pages' alarms in CODESYS's
alarm management (Alarm Configuration, with timestamps and acknowledge in the
PLC), and user groups (Operator, Maintenance, Admin) behind a Login button.
Users and passwords are yours to add in the Visualization Manager.
A tile can be limited to a group and up: `access: {min: 'Maintenance'}` lets
lower groups see it without operating it, `below: 'hide'` hides it from them.
The rights go on CODESYS's own elements and also apply when nobody is logged
in.
The alarms are CODESYS's own, not a copy in the HMI: an alarm group with its
observations, classes and messages, which CODESYS's alarm manager evaluates in
the PLC. In the simulation, raising the fault made the group report an active
alarm, and it stayed pending after the fault cleared, until acknowledged, as an
Error-class alarm should.

Claude can test them in the simulation: `alarm_status` reads each alarm's
state from CODESYS's alarm manager (normal, active, active acknowledged,
cleared but waiting for confirmation or acknowledgement), and
`alarm_acknowledge` acknowledges as an operator would. In the browser HMI and
in CODESYS, an alarm row stays until it is acknowledged, with the time it
came, its state and an acknowledge button.
CODESYS's runtime alarm forgets its times once it is normal again, so the
export also adds an alarm history to the PLC: generated ST that records every
state change of every alarm (with CODESYS's own time of the change) in a
RETAIN ring buffer. `alarm_history` lists it, and an alarms tile with
`history: 5` shows the last events, in the browser and in CODESYS
(`create_alarm_history` adds the same to a project with alarms of its own).
Gauges are the same arc gauge as in the browser (pictures in the image pool,
one per 2.5 % of the range), not CODESYS's chrome meter. Trends show their
current values: a CODESYS trend needs a trend recording that scripting can't
create yet. Checked on CODESYS V3.5 SP21 in the simulation. A visualization
needs the `FloatingPointUtils` library in CODESYS's library repository; if
it's missing, the export says so before it builds anything. A long export
reports its progress (each page, the alarms, the compile) to clients that
show MCP progress.
## Handover and version control
`project_report` writes a Markdown report next to the project for whoever
commissions or takes over the machine: a summary, the tasks, the I/O list and
device-tree mappings, the CODESYS alarms, the HMI pages, libraries, devices and
the program structure. It ends with a commissioning checklist built from the
project itself: every task's cycle time, every input and output, every mapped
channel, every alarm, every HMI page and the persistent variables to check on
the real machine, plus the safety and archiving items no checklist should
skip. Everything Claude did was tested in CODESYS's simulation only, and the
report says so.
`export_sources` writes the project as plain text for git: one `.st` file per
POU, method, property, action, DUT, GVL and interface, in folders like the
project tree, ladder/FBD/SFC bodies as PLCopenXML, a `project.txt` with tasks,
libraries, devices and alarms, and the HMI screens. A `.project` file is
binary; this folder is what makes a change reviewable as a diff. Exporting
again rewrites only what changed and removes the files of deleted objects.
`compare_sources` compares the open project with such a folder or with another
`.project` file: the objects only in one of them, and a line diff of each
changed one.
## Other clients and models
The server works with any MCP client, not only Claude. For
[OpenCode](https://opencode.ai), put this in `opencode.json` in your project
folder (or in `~/.config/opencode/opencode.json`):
```json
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"codesys": {
"type": "local",
"command": [
"codesys-mcp-tool",
"--codesys-path", "C:\\Program Files\\CODESYS 3.5.22.40\\CODESYS\\Common\\CODESYS.exe",
"--codesys-profile", "CODESYS V3.5 SP22 Patch 4",
"--workspace", "C:\\PLC\\Projects"
],
"enabled": true
}
}
}
```
`opencode mcp list` should then show `codesys` as connected. Clients that read
an `mcpServers` file (Cursor, Cline, VS Code and others) take the same
`command` and `args` as the Claude Desktop example above.
Tested on 13 November 2026 with OpenCode 1.19.5 and CODESYS V3.5 SP22: each of
these models created a project, read and changed `PLC_PRG`, compiled, listed
libraries and devices, and ran the simulation, without help.
| Model | Result |
| --- | --- |
| DeepSeek V4.1 Flash | All steps passed |
| Qwen 3.6 Plus | All steps passed |
| GLM 5.3 | All steps passed |
| MiniMax M3 | All steps passed |

The live panel needs a client that shows MCP Apps cards (see
[Live panel](#live-panel)). In other clients `open_sim_panel` does nothing
visible; ask the model to open the workspace (`open_workspace`) to get the same
view in your browser, or start the server with
[`--show-window`](#watch-it-in-the-codesys-window) to watch the CODESYS window
itself.

## Safety
- **No real controller.** The toolkit doesn't log in or download to a
controller. It goes online only to CODESYS's own simulation, and every online
call first checks that simulation mode is on.
- **One approval covers every action.** That includes the actions that change
or delete project code, so work on a copy of any project you can't afford to
lose, or keep it in version control.
- **Changes can be undone.** A checkpoint is taken when a project is opened, and
`revert_object` puts an object back to it, including its methods and
properties.
- **Saved as it goes.** The project is saved after every change by default. Use
`--no-autosave` to save only on request.
- **The simulation can't change your project.** Editing is refused while it
runs, and the simulation setting on the device is never saved.
## Configuration
| Option | Meaning |
| --- | --- |
| `--codesys-path <exe>` | `CODESYS.exe` to run |
| `--codesys-profile <name>` | Profile, e.g. `"CODESYS V3.5 SP21"` (file name in `CODESYS\Profiles`, without `.profile.xml`). A name that isn't installed is refused at start, with the installed ones listed |
| `--codesys-additional-folder <dir>` | CODESYS's add-on folder, passed as `--additionalfolder`. SP22 installs add-ons such as Scripting there; the toolkit finds `CODESYS\AdditionalFolders\Default` by itself |
| `--workspace <dir>` | Base folder for relative project paths (default: the working directory). Created if missing |
| `--project <file>` | Open this project as soon as CODESYS is up |
| `--session-dir <dir>` | Where session folders go (default: `%TEMP%\codesys-mcp-toolkit`) |
| `--no-autostart` | Start CODESYS on the first tool call instead of at launch |
| `--no-autosave` | Don't save after every change; use `save_project` |
| `--viewer-port <port>` | Port of the browser workspace on 127.0.0.1 (default 5180, or the next free one) |
| `--no-viewer` | Don't serve the browser workspace |
| `--no-shared` | Run CODESYS in this process instead of the shared session |
| `--attach <dir>` | Experimental: work in a CODESYS / Machine Expert window you already have open, instead of starting one. See [Working in an open window](#work-in-a-window-you-already-have-open-experimental) |
| `--show-window` | Start CODESYS with its window instead of headless. See [Watch it in the CODESYS window](#watch-it-in-the-codesys-window) |
### Watch it in the CODESYS window
By default CODESYS runs headless. With `--show-window` the server starts it with
its normal window, so you can watch the work in any MCP client: every object the
model creates or writes opens in its editor tab, with the new code in it.

While the simulation runs, the open editors show live values, as in CODESYS's own
online mode:

The window is yours to close. Closing it stops the toolkit's script in it, and
CODESYS closes as usual, asking about unsaved changes. The next tool call starts
CODESYS again.
CODESYS's scripting API has no call for opening an editor, so the toolkit uses
CODESYS's own (undocumented) frame for it, checked on SP21 and SP22. If a CODESYS
version doesn't have it, nothing opens and everything else works as before.
While the server is connected, the window is for watching: the toolkit's script
keeps running in it (that is what lets it answer CODESYS's prompts, such as a
storage-format upgrade, the same way as headless), so CODESYS treats it as one
long operation. The status bar says "Executing script"; its **Click here to
CANCEL** link stops the toolkit's script, so leave it alone while you work with
the model. When the server stops, the script ends and the window is yours to
work in.
The toolkit never closes the window: not when a call hangs or a dialog waits
for an answer (answer it in the window), and not when the server stops. Close it
yourself when you're done; the next call then starts a new one.
### Several CODESYS versions
To keep SP21 and SP22 side by side, add one server entry per version, each with
its own `--codesys-path` and `--codesys-profile`.
The toolkit never updates a project's compiler or library versions, and
`open_project` says when they differ from the running CODESYS. A project that
needs a newer compiler opens, but can't compile until you open it in that
version. Each version keeps its own devices and libraries, so a project from an
older CODESYS may report missing libraries until you update it in the CODESYS
window.
### Shared session
Claude Desktop may start the server more than once. All processes started with
the same options share one background session, so only one CODESYS runs and the
panel shows the project Claude is working on. The session stops two minutes
after the last client disconnects. Its log is `daemon-<id>.log` in
`%LOCALAPPDATA%\codesys-mcp-toolkit`.
### Work in a window you already have open (experimental)
`--attach <dir>` makes the server use a CODESYS / Machine Expert window you
already work in, instead of starting a hidden one. It starts nothing and kills
nothing.
1. Add `--attach "C:\\PLC\\attach"` to the server arguments and start the
server. It writes `C:\PLC\attach\scripts\start_attach.py`.
2. In your window, open the project, then run that file with **Tools >
Scripting > Execute Script File**. It returns at once; a UI timer polls for
requests, so the window stays usable.
3. Use the `codesys` tool as usual. `open_project` on the project that is
already open just reuses it.
4. To stop, create an empty file `stop.flag` in the attach folder (or close the
window).
The window is busy only while a request runs, for example during `compile`.
Your own unsaved edits are saved with the next change Claude makes
(autosave), so use `--no-autosave` if that is not what you want. If the window
stops answering (a dialog is open), the call fails with an error and nothing is
closed; run `start_attach.py` again if the watcher was stopped.
## How it works
```
MCP client ── stdio ──▶ codesys-mcp-tool (Node.js)
│ requests/<id>.json ▶ operation name + JSON arguments
│ ◀ results/<id>.json
│ ◀ heartbeat.json idle or busy, with a deadline
▼
CODESYS.exe --noUI --runscript=watcher.py
└─ fixed operation handlers (IronPython 2.7)
```
With `--show-window`, CODESYS starts without `--noUI` and runs the same watcher.
- **No generated code.** Requests are an operation name plus JSON arguments,
handled by fixed functions in `watcher/mcp_ops.py`.
- **Hang detection.** The watcher reports `busy` with a deadline. If CODESYS
blocks past it, the server kills it and starts a fresh one on the next call.
- **No orphans.** The watcher exits when the server process goes away.
- **Modal dialogs** are suppressed and logged, so they can't freeze CODESYS.
- **UTF-8** from end to end.
- **Localised names.** Object kinds come from CODESYS type GUIDs, not names, so
a German task folder called `Taskkonfiguration` works.
## Troubleshooting
| Message | What to do |
| --- | --- |
| **CODESYS is still starting** | The first start after boot can take minutes. Check `codesys_status`, then try again. |
| **`startup_failed`** or **`startup_timeout`** | Check the profile name and that CODESYS starts by hand. The error includes the last lines of `watcher.log`. |
| **Library errors after `create_project`** ([#4](https://github.com/johannesPettersson80/codesys-mcp-toolkit/issues/4)) | The default template is brought up to the running CODESYS, so its libraries should resolve. A template you pass yourself is used as it is. If libraries are still missing, install them with the CODESYS Library Repository. |
| **`hung`** or **`timeout`** | CODESYS was restarted. Re-open the project. With `--show-window` nothing is closed: check the window. |
| **`dialog`** | CODESYS opened a dialog, named in the error, that a session without a window can't answer. CODESYS was stopped and restarts on the next call. Do the same step once in the CODESYS window, answer the dialog there, and try again. With `--show-window`, answer it in the window. |
Each session folder keeps a `watcher.log`.
## Development
```bash
npm install
npm test # unit, bridge and tool tests (no CODESYS needed)
CODESYS_LIVE=1 npx vitest run test/live # end-to-end against your CODESYS
npm run build # server and the single-file panel
```
The normal tests run the real watcher under CPython 3 against a fake
`scriptengine` (`test/fake/`). Watcher code must stay valid IronPython 2.7:
ASCII-only, no f-strings.
To work on the panel without Claude Desktop, run the dev host, then open
http://localhost:5199:
```bash
npm run build:panel && node scripts/dev-host/run.mjs 5199
```
See [CONTRIBUTING.md](CONTRIBUTING.md) to get involved.
## Migrating from v1
- Everything is now an action of the one `codesys` tool.
- Actions don't take `projectFilePath`. Call `open_project` once.
- `create_pou`, `create_method` and `create_property` are now `create_object`
with a `kind`.
- `set_pou_code` is now `write_object`.
- `compile_project` is now `compile`, and it returns the errors.
- Read access is through actions (`read_objects`, `get_project_tree`) instead of
resources, so it works in Claude Desktop
([#6](https://github.com/johannesPettersson80/codesys-mcp-toolkit/issues/6)).
## Acknowledgements
The persistent-watcher design borrows ideas from
[zbest1000/mcptoolkit-for-codesys](https://github.com/zbest1000/mcptoolkit-for-codesys)
(op-handler registry, heartbeat, prompt handling) and
[phobicdotno/Codesys-MCP-Master](https://github.com/phobicdotno/Codesys-MCP-Master)
(file-queue IPC, version-safe opening). Both are MIT-licensed.
The [Chinese README](README.zh-CN.md) was reviewed by Zhen Yang (Alfabete-spec).
## License
[MIT](LICENSE)
CODESYS is a trademark of CODESYS GmbH. This project is independent and isn't
affiliated with or endorsed by CODESYS GmbH.
This server cannot be deployed
Maintenance
ActivityMaintained
ResponsivenessOutdated data