Skip to main content
Glama

LV Forge

LV Forge brings LabVIEW VI review into an MCP client. Use it to trace the wiring in a saved block diagram, compare two revisions of a VI, or ask the LabVIEW IDE whether a VI is runnable.

Capabilities

Tool

Use it to

Source

lv_inspect

Inspect nodes, wiring, and connector pane terminals. The result includes the saved file's SHA-256 hash.

Saved VI

lv_diff

Compare two saved VIs for changes in diagram structure and dataflow.

Two saved VIs

lv_render

Generate a temporary SVG of a block diagram.

Saved VI

lv_check

Read the execution state and runnability reported by the IDE.

Live LabVIEW IDE

lv_report

Generate a self-contained HTML inspection report with the VI hash, saved version, diagram, and diagnostics.

Saved VI, with an optional live IDE check

The offline tools use LVKit and can work without a running IDE. The live check uses Windows ActiveX and has been verified with LabVIEW 2020 32-bit. It may load the VI into the IDE. It never executes or saves the VI. Exact broken-wire counts and unsaved-edit status are reported as unknown.

Offline results include warnings, notices, and a partial_analysis flag. LV Forge uses a fresh temporary LVKit cache for each call so cached results do not suppress parser warnings. It preserves usable partial output and surfaces warnings even when LVKit exits successfully. Inspect the warnings before relying on a diagram or diff. The lv_diff result contains its text in the diff field.

Related MCP server: EPLAN MCP Server

Install

Use Python 3.11 or newer. Run these commands in PowerShell:

git clone https://github.com/harisunder1991/lv-forge.git
cd lv-forge
py -3.11 -m venv .venv
.\.venv\Scripts\python.exe -m pip install -r requirements.txt

Try the bundled examples

Run this from the repository root:

.\.venv\Scripts\python.exe examples\quickstart.py

The demo inspects the array-sum VI, compares it with the array-product VI, and prints the path to an SVG. It runs offline by default. To try the live check, start LabVIEW and add --live. See the example guide for the opt-in COM activation option and expected results.

Connect your MCP client

For clients that accept an mcpServers JSON configuration, replace C:/path/to/lv-forge with the full path to your checkout. The client launches LV Forge over stdio.

{
  "mcpServers": {
    "lv-forge": {
      "command": "C:/path/to/lv-forge/.venv/Scripts/python.exe",
      "args": ["C:/path/to/lv-forge/server.py"]
    }
  }
}

Give your client the absolute paths to the VIs you want to review. For example, ask it to compare examples/Sample_Add.vi and examples/Sample_Multiply.vi, then explain the change inside the loop.

If the offline diagram differs from what you see in LabVIEW, check whether your edits have been saved. If lv_check cannot attach, open LabVIEW and retry. You can pass allow_com_activation: true when COM may launch the registered LabVIEW version.

Save a VI inspection report

Ask the MCP client to call lv_report with the absolute path to a saved VI. Open the returned report_path in a browser and copy the HTML out of the temporary folder if you want to retain it. It includes a UTC timestamp, the saved LabVIEW version when available, detected inputs and outputs, named SubVI calls, the embedded SVG, and any analysis warnings.

Set include_live_check: true to add the IDE's runnability result in a separate section. The report records inspection evidence. Keep functional test results with it when documenting validation.

Known limitations

  • Partial parses on LabVIEW 2020. LVKit can report a VITS parse warning on the bundled Add and Multiply VIs while still extracting the diagrams. Larger VIs can produce other parser warnings or fallback control labels. Check partial_analysis and warnings before relying on the extracted data.

  • The reported SubVI list can be empty or incomplete. The HTML report lists named calls found in the extracted diagram. Unresolved calls, dynamically selected VIs, and calls omitted by a partial parse can be absent.

  • lv_check is limited to the IDE's execution state and associated runnability. It cannot identify the exact broken wire, count broken wires, or detect unsaved diagram edits. See the report's saved-file section for the offline evidence.

Contributing

Useful first contributions include testing the live check across LabVIEW versions and adding reproducible fixture cases for diagram inspection. In bug reports, include Windows and Python versions, LabVIEW version and bitness, the tool and arguments used, and a minimal example you have permission to share.

Run the unit tests from the checkout with .\.venv\Scripts\python.exe -m unittest discover -s tests. The tests mock the LabVIEW connection. They do not require opening or running a VI.

Credits

Harisunder Chidambaram created LV Forge's standalone MCP integration. LV Forge provides the tool interface, input validation, result reporting, and the live Windows LabVIEW check.

OpenAI Codex (ChatGPT's coding agent) helped implement, test, and package the standalone release. Google Antigravity helped investigate and verify LabVIEW 2020 VI Scripting and compatibility in the earlier internal prototype.

LV Forge is distributed under the MIT License.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      Not graded
      quality
      C
      maintenance
      Enables inspection of existing KiCad boards and schematics — layer/component/net reading, native DRC and ERC, XML netlist generation, Gerber/Excellon export, and GND continuity auditing — plus running LTspice or ngspice simulations with RAW waveform summaries and CSV export. It checks existing designs and preserves artifacts and evidence rather than performing GUI editing, auto-placement, or auto-routing.
      Apache 2.0
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables source-preserving import and analysis of EPLAN export reports (devices, connections, PLC I/O, terminals, cables, parts, network, pages) as immutable queryable snapshots, plus inspection of DXF/PDF/DWG drawings and derivation of electrical project evidence. Works offline without EPLAN, supporting querying, duplicate/endpoint checks, revision comparison, and verified JSON export.
      MIT
    • A
      license
      Not graded
      quality
      C
      maintenance
      Enables AI assistants to read, extend, and validate LabVIEW CSM state-machine VIs, inspecting case branches and exposed APIs, generating modules from official templates, and injecting new states with automatic shift-register and error-cluster tunnel wiring. Also formats complex CSM message arguments, mounts VIs into .lvproj trees, and audits projects for deadlocks, orphan states, and missing documentation.
      1
      Mulan Permissive Software , Version 2
    • A
      license
      A
      quality
      B
      maintenance
      Enables AI coding agents like Claude Code, Codex, and Cursor to inspect, render, and execute binary NI LabVIEW VIs by driving an installed LabVIEW instance over ActiveX. Returns VI strings, PNG snapshots of diagrams and panels, subVI call trees, and front-panel values from runs.
      19