B&R Automation Studio MCP Server
Enables interaction with B&R Automation Studio projects, allowing for project compilation, launching the ARsim simulator, and reading or writing PLC variables in real-time through OPC UA integration.
This server does not currently have a deployable release on Glama. Follow the repository's setup instructions to install and configure it for your MCP client, including any required credentials and local dependencies.
B&R Automation Studio MCP Server
An MCP (Model Context Protocol) server that enables AI assistants like Claude to interact with B&R Automation Studio projects. Build projects, run simulators, and read/write OPC UA variables - all through natural language.
Features
Build Projects - Compile Automation Studio projects for simulation
Run Simulator - Launch ARsim and connect automatically
OPC UA Integration - Read and write PLC variables in real-time
Related MCP server: PLCs.ai MCP Server
Prerequisites
Windows 10/11 with B&R Automation Studio 4.x installed
Python 3.10+ on Windows (with pip)
Claude Code (native Windows or WSL2)
Installation
1. Clone this repository
git clone https://github.com/AndrewMusser/br-automation-mcp.git
cd br-automation-mcp2. Install Python dependencies
pip install -r requirements.txt3. Configure server settings
Edit server.py to match your environment:
3a. B&R Tool Paths
Update these paths to match your Automation Studio installation:
AS_BUILD_PATH = "C:\\BrAutomation\\AS412\\bin-en\\BR.AS.Build.exe"
PVI_TRANSFER_PATH = "C:\\BrAutomation\\PVI\\V4.12\\PVI\\Tools\\PVITransfer\\PVITransfer.exe"Common installation locations:
AS 4.12:
C:\BrAutomation\AS412\bin-en\BR.AS.Build.exeAS 4.9:
C:\BrAutomation\AS49\bin-en\BR.AS.Build.exePVI: Typically under
C:\BrAutomation\PVI\V4.x\PVI\Tools\PVITransfer\
3b. OPC UA Parameters
Configure the OPC UA connection settings for communicating with ARsim:
OPCUA_HOST = "localhost"
OPCUA_PORT = 4840
OPCUA_USERNAME = "Admin"
OPCUA_PASSWORD = "password"Important: These credentials must match your Automation Studio project's OPC UA configuration:
User/role settings:
Physical/<Config>/<CPU>/AccessAndSecurity/UserRoleSystem/OPC UA config:
Physical/<Config>/<CPU>/Connectivity/OpcUA/
4. Configure Claude Code
Choose the setup that matches how you run Claude Code:
Option A: Native Windows (Recommended)
Claude Code now runs natively on Windows via Git Bash, PowerShell, or CMD. This is the simplest setup since both Claude Code and Automation Studio run on the same machine.
Install Claude Code on Windows:
winget install Anthropic.ClaudeCodeConfiguration file: %APPDATA%\Claude\settings.json
Add to settings:
{
"mcpServers": [
{
"name": "br-automation-mcp",
"type": "stdio",
"command": "python",
"args": ["D:\\path\\to\\br-automation-mcp\\server.py"],
"enabled": true
}
]
}Architecture:
┌─────────────────────────────────────────────────────────────┐
│ Windows │
│ │
│ ┌─────────────┐ ┌─────────────────────────────────────┐ │
│ │ Claude Code │───▶│ server.py (MCP STDIO Server) │ │
│ │ (Git Bash) │ └───────────────┬─────────────────────┘ │
│ └─────────────┘ │ │
│ │ │
│ ┌───────────────────────────┼───────────────┐ │
│ ▼ ▼ ▼ │
│ ┌─────────────┐ ┌──────────────┐ ┌─────────┐ │
│ │ BR.AS.Build │ │ PVITransfer │ │ OPC UA │ │
│ │ (Build) │ │ (Simulate) │ │ (Test) │ │
│ └─────────────┘ └──────────────┘ └─────────┘ │
└─────────────────────────────────────────────────────────────┘Option B: WSL2 (Cross-Platform)
If you run Claude Code in WSL2, it can invoke the Windows Python server via PowerShell interop.
Configuration file: ~/.claude/settings.json
Add to settings:
{
"mcpServers": [
{
"name": "br-automation-mcp",
"type": "stdio",
"command": "powershell.exe",
"args": [
"-ExecutionPolicy",
"Bypass",
"-File",
"D:\\path\\to\\br-automation-mcp\\run-server.ps1"
],
"enabled": true
}
]
}Architecture:
┌─────────────────────────────────────────────────────────────┐
│ WSL2 (Linux) │
│ ┌─────────────────┐ │
│ │ Claude Code │ │
│ │ │──── powershell.exe ────┐ │
│ └─────────────────┘ │ │
└─────────────────────────────────────────────│───────────────┘
│
┌─────────────────────────────────────────────│───────────────┐
│ Windows ▼ │
│ ┌─────────────────┐ ┌─────────────────────────────────┐ │
│ │ run-server.ps1 │───▶│ server.py (MCP STDIO Server) │ │
│ └─────────────────┘ └───────────────┬─────────────────┘ │
│ │ │
│ ┌───────────────────────────────┼───────────────┐ │
│ ▼ ▼ ▼ │
│ ┌─────────────┐ ┌──────────────┐ ┌─────────┐ │
│ │ BR.AS.Build │ │ PVITransfer │ │ ARsim │ │
│ │ (Build) │ │ (Simulate) │ │ (OPC UA)│ │
│ └─────────────┘ └──────────────┘ └─────────┘ │
└─────────────────────────────────────────────────────────────┘5. Restart Claude Code
After updating the configuration, restart Claude Code to load the MCP server.
Available Tools
build_automation_studio_project
Compiles an Automation Studio project for simulation.
Parameters:
project_file- Path to the .apj file (Windows path)configuration- Name of the configuration to build
Example prompt: "Build my project at D:\Projects\MyApp\MyApp.apj using the X20CPU configuration"
run_automation_studio_simulator
Creates ARsim structure and launches the simulator.
Parameters:
ruc_package- Path to RUCPackage.zip (generated by build)start_simulator- Whether to start immediately (default: true)
Example prompt: "Start the simulator using the RUC package at D:\Projects\MyApp\Binaries\X20CPU\X20CP1686X\RUCPackage\RUCPackage.zip"
opcua_read_write
Reads or writes OPC UA variables on the running simulator.
Parameters:
node_id- OPC UA node identifier (e.g.,ns=6;s=::TaskName:varName)operation- "read" or "write"value- Value to write (for write operations)value_type- Data type: Boolean, Int16, Int32, Float, Double, String
Example prompts:
"Read the temperature variable from the TempCtrl task"
"Set the targetTemp to 75.0 in the TempCtrl task"
OPC UA Node ID Format
For task-local variables:
ns=6;s=::<TaskName>:<VariableName>For global variables:
ns=6;s=::AsGlobalPV:<VariablePath>Note: Variables must be exposed in the OPC UA configuration (OpcUaMap.uad) to be accessible.
Troubleshooting
"Command not found" errors
Ensure Python is in your Windows PATH and the B&R tool paths in server.py are correct.
OPC UA connection failures
Verify the simulator is running
Check that variables are exposed in OpcUaMap.uad
Default credentials are Admin/password
WSL2 can't find powershell.exe
Ensure WSL2 has Windows interop enabled (default). Check with:
which powershell.exeLicense
MIT License - see LICENSE for details.
Contributing
Contributions are welcome! Please feel free to submit issues and pull requests.
Acknowledgments
Model Context Protocol by Anthropic
FastMCP for the Python MCP SDK
B&R Automation for Automation Studio
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
This server cannot be deployed
Maintenance
Related MCP Connectors
Connect AI assistants to your approved computer for files, commands, browser and desktop tasks.
- DNS-DATA RemoteDeprecatedcom.dns-data
Connect AI assistants to authorized Windows and macOS devices for files, commands, and management.
Build and run agents and automations across hundreds of apps using natural language.
Connect AI assistants to GitHub - manage repos, issues, PRs, and workflows through natural language.
Related MCP Servers
- AlicenseAqualityBmaintenanceAutomates the Sigmatek LASAL software suite for PLC and HMI engineering, enabling AI assistants to inspect projects, apply structural changes, compile, download to hardware, and control PLC runtime.2023210 npm2MIT
- FlicenseNot gradedqualityCmaintenanceEnables AI agents to connect to Allen-Bradley, Siemens, and CODESYS PLC projects for discovering, asking questions about, analyzing, and proposing code changes, with access to live tag values and version exports under permission-scoped controls.-
- AlicenseNot gradedqualityBmaintenanceEnables AI assistants to automate CODESYS V3 PLC development, including project editing, builds, library and alarm management, online variable read/write/force operations, and CODESYS documentation search via MCP.4MIT
- AlicenseAqualityCmaintenanceEnables AI assistants to access structured PLC brand, IEC 61131-3 language, and code-template knowledge so they can generate IDE-specific automation code from natural-language requests.5MIT