Skip to main content
Glama
REW MCP Server

REW MCP Server

by fl0zan0

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault

No arguments

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": true
}
logging
{}
prompts
{
  "listChanged": true
}
resources
{
  "subscribe": true,
  "listChanged": true
}

Tools

Functions exposed to the LLM to take actions

NameDescription
rew_ingest_measurementC

Parse and store a REW measurement export for analysis. Accepts frequency response or impulse response data in REW text export format.

rew_compare_measurementsB

Compare two or more REW measurements to determine what improved, worsened, or stayed the same. Supports pre/post GLM comparison, placement comparisons, and L/R symmetry analysis.

rew_analyze_room_modesB

Analyze a measurement for room modes, peaks, and nulls. Optionally correlates detected issues with theoretical room modes based on room dimensions.

rew_analyze_decayB

Analyze decay characteristics from impulse response data to identify frequencies with excessive ringing or resonance. Implements ISO 3382 compliant T20/T30/EDT calculations.

rew_analyze_impulseC

Analyze impulse response data to detect early reflections, estimate reflection paths, and assess their impact on sound quality.

rew_interpret_with_glm_contextC

Interpret measurement analysis results considering Genelec GLM's capabilities and limitations. Explains what GLM can address, what requires physical solutions, and provides calibration-aware recommendations.

rew_average_measurementsA

Create a spatial average from multiple measurement positions. Implements REW's averaging methods: RMS (incoherent, recommended for spatial averaging), Vector (coherent, requires phase data), or hybrid methods. Useful for multi-position room calibration.

rew_analyze_roomA

Comprehensive room analysis combining peaks/nulls, room modes, sub integration, and L/R symmetry. Returns top 5 prioritized recommendations based on fixability-first scoring (60% fixability + 40% severity). Automatically handles missing optional inputs.

rew_api_connectA

Connect to a running REW instance's REST API. REW must be launched with -api flag or have API enabled in preferences. Default port is 4735.

rew_api_list_measurementsA

List all measurements available in the connected REW instance. Requires prior connection via rew_api_connect.

rew_api_get_measurementA

Fetch a measurement directly from REW via API. Use UUID (not index) to identify measurements, as indices shift when measurements are added/removed.

rew_compare_to_targetB

Compare a measurement against a target response curve. Supports flat, REW room curve (LF rise + HF fall), Harman curve, or custom curves. Provides deviation statistics and recommendations.

rew_api_measureB

Control REW measurements via API. Actions: status (get config), sweep (trigger measurement), spl (SPL measurement), cancel, configure. Note: Automated sweep measurements require REW Pro license.

rew_api_audioB

Configure REW audio devices via API. Actions: status, list_devices, set_input, set_output, set_sample_rate. Use to select measurement mic and output device.

rew_api_generatorC

Control REW signal generator via API. Generate test tones, pink noise, sweeps. Actions: status, start, stop, set_signal, set_level, set_frequency, list_signals.

rew_api_spl_meterB

Control REW SPL meter via API for live level monitoring. Supports A/C/Z weighting, Slow/Fast/Impulse response. Actions: start, stop, read, configure.

rew_api_measure_workflowB

Complete measurement workflow orchestration. Actions: setup (auto-configure devices), check_levels (verify signal chain), calibrate_level (target SPL), measure (single sweep), measure_sequence (L/R or multi-position). Handles device selection, blocking mode, and result retrieval automatically. Note: Sweep measurements require REW Pro license.

rew_api_calibrate_splA

Semi-automated monitor level calibration workflow. Actions: start (play pink noise + start SPL meter), check (read current SPL + get adjustment guidance), stop (end calibration). Guides user to target SPL (default: 85 dB broadcast reference) with configurable tolerance.

rew_api_check_levelsA

Check input levels for mic gain calibration. Reads RMS/peak dBFS and provides zone-based feedback (Clipping, Hot, Optimal, Low, Very Low) with adjustment guidance. Blocks measurement for clipping or very low conditions.

rew_api_measurement_sessionB

Guided L/R/Sub measurement workflow with session state. Actions: start_session (create new), measure (trigger measurement), get_status (check progress), stop_session (end). Sessions persist across tool calls and can be resumed. REW Pro license required for automated measurements.

rew_optimize_roomA

Get placement recommendations, validate adjustments, and track optimization progress. Actions: get_recommendation (next issue to fix), validate_adjustment (check if change helped), check_progress (overall status toward +-3dB target). One recommendation at a time for scientific approach.

rew_api_measurement_commandsC

Execute per-measurement commands via API. Actions: list_commands (get available commands for a measurement), execute (run a command on a measurement).

rew_api_measurement_eqC

Manage per-measurement EQ settings via API. Actions: get_equaliser, set_equaliser, get_filters, set_filters, get_target, set_target, predicted_response, filter_response, match_target.

rew_api_importC

Import measurement data into REW via API. Actions: frequency_response_file, frequency_response_data, impulse_response_file, impulse_response_data, rta_file, sweep_recording.

rew_api_eqC

Manage global EQ defaults and settings via API. Actions: list_equalisers, list_manufacturers, get_defaults, set_defaults, get_house_curve, set_house_curve.

rew_api_groupsC

Manage measurement groups via API. Actions: list, create, get, update, delete, list_measurements, add_measurement, remove_measurement.

rew_api_rtaC

Control REW Real-Time Analyzer via API. Actions: start, stop, capture, reset, configure, read_levels, read_captured, read_distortion.

Prompts

Interactive templates invoked by user choice

NameDescription
rew_calibration_fullComplete studio calibration: gain staging, L/R/Sub measurement, room analysis, optimization guidance
rew_gain_stagingCalibrate monitor levels to target SPL using pink noise and SPL meter
rew_measurement_workflowGuided L/R/Sub measurement with session state tracking
rew_optimization_workflowIterative placement optimization with measurement validation

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3/5.0

Scored across 27 tools

Disambiguation2/5

Several tools have overlapping boundaries: rew_api_measure, rew_api_measure_workflow, rew_api_measurement_session, rew_api_calibrate_spl, and rew_api_check_levels all touch triggering measurements and calibration, so an agent can easily misselect. Additionally rew_analyze_room is a superset that duplicates rew_analyze_room_modes and the L/R symmetry of rew_compare_measurements, rew_api_eq overlaps rew_api_measurement_eq (global vs per-measurement), and rew_ingest_measurement overlaps rew_api_import.

Naming Consistency3/5

There is a consistent snake_case style and clear prefix families (rew_api_*, rew_analyze_*, rew_compare_*, rew_optimize_*), which is good. However two paradigms coexist: some tools are verb_noun (rew_api_list_measurements, rew_api_get_measurement) while others are resource containers driven by an action parameter (rew_api_eq, rew_api_groups, rew_api_measurement_eq), making the pattern only partially predictable.

Tool Count3/5

27 tools is on the heavy side for a room-acoustics calibration server, and the workload is partly inflated by overlapping measurement/calibration wrappers. Many tools legitimately cover distinct hardware resources (RTA, generator, SPL meter, audio devices), but the total feels bloated rather than tightly scoped.

Completeness4/5

The surface is broadly complete for the domain: connect/list/get, measurement orchestration, analysis (room modes, decay, impulse, target compare), EQ, groups, import, and optimization workflow are all covered. Minor gaps remain, such as deleting individual measurements and exporting results, but core lifecycle coverage is strong.

Maintenance

ActivityMaintained
ResponsivenessNo recent community issues