Skip to main content
Glama
TwinPALS-MCP

TwinPALS-MCP

by dpscience

TwinPALS 2.0

Cite this software · Danny Petschke, TwinPALS 2.0, version 2.0.0. When publishing results, please also cite Dominik Boras’s 2024 doctoral dissertation on the PALS digital twin. Software citation (CITATION.cff) · Dissertation (DOI)

TwinPALS simulates positron annihilation lifetime spectroscopy (PALS) on Windows x64. Set up a detector, acquire digitized pulse pairs and see how timing, filters and event selection affect the lifetime spectrum. The desktop and MCP server share the same simulation engines and component catalogue.

Na-22 simulation with particle tracks in the detector assembly and the resulting anode current

Digitizer setup

Waveform acquisition

Lifetime analysis

Two PMT channels connected to a digitizer and coincidence trigger

Digitized pulses and trigger timing for channels A and B

Lifetime and pulse-height spectra before and after filtering

Run the desktop

Download a Windows x64 build from Releases. Run TwinPALS-…-setup.exe for a Start menu entry and automatic reuse of your catalogue on updates. For a portable copy, extract the entire ZIP to a writable folder and open TwinPALS.exe. Both include the scientific runtime. The tray icon reopens the workbench.

Related MCP server: analysis-mcp-server

Run a study with an MCP client

Codex, Claude and GitHub Copilot can run the three modules locally, compare analysis settings on the same recorded pulses, and save a report linked to the underlying runs.

In PowerShell, open the program folder (by default %LOCALAPPDATA%\Programs\TwinPALS 2.0 for Setup) or the extracted portable folder and print the configuration for your client.

.\TwinPALS-MCP.exe --print-config claude-desktop

Replace claude-desktop with codex, claude-code, copilot-cli or vscode as appropriate. Add the printed entry to the client's MCP configuration, reconnect and ask it to call capabilities. The client starts the local server. Choose Open study observer in the tray to follow its work. Client configuration and study examples

Try a zero-lifetime timing study

This study measures the simulated instrument response function (IRF). Each cell of a 9 × 9 grid uses the same waveform pairs. The row sets the constant-fraction (CF) level in A and the column sets it in B. Paste this prompt into your connected client.

Find the CF levels for A and B that minimize the simulated coincidence IRF FWHM.

Use Na-22 and record the detector, digitizer and source timing settings. In Module 2
use exactly one discrete lifetime component: tau = 0 ps, intensity = 100%.
Keep detector timing spread, electronic noise and digitizer jitter at their
configured values. Generate one pulse stream for the entire scan. Record its seed.

In Module 3, vary CF independently in A and B from 10% to 90% in steps of 10%.
Run all 81 combinations on that stream. Keep the PHS windows, filters, cable
correction, histogram range and bin width fixed throughout.

Use the merged ideal/intended same-decay contribution for the prompt peak.
Measure its full width at half maximum in ps using one method for all settings.
State how you determine the baseline and interpolate both half-height crossings.
Record the peak counts and accepted fraction. Flag unresolved widths and acquire
more statistics if needed. Treat statistical ties as ties.

Produce a 9 x 9 FWHM heatmap and a table. Give the best independent CF levels
(A, B) and the best shared level (A = B). Cross-check the best settings on
a new independent seed. Save a Markdown report with uncertainties and run IDs.

Component catalogue

Photomultiplier tube

Sample material

Hamamatsu R329-02 window and photocathode geometry

Aluminium composition and lifetime tabs in the material editor

The factory catalogue contains 396 entries. Expand a family to see every supplied material, tube or acquisition preset.

Included

Catalogue family

Entries

Use

✓

Scintillators

15

Light generation and optical transport

✓

Optical coupling

2

Interface between crystal and PMT window

✓

Photomultiplier tubes

16

Photocathode and anode response

✓

Digitizer presets

41

Sampling and voltage-range configurations

✓

Reflector wrappings

2

Crystal surface and reflectance

✓

Sample materials

309

Source sandwich and positron lifetimes

✓

Encapsulation foils

6

Source encapsulation and foil lifetimes

✓

Shielding materials

5

Particle transport through shielding

Entry

Model light yield (photons/MeV)

BaF₂

11500

BC-418

10200

BC-422Q 0.5%

2900

BC-422Q 1%

1700

BC-422Q 2%

770

BC-422Q 3%

610

BC-422Q 5%

460

CeBr₃

60000

EJ-232

8400

EJ-232Q 0.5%

2900

EJ-232Q 1%

1700

EJ-232Q 2%

770

EJ-232Q 3%

610

EJ-232Q 5%

460

LYSO:Ce

33200

Entry

Density (g/cm³)

Air

0.00120479

EJ-550 silicone grease

1.06

Entry

Model rise time (ns)

ET Enterprises 9214B

3

Hamamatsu R11265U-100

1.3

Hamamatsu R11265U-20

1.3

Hamamatsu R11265U-200

1.3

Hamamatsu R11265U-300

1.3

Hamamatsu R1450

1.8

Hamamatsu R1828-01

1.3

Hamamatsu R2059

1.3

Hamamatsu R2083

0.8

Hamamatsu R329-02

2.6

Hamamatsu R3377

0.8

Hamamatsu R5320

0.7

Hamamatsu R7400U-06

0.78

Hamamatsu R9800

1

Photonis XP2020

1.5

Photonis XP2020Q

1.5

Entry

ADC resolution (bits)

Acqiris DP240-002 · 0.5 GS/s · ±100 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±1000 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±25 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±250 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±2500 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±50 mV

8

Acqiris DP240-002 · 0.5 GS/s · ±500 mV

8

Acqiris DP240-003 · 1 GS/s · ±100 mV

8

Acqiris DP240-003 · 1 GS/s · ±1000 mV

8

Acqiris DP240-003 · 1 GS/s · ±25 mV

8

Acqiris DP240-003 · 1 GS/s · ±250 mV

8

Acqiris DP240-003 · 1 GS/s · ±2500 mV

8

Acqiris DP240-003 · 1 GS/s · ±50 mV

8

Acqiris DP240-003 · 1 GS/s · ±500 mV

8

Acqiris SA220P · 1 GS/s · ±1250 mV

14

Acqiris SA220P · 1 GS/s · ±250 mV

14

Acqiris SA220P · 2 GS/s · ±1250 mV

14

Acqiris SA220P · 2 GS/s · ±250 mV

14

LeCroy WavePro 960 · 8 GS/s · ±500 mV

8

PSI DRS4 V5 · 1.00721 GS/s

14

PSI DRS4 V5 · 1.98194 GS/s

14

PSI DRS4 V5 · 5.12 GS/s

14

Teledyne LeCroy WavePro 254HD · 20 GS/s · ±200 mV

12

Teledyne LeCroy WavePro 254HD · 20 GS/s · ±400 mV

12

Teledyne LeCroy WavePro 404HD · 20 GS/s · ±200 mV

12

Teledyne LeCroy WavePro 404HD · 20 GS/s · ±400 mV

12

Teledyne LeCroy WavePro 604HD · 20 GS/s · ±200 mV

12

Teledyne LeCroy WavePro 604HD · 20 GS/s · ±400 mV

12

Teledyne LeCroy WavePro 804HD · 20 GS/s · ±200 mV

12

Teledyne LeCroy WavePro 804HD · 20 GS/s · ±400 mV

12

Teledyne LeCroy WaveRunner 9254 · 20 GS/s · ±200 mV

8

Teledyne LeCroy WaveRunner 9254 · 20 GS/s · ±400 mV

8

Teledyne LeCroy WaveRunner 9254M · 40 GS/s · ±200 mV

8

Teledyne LeCroy WaveRunner 9254M · 40 GS/s · ±400 mV

8

Teledyne LeCroy WaveRunner 9404 · 20 GS/s · ±200 mV

8

Teledyne LeCroy WaveRunner 9404 · 20 GS/s · ±400 mV

8

Teledyne LeCroy WaveRunner 9404M · 40 GS/s · ±200 mV

8

Teledyne LeCroy WaveRunner 9404M · 40 GS/s · ±400 mV

8

Teledyne SP Devices ADQ14DC-2A · 0.5 GS/s · ±250 mV

14

Teledyne SP Devices ADQ14DC-2C · 1 GS/s · ±250 mV

14

Teledyne SP Devices ADQ14DC-2X · 2 GS/s · ±500 mV

14

Entry

PTFE powder — reflectance model

PTFE — measured LUT

87 of 309 entries include positron-lifetime components. A dash indicates that this entry supplies composition only.

Entry

Lifetime data

1,2-Dichlorobenzene

—

1,2-Dichloroethane

—

A-150 Tissue

—

Ac

✓

Acetone

—

Acetylene

—

Adenine

—

Adipose Tissue Icrp

—

Air

—

Alanine

—

Aluminium

✓

Aluminum Oxide

—

Am

✓

Amber

—

Ammonia

—

Aniline

—

Anthracene

—

Ar

✓

As

✓

At

—

B

—

B-100 Bone

—

Ba

✓

Bakelite

—

Barium Fluoride

—

Barium Sulfate

—

Benzene

—

Beryllium

✓

Beryllium Oxide

—

Bgo

—

Bismuth

✓

Bk

✓

Blood Icrp

—

Bone Compact Icru

—

Bone Cortical Icrp

—

Boron Carbide

—

Boron Oxide

—

Br

✓

Brain Icrp

—

Brass

—

Bronze

—

Butane

—

C

✓

C-552

—

Ca

✓

Cadmium

✓

Cadmium Telluride

—

Cadmium Tungstate

—

Calcium Carbonate

—

Calcium Fluoride

—

Calcium Oxide

—

Calcium Sulfate

—

Calcium Tungstate

—

Carbon Dioxide

—

Carbon Tetrachloride

—

Ce

✓

Cellulose Butyrate

—

Cellulose Cellophane

—

Cellulose Nitrate

—

Ceric Sulfate

—

Cesium Fluoride

—

Cesium Iodide

—

Cf

—

Chlorobenzene

—

Chloroform

—

Chromium

✓

Cl

✓

Cm

✓

Cobalt

✓

Concrete

—

Copper

✓

Cr39

—

Cs

✓

Cyclohexane

—

Cytosine

—

Dacron

—

Deoxyribose

—

Dichlorodiethyl Ether

—

Diethyl Ether

—

Dimethyl Sulfoxide

—

Dna Adenine

—

Dna Cytosine

—

Dna Deoxyribose

—

Dna Guanine

—

Dna Phosphate

—

Dna Thymine

—

Dna Uracil

—

Dy

✓

Er

✓

Ethane

—

Ethyl Alcohol

—

Ethyl Cellulose

—

Ethylene

—

Eu

✓

Eye Lens Icrp

—

F

—

Ferric Oxide

—

Ferroboride

—

Ferrous Oxide

—

Ferrous Sulfate

—

Fr

—

Freon-12

—

Freon-12B2

—

Freon-13

—

Freon-13B1

—

Freon-13I1

—

Gadolinium Oxysulfide

—

Galactic

—

Gallium

✓

Gallium Arsenide

—

Gd

✓

Ge

✓

Gel Photo Emulsion

—

Glass Lead

—

Glass Plate

—

Glutamine

—

Glycerol

—

Gold

✓

Graphite

—

Graphite Porous

—

Guanine

—

Gypsum

—

H

—

Hafnium

✓

He

—

Hg

✓

Ho

✓

I

✓

Indium

✓

Ir

✓

Iron

✓

K

✓

Kapton

—

Kevlar

—

Kr

✓

La

✓

Lanthanum Oxybromide

—

Lanthanum Oxysulfide

—

Lar

—

Lbr

—

Lead

✓

Lead Oxide

—

Lh2

—

Li

✓

Lithium Amide

—

Lithium Carbonate

—

Lithium Fluoride

—

Lithium Hydride

—

Lithium Iodide

—

Lithium Oxide

—

Lithium Tetraborate

—

Lkr

—

Ln2

—

Lo2

—

Lpropane

—

Lu

✓

Lucite

—

Lung Icrp

—

Lxe

—

M3 Wax

—

Magnesium

✓

Magnesium Carbonate

—

Magnesium Fluoride

—

Magnesium Oxide

—

Magnesium Tetraborate

—

Manganese

✓

Mercuric Iodide

—

Methane

—

Methanol

—

Mix D Wax

—

Molybdenum

✓

Ms20 Tissue

—

Muscle Skeletal Icrp

—

Muscle Striated Icru

—

Muscle With Sucrose

—

Muscle Without Sucrose

—

Mylar

—

N

—

N,N-Dimethyl Formamide

—

N-Butyl Alcohol

—

N-Heptane

—

N-Hexane

—

N-Pentane

—

N-Propyl Alcohol

—

Na

✓

Naphthalene

—

Nd

✓

Ne

✓

Neoprene

—

Nickel

✓

Niobium

✓

Nitrobenzene

—

Nitrous Oxide

—

Np

✓

Nylon-11 Rilsan

—

Nylon-6-10

—

Nylon-6-6

—

Nylon-8062

—

O

—

Octadecanol

—

Octane

—

Os

✓

P

✓

Pa

✓

Palladium

✓

Paraffin

—

Pbwo4

—

Phosphoric Acid

—

Photo Emulsion

—

Plastic Sc Vinyltoluene

—

Platinum

✓

Plexiglass

—

Plutonium Dioxide

—

Pm

✓

Po

✓

Polyacrylonitrile

—

Polycarbonate

—

Polychlorostyrene

—

Polyethylene

—

Polyoxymethylene

—

Polypropylene

—

Polystyrene

—

Polytrifluorochloroethylene

—

Polyvinyl Acetate

—

Polyvinyl Alcohol

—

Polyvinyl Butyral

—

Polyvinyl Chloride

—

Polyvinyl Pyrrolidone

—

Polyvinylidene Chloride

—

Polyvinylidene Fluoride

—

Potassium Iodide

—

Potassium Oxide

—

Pr

✓

Propane

—

Pu

✓

Pyrex Glass

—

Pyridine

—

Ra

✓

Rb

✓

Re

✓

Rh

✓

Rn

—

Ru

✓

Rubber Butyl

—

Rubber Natural

—

Rubber Neoprene

—

S

—

Sb

✓

Sc

✓

Se

✓

Si

✓

Silicon Dioxide

—

Silver

✓

Silver Bromide

—

Silver Chloride

—

Silver Halides

—

Silver Iodide

—

Skin Icrp

—

Sm

✓

Sodium Carbonate

—

Sodium Iodide

—

Sodium Monoxide

—

Sodium Nitrate

—

Sr

✓

Stainless-Steel

—

Stilbene

—

Sucrose

—

Tantalum

✓

Tb

✓

Tc

✓

Te

✓

Teflon

—

Terphenyl

—

Testis Icrp

—

Tetrachloroethylene

—

Th

✓

Thallium Chloride

—

Thymine

—

Tin

✓

Tissue Soft Icrp

—

Tissue Soft Icru-4

—

Tissue-Methane

—

Tissue-Propane

—

Titanium

✓

Titanium Dioxide

—

Tl

✓

Tm

✓

Toluene

—

Trichloroethylene

—

Triethyl Phosphate

—

Tungsten

✓

Tungsten Hexafluoride

—

U

✓

Uracil

—

Uranium Dicarbide

—

Uranium Monocarbide

—

Uranium Oxide

—

Urea

—

Valine

—

Vanadium

✓

Viton

—

Water

—

Water Vapor

—

Xe

✓

Xylene

—

Y

✓

Yb

✓

Zinc

✓

Zirconium

✓

6 of 6 entries include positron-lifetime components. A dash indicates that this entry supplies composition only.

Entry

Lifetime data

Aluminium

✓

Gold

✓

Kapton

✓

Lead

✓

Nickel

✓

Silver

✓

Entry

Density (g/cm³)

Aluminium

2.699

Gold

19.32

Lead

11.35

Nickel

8.902

Silver

10.5

Build from source

On Windows x64 with Python 3.12, Node.js/npm, CMake and Visual Studio 2022 C++ tools, run this from the repository root.

.\scripts\build-workbench.ps1
.\Start-TwinPALS.cmd

Both factory tables are included. The source build fetches the pinned Geant4 SDK and physics data once and caches them. The portable application already includes its runtime and datasets. Build steps, tests and portable packaging

Directory

Start here

backend/

Desktop launcher, local API, catalogue and module processing

backend/mcp_server/

MCP tools, persistent studies and the observer service

frontend/src/

React workbench, plots and observer

native/

Geant4 worker, pulse processing libraries and Windows tray

seed/ and third_party/geant4/

Factory catalogue, material definitions and Geant4 dependency manifest

tests/ and frontend/tests/

Python and frontend checks

Original TwinPALS code is MIT-licensed. Catalogue entries record their sources. The bundled G4EMLOW data are for non-commercial use within Geant4. This product includes software developed by Members of the Geant4 Collaboration (http://cern.ch/geant4). Notices · Scientific basis and citation

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • F
      license
      Not graded
      quality
      B
      maintenance
      Enables agents to discover available Mu2e analyses and run them on art files, returning parsed physics metrics and job results.
      -
    • A
      license
      A
      quality
      C
      maintenance
      Enables MCP clients to control the local Open Science research application, including creating projects, starting or continuing research sessions, inspecting progress and plans, canceling runs, and reading generated artifacts.
      12
      Apache 2.0
    • A
      license
      B
      quality
      B
      maintenance
      Enables any MCP client to plan and run verifiable analysis of engine hot-fire and bench test data through tools that open runs, segment phases, check sensor health, redlines, valve response and oscillations, compare simulations, verify every reported number against an evidence ledger, and write HTML reports. All findings stay traceable and reproducible from deterministic tool calls rather than raw samples.
      5
      24 PyPI
      MIT