Skip to main content
Glama
SphereAudio MCP Server

SphereAudio MCP Server

by devenu85

calibrate_speaker

Generate calibration WAVs or measure room-mic recordings to compute custom OcclusionProfile EQ curves for under-seat, perforated-riser, under-bed, or open-air speakers.

Instructions

Physical speaker calibration wizard: generate pink-noise/log-sweep calibration WAVs for under_seat, perforated_riser, or under_bed speakers (mode='generate'), or measure a recorded room-mic WAV to compute a custom OcclusionProfile EQ curve (mode='measure').

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "mode": "<mode>"
    },
    "name": "calibrate_speaker"
  }
}

Input Schema

NameRequiredDescriptionDefault
modeYesgenerate
targetNounder_seat
duration_sNo
rig_presetNoOptional rig preset for multi-channel calibration WAV generation
output_pathNoOutput WAV path (mode='generate') or optional JSON report path (mode='measure')
sample_rateNo
signal_typeNosweep
recorded_wavNoPath to recorded room microphone WAV (required for mode='measure')
material_nameNoOptional custom OcclusionProfile material name
reference_wavNoOptional reference stimulus or open-air recording WAV (mode='measure')

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv2.0.0

TDQS

B3.4/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden, and it does disclose the two distinct output artifacts (calibration WAV files and a computed OcclusionProfile curve), which is real behavioral value. It says nothing about filesystem side effects such as overwriting an existing file at output_path, how long generation takes, or what the measure mode actually returns or writes.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

It is a single dense sentence with no filler — every clause carries information about either mode or the artifacts produced. The nested parentheses make it harder to scan than a two-bullet mode breakdown would, but nothing is wasted.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 10-parameter, two-mode tool with no annotations and no output schema, the description covers the mode split and primary artifacts but leaves the measure-mode workflow underspecified — the roles of reference_wav and material_name, and what the JSON report contains, are not explained. It is adequate to start an invocation but not to predict outcomes confidently.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 50% across 10 parameters, so the description should compensate more than it does. It clarifies mode, three of the four target values (omitting 'open_air'), two of the three signal types (omitting 'combo'), and the role of recorded_wav, but duration_s, sample_rate, rig_preset, and reference_wav are left entirely to the schema.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a concrete resource ('Physical speaker calibration wizard') and splits it into two explicit operations: generating pink-noise/log-sweep WAVs and measuring a room-mic recording into an OcclusionProfile EQ curve. That is far more specific than the bare name, but it offers no routing against the sibling 'analyze_speaker_gains', which an agent could plausibly confuse with the measure mode.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage is implied through the mode breakdown — use 'generate' to produce stimuli, use 'measure' to derive an EQ curve from a recording — and the recorded-WAV prerequisite for measure mode is at least hinted at. There is no statement of when to prefer this over sibling tools, no prerequisite/permission context, and no mention of when measurement would be inappropriate.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.