radpareto-mcp
by callmesobhan
README.md
# `radpareto-engine`
**Closed-Loop AAPM TG-233 Task-Based Image Quality × Organ & Peak-Skin-Dose Pareto Protocol Optimization Engine with Frontier Agent Harness & MCP Server**
[](https://www.python.org/)
[](LICENSE)
[](NOTICE)
[](DATA_SOURCES_AND_CITATIONS.md)
[-E69F00?style=flat-square)](src/radpareto_engine/harness/mcp_server.py)
[](docs/AUDIT_REPORT.md)
[](pyproject.toml)
> **RESEARCH SOFTWARE NOTICE — NOT A MEDICAL DEVICE.** `radpareto-engine` is provided exclusively for medical physics research, algorithm benchmarking, and phantom metrology education under the Apache-2.0 License. It has **not** been cleared or approved by the FDA, EU MDR, or any regulatory authority, and **must not** be used for clinical diagnosis, automated scanner exposure control, or unverified clinical dose reporting without Qualified Medical Physicist (QMP) commissioning.
---
## Why `radpareto-engine`?
Consumer AI chat interfaces cannot ingest binary DICOM phantoms or DICOM Radiation Dose Structured Reports (RDSR), verify discrete Parseval noise-power conservation, ray-cast multi-angle C-arm fluoroscopy beams onto 3D patient entrance skin, or enforce real X-ray tube current/power/heat saturation ceilings while solving exact inverse Dose–Detectability frontiers.
`radpareto-engine` solves this end-to-end with strictly typed **Pydantic v2** Physics IR, **cryptographic SHA-256 provenance**, **5 hard `AbstentionCode` safety gates**, an autonomous **Critic-Verifier Agent Harness**, and a zero-bloat **JSON-RPC 2.0 stdio MCP server**.
---
## System Architecture
```mermaid
flowchart TD
A["DICOM CT / Phantom & RDSR Input (pydicom)"] --> B["AAPM TG-233 Metrology Kernel (TTF, 2D/3D NPS, Parseval, NPWE & CHO d')"]
A --> C["Dosimetry & RDSR Engine (TG-204/220/293 SSDE, ATCM, 3D Fluoro PSD)"]
B --> D["Multi-Vendor Pareto & Inverse d' Solver (Siemens / GE / Philips / Canon)"]
C --> D
E["X-Ray Tube Hardware Limits (mA, kW, MHU, Sn-Filter)"] --> D
D --> F["Hard Abstention & Provenance Layer (SHA-256 + 5 AbstentionCode Gates)"]
D --> G["Saltelli-Jansen QMC Sobol' UQ (S_1, S_T, 95% CI)"]
F --> H["Frontier Agent Orchestrator & Independent Critic-Verifier Gate"]
G --> H
H --> I["ACR / AAPM TG-233 Physics Audit Dossier (Markdown + JSON)"]
H --> J["JSON-RPC 2.0 Stdio MCP Server (6 Provenance-Gated Tools)"]
```
---
## Verified Benchmark & Independent Audit Dashboard
All metrics below are deterministically reproduced by `scripts/run_benchmarks_and_figures.py` and independently verified by `scripts/run_independent_audit.py` (see [`docs/AUDIT_REPORT.md`](docs/AUDIT_REPORT.md)).
| Benchmark / Verification Domain | Metric | Verified Result | Reference / Gate |
|---|---|---|---|
| **AAPM TG-233 Parseval Invariant** | Max discrete 2D NPS integral vs. variance error ($n=12$) | **`2.93e-16`** | Tolerance `< 0.02` (`PARSEVAL_NPS_VIOLATION`) |
| **Closed-Form $d'$ Scaling** | Max error for $d'(2C)=2d'(C)$ and $d'(4\cdot\mathrm{NPS})=0.5\,d'$ | **`2.02e-16`** | Exact quantum-limited NPWE identity |
| **Nonlinear IR Resolution Shift** | MBIR $f_{50}$ High (+500 HU) vs. Low (+45 HU) contrast | **`0.42 → 0.34 mm⁻¹`** | AAPM TG-233 contrast-dependent TTF |
| **Iodine CTA Spectral Pareto** | 2 mm vessel ($d'=6.0$, $D_w=27\text{ cm}$): `80 kVp DLR` vs `140 kVp FBP` | **`1.71 vs. 18.20 mGy`** | `-90.6%` exact inverse CTDIvol solve |
| **3D Fluoroscopy PSD (RDSR)** | 6-event CTO-PCI RDSR round-trip Peak Skin Dose | **`6.22 Gy`** (`53 cm² > 5 Gy`) | NCRP 168 / ICRP 120 `FOLLOWUP_5GY` tier |
| **Multi-Vendor Fleet Drift Audit** | 6-scanner fleet (Siemens, GE, Philips, Canon) | **`-41.5%` mean CTDIvol** | Compliance `3/6 → 6/6`; **6/6 Critic-Verifier APPROVED** |
| **Saltelli–Jansen Sobol' UQ** | Analytical Ishigami accuracy ($N_{\text{base}}=1024$) | **Max err `0.0124`** | Saltelli 2010 / Jansen 1999 QMC |
| **Public Open-License CT Sample** | `data/public_ct_sample/CT_small.dcm` (MIT) | **$D_w = 8.72\text{ cm}$** | SHA-256 verified against `MANIFEST.json` |
| **Hard Safety Abstention Gates** | Adversarial trigger suite across all 5 `AbstentionCode`s | **`5 / 5` FIRED** | Zero silent bypasses |
| **3D Volumetric NPS Parseval** | Full 3D FFT $\mathrm{NPS}_{3D}(f_x, f_y, f_z)$ variance check | **`< 1e-15`** | Exact 3D Parseval conservation |
| **Empirical Scanner Calibration** | Phantom-to-surrogate regression fit ($n=6$ scans) | **$R^2_{\text{noise}} = 1.000$, $R^2_{f_{50}} = 0.992$** | RMS $d'$ error `0.31` |
| **Joint Multi-Task Pareto & VMI** | Simultaneous Liver + CTA compliance & PCCT VMI UHR | **`6.68 mGy`** joint min; **PCCT 40 keV $d'=21.0$** | Binding-task guardrail + K-edge peak |
| **Longitudinal ATCM & QA CUSUM** | $z$-axis ATCM DLP savings & 30-session SQLite CUSUM | **`-44.8%` DLP**; **Alert at Session 20** | Tube aging onset at Session 18 caught in 2 runs |
| **Multi-Procedure Cranial PSD** | 3 staged neuro-angiography runs (120-day window) | **`15.8 Gy`** strict vs. **`12.7 Gy`** repair-weighted | TJC $\ge 15\text{ Gy}$ sentinel gate |
---
## Publication-Grade Visuals (300-DPI PNG & Vector PDF)
All 6 figures follow *Medical Physics* / *Radiology* styling with the colorblind-safe Okabe–Ito palette, physical scalebars, bold panel labels, and cryptographic SHA-256 provenance footers.
### 1. AAPM TG-233 Nonlinear Phantom Metrology (TTF, 2D/1D NPS, NPWE & CHO $d'$)

### 2. Habitus-Stratified Dose–Detectability Pareto Frontiers & Tube Saturation Boundary

### 3. 3D Patient-Surface Fluoroscopy Peak Skin Dose (PSD) Map from DICOM RDSR

### 4. Autonomous Multi-Vendor Fleet Protocol Drift Audit & Critic-Verifier Gate

### 5. Saltelli–Jansen Global Sobol' Sensitivity & 2D ($D_w \times \text{CTDI}_{\text{vol}}$) Phase Diagram

### 6. Public Open-License CT Calibration, Multi-Habitus SSDE & Formal Invariant Verification

### 7. Empirical Scanner Calibration, Joint Multi-Task Pareto & PCCT/DECT Spectral VMI (`v0.2.0`)

### 8. Longitudinal SQLite TG-233 QA CUSUM Drift Monitor & Multi-Procedure Cranial PSD (`v0.2.0`)

---
## Quickstart (`uv` + Python 3.12)
```bash
# 1. Install package and dev tools with uv
uv sync --extra dev --python 3.12
# 2. Verify public MIT CT sample + SHA-256 manifest
uv run python scripts/fetch_public_ct_sample.py
# 3. Unified CLI (`radpareto`) quick runs
uv run radpareto tg233 --recon hybrid_ir --ctdi 10
uv run radpareto pareto --dw 29 --multitask
uv run radpareto psd results/benchmark_cto_pci_rdsr.dcm --geometry torso
uv run radpareto audit
uv run radpareto qa-check --sessions 30 --drift-onset 18
# 4. Run full test suite (strict warnings + Hypothesis fuzzing) & lint
uv run pytest --cov=radpareto_engine --cov-report=term-missing
uv run ruff check src tests scripts
# 5. Reproduce all 8 publication figures & 14-check independent audit
uv run python scripts/run_benchmarks_and_figures.py
uv run python scripts/run_independent_audit.py
```
---
## Collapsible Workflows (Python API & MCP Server)
<details>
<summary><strong>Python API: Exact Inverse Minimum-Dose Solve & Multi-Vendor Fleet Audit</strong></summary>
```python
from radpareto_engine.ir import ClinicalTaskSpec, CTProtocolSpec, CTVendor, ReconMode
from radpareto_engine.pareto_optimizer import invert_min_dose_for_dprime
from radpareto_engine.harness.agent_orchestrator import audit_and_optimize_protocol_fleet
protocol = CTProtocolSpec(
protocol_id="ABD-HYBRID-IR",
scanner_name="Siemens SOMATOM Force",
vendor=CTVendor.SIEMENS,
kvp=100.0,
slice_thickness_mm=3.0,
recon_mode=ReconMode.HYBRID_IR,
ir_strength=0.6,
)
task = ClinicalTaskSpec(
name="5mm_low_contrast_liver_lesion",
diameter_mm=5.0,
contrast_hu=25.0,
d_prime_target=3.0,
)
# Exact minimum CTDIvol required to guarantee d' >= 3.0 at D_w = 31 cm
sol = invert_min_dose_for_dprime(protocol=protocol, d_w_cm=31.0, task=task)
print(f"Min CTDIvol = {sol.min_ctdi_vol_mgy:.2f} mGy | SSDE = {sol.min_ssde_mgy:.2f} mGy | d' = {sol.achieved_d_prime:.2f}")
# Autonomous multi-vendor fleet audit + Critic-Verifier Gate
dossier = audit_and_optimize_protocol_fleet()
print(f"Critic approved: {dossier.critic_approved_count}/{dossier.total_protocols} | Mean CTDI delta: {-dossier.fleet_mean_ctdi_reduction_pct:+.1f}%")
```
</details>
<details>
<summary><strong>MCP Server (JSON-RPC 2.0 stdio): 8 Provenance-Gated Physics Tools</strong></summary>
Start the zero-bloat stdio MCP server:
```bash
uv run radpareto-mcp # or: uv run radpareto mcp
```
Exposed tools (`tools/list`):
1. `radpareto_measure_tg233` — Circular-edge TTF, 2D/3D Parseval-verified NPS, NPWE & CHO $d'$.
2. `radpareto_compute_ssde_and_psd` — AAPM TG-204/220/293 SSDE + calibrated 3D fluoroscopy PSD.
3. `radpareto_solve_pareto_frontier` — Hardware-constrained CT Dose–Detectability Pareto frontier.
4. `radpareto_invert_min_dose_for_dprime` — Exact Brent inverse solve for minimum $\text{CTDI}_{\text{vol}}$ guaranteeing $d' \ge d'_{\text{target}}$.
5. `radpareto_audit_protocol_fleet` — Multi-vendor drift audit + Critic-Verifier Gate dossier.
6. `radpareto_run_sobol_sensitivity` — Saltelli–Jansen QMC global Sobol' sensitivity ($S_1, S_T, 95\%\text{ CI}$).
7. `radpareto_solve_multitask_pareto` — Joint multi-task Pareto optimization (Liver + CTA) with optional PCCT/DECT VMI sweep.
8. `radpareto_analyze_dicom_file` — Real local CT Image (`.dcm`) or DICOM RDSR (`.dcm`) analysis with SHA-256 provenance.
Example JSON-RPC 2.0 call:
```json
{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"radpareto_invert_min_dose_for_dprime","arguments":{"d_w_cm":30.0,"d_prime_target":3.0,"kvp":120,"recon_mode":"hybrid_ir","ir_strength":0.6}}}
```
Hard safety violations (e.g., uncalibrated RDSR or tube saturation) return structured MCP responses with `"isError": true` and machine-readable `"abstention_code"`.
</details>
---
## Documentation, Citations & License
- **Technical Specification:** [`docs/ENGINE_SPECIFICATION.md`](docs/ENGINE_SPECIFICATION.md)
- **Independent Audit Report:** [`docs/AUDIT_REPORT.md`](docs/AUDIT_REPORT.md)
- **Data Sources, Verified DOIs & BibTeX:** [`DATA_SOURCES_AND_CITATIONS.md`](DATA_SOURCES_AND_CITATIONS.md)
- **Citation Metadata:** [`CITATION.cff`](CITATION.cff)
- **License & Research Notice:** [`LICENSE`](LICENSE) (Apache-2.0) and [`NOTICE`](NOTICE)
This server cannot be deployed