NameDescription
quantnuc_forward_nema_rcC

Simulate 3D NEMA NU 2-2018 6-sphere Recovery Coefficients (RCmean, RCmax, RCpeak) including PSF-Gibbs ringing.

quantnuc_invert_pve_activityC

Invert true lesion activity from observed SUV using Rousset GTM, Muller-Gartner, or Bayesian PVC with p05/nominal/p95 CI.

quantnuc_synthesize_earl_filterC

Synthesize minimal post-reconstruction Gaussian/Butterworth harmonization filter for EARL1, EARL2, QIBA, or MIRD23_SPECT.

quantnuc_audit_ct_ac_mismatchC

Compute exact CT-PET/SPECT respiratory attenuation-correction line-integral bias exp(int delta_mu ds) and abstention status.

quantnuc_diagnose_suv_shiftC

Decompose a longitudinal delta-SUV shift into PSF-Gibbs, PVE resolution, CT-AC respiratory artifact, and true biological change.

quantnuc_run_sobol_sensitivityC

Run Saltelli-Jansen QMC global Sobol' sensitivity analysis (S1, ST, interactions) on quantitative SUV variance.

quantnuc_compute_theranostic_doseC

Propagate Rousset GTM partial-volume recovery into MIRD-23/26 multi-timepoint tumor absorbed dose (Gy) with 90% uncertainty interval.

quantnuc_audit_3d_ct_ac_volumeC

Compute 3D bilinear HU-to-mu(E) ray-traced CT-AC respiratory mismatch bias across a lung-liver dome volume.

quantnuc_generate_physics_dossierC

Run the end-to-end Frontier Agent Forensics Physicist (4-scanner EARL2/MIRD-23 harmonization, longitudinal attribution, Critic-Verifier Audit).

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3/5.0

Scored across 9 tools

Disambiguation4/5

Each tool maps to a distinct computational step (forward RC simulation, inverse PVC, filter synthesis, CT-AC bias, SUV decomposition, Sobol, dosimetry, dossier), but `quantnuc_audit_ct_ac_mismatch` and `quantnuc_audit_3d_ct_ac_volume` are close cousins distinguished only by 'line-integral' vs '3D ray-traced volume', and the end-to-end dossier overlaps conceptually with chaining the individual tools. Descriptions do resolve the ambiguity for a careful agent.

Naming Consistency4/5

All tools share a `quantnuc_` prefix plus snake_case verb_noun structure (invert_pve_activity, synthesize_earl_filter, compute_theranostic_dose), which is predictable. Minor deviations: `quantnuc_forward_nema_rc` uses 'forward' as a verb and several names are heavy abbreviation strings (nema_rc, ct_ac, suv_shift) that read more like jargon than a clean pattern.

Tool Count5/5

Nine tools is well within the sweet spot and each corresponds to a real, non-redundant step in the quantitative nuclear-medicine workflow. The dossier tool acts as an orchestrator rather than an inflated duplicate, so nothing feels padded.

Completeness4/5

The surface covers the domain lifecycle end to end: forward simulation, inversion/PVC, harmonization filter synthesis, CT-AC auditing (2D and 3D), longitudinal attribution, global sensitivity, and dosimetry with uncertainty plus a final dossier. Gaps are minor—no way to enumerate/validate supported scanners, phantoms, or reconstruction protocols, and no plotting/export of intermediate results for inspection.