Skip to main content
Glama
brayangcastro

industrial-mcp

README.md
# industrial-mcp

> An MCP server that gives Claude (or any MCP-compatible AI host) read
> access to industrial sensor data and **safety-gated** control over
> motors and actuators.

The hard part of *Physical AI* isn't getting a language model to talk
about a factory — it's getting it to **act** on one without anyone
losing sleep. That requires three boring things working together:

1. **Tool schemas** the model can understand and call correctly.
2. **Safety preconditions** that block dangerous actions even when the
   model is confident.
3. **An audit trail** that survives the next post-mortem.

This repo is a working implementation of all three, in under 500 lines
of Python, using [FastMCP][fastmcp]. Default mode is read-only and
ships with a deterministic mock adapter modeling a 7-silo grain
storage facility, so it runs in CI with no infrastructure.

The read path is **verified end to end against real hardware**: an
ESP32-S3 with DS18B20 probes on a OneWire mux, answering a model's
questions about grain temperature over the LAN. Warming one probe by
hand moved `max_temp_c` from 28.0 to 31.0 — and dropped the *average*,
because the other probe was in cold water. That measurement is why
these tools return `min`, `max`, and `faulted_sensors` instead of one
reassuring number. Evidence, including what is **not** verified:
[`docs/hardware-verification.md`](docs/hardware-verification.md)
([español](docs/verificacion-hardware.md)).

[fastmcp]: https://github.com/modelcontextprotocol/python-sdk

---

## Architecture

```text
┌─────────────────────────────────────────────────────────────────────┐
│  MCP host  (Claude Desktop, Claude Code, Cursor, etc.)              │
│   user prompt ──► model decides which tool to call                  │
└──────────────────────────────┬──────────────────────────────────────┘
                               │  stdio  (JSON-RPC over MCP)
                               ▼
┌─────────────────────────────────────────────────────────────────────┐
│  industrial-mcp  (this repo)                                        │
│                                                                     │
│   server.py ── wires tools, env config, audit log                   │
│      │                                                              │
│      ├── tools.py ── 5 read tools + 1 write tool (dry-run default)  │
│      │                                                              │
│      ├── safety.py ── preconditions, advisory warnings              │
│      │                                                              │
│      ├── audit.py ── append-only JSONL of executed actions          │
│      │                                                              │
│      └── adapters/                                                  │
│            ├── base.py    ← PlantAdapter protocol (the contract)    │
│            ├── mock.py    ← default, deterministic demo data        │
│            └── esp32.py   ← HTTP to a live SiloScan module          │
└──────────────────────────────┬──────────────────────────────────────┘
                               │
            ┌──────────────────┼──────────────────┐
            ▼                  ▼                  ▼
   [MQTT broker]      [internal REST API]   [historian / TSDB]
```

---

## Quick start

Run the server, talk to it from Claude Desktop, see it work.

```bash
# 1. Run the server with the mock adapter (no infra required)
uvx industrial-mcp@latest

# 2. Add this to ~/Library/Application Support/Claude/claude_desktop_config.json
#    (macOS) — see examples/claude-desktop-config.json
```

Then in Claude Desktop:

> *¿Qué silos tienen alerta crítica hoy?*

Claude calls `list_plants` → `get_active_alerts` → answers with the
data. See [`examples/demo-transcript.md`](examples/demo-transcript.md)
for a full session.

To enable live (non-dry-run) execution against the mock adapter:

```bash
INDUSTRIAL_MCP_ALLOW_WRITES=true uvx industrial-mcp@latest
```

This flag does **not** affect dry runs — those always work. It only
unlocks the path where a tool call would actually mutate state.

---

## Tools exposed over MCP

| Tool | Type | Purpose |
| --- | --- | --- |
| `list_plants` | read | List facilities the server can see. |
| `list_silos` | read | Silos at a plant with capacity in tons. |
| `get_silo_thermometry` | read | Latest thermometry snapshot (min/avg/max °C). |
| `list_motors` | read | Motors at a plant, optionally filtered by kind. |
| `get_active_alerts` | read | Active alerts, filterable by severity. |
| `scan_devices` | read | Find modules on the LAN when one stopped answering. Never writes config. |
| `trigger_motor_action` | **write** | Start/stop a motor — dry-run by default, safety-gated, audited. |

Tool schemas live in [`src/industrial_mcp/tools.py`](src/industrial_mcp/tools.py).
Keep their docstrings short and exact — they become the model's tool
descriptions.

---

## Why three layers of safety, not one

`trigger_motor_action` will only execute when **all** of the following
hold:

1. The LLM explicitly sets `dry_run=False`.
2. The call includes an `operator_id` and a `reason`.
3. The server itself was started with `INDUSTRIAL_MCP_ALLOW_WRITES=true`.
4. Every precondition in `safety.evaluate_motor_action` passes.

Step 3 is the one that matters most. The model can hallucinate
`dry_run=False`; the operator field can be spoofed by a clever prompt;
the safety check can have a bug. But if the server was started
read-only, **none of that touches a motor**. The deploy posture is the
last word, not the prompt.

Every executed call is appended to an append-only JSONL audit log:

```json
{"ts": 1779600000.12, "actor": "op-42", "action": "motor.start",
 "target": "fan-7-1", "outcome": "applied",
 "details": {"reason": "silo-7 at 32.1°C, manual fan-on"}}
```

Dry runs are not logged. They're not interesting and they'd dilute
the signal.

---

## Adapters

The contract every adapter must satisfy lives in
`src/industrial_mcp/adapters/base.py` as a `PlantAdapter` Protocol —
`list_plants`, `list_silos`, `get_silo_thermometry`, `list_motors`,
`get_motor`, `get_plant_context`, `get_active_alerts`,
`apply_motor_action`. Motor records must carry `plant_id`; the tool
layer resolves plant context from the motor rather than from a
constant, so a motor without one is refused instead of evaluated
against the wrong plant.

`INDUSTRIAL_MCP_ADAPTER` selects which one runs. It knows `mock`
(deterministic, shipped, used by CI) and `esp32` (HTTP to a live
SiloScan thermometry module). An unrecognized name raises at startup —
the server never falls back to the mock, because answering questions
about a plant you are not connected to is worse than refusing to start.

```bash
INDUSTRIAL_MCP_ADAPTER=esp32 \
INDUSTRIAL_MCP_ESP32_HOST=banco-silo3.local \
INDUSTRIAL_MCP_ESP32_DEVICE_ID=banco-silo3 \
INDUSTRIAL_MCP_ESP32_CABLES=0,8 \
uv run industrial-mcp
```

`INDUSTRIAL_MCP_ESP32_CABLES` defaults to channel `0` alone — each
channel costs a OneWire conversion, so the default is cheap rather than
complete. Leaving it out silently drops every other probe.

**Use a name, not an address.** Firmware 0.5.0+ publishes
`<device_id>.local` over mDNS. DHCP will move the address out from under
any file you write it into — the bench module took three different
leases in three reboots, and every stale config in this repo's history
traces back to that.

`INDUSTRIAL_MCP_ESP32_DEVICE_ID` is optional and turns on self-healing:
when the configured host stops answering, the adapter looks the module
up by name, then by subnet sweep, and adopts the new address **only if
the device identifies itself as that id**. Without it the adapter
reports `device_unreachable` instead of guessing — a sweep cannot tell
"my module moved" from "some other module answered", and silo 3's tools
reading silo 7's sensors would produce numbers that look perfectly
reasonable and come from the wrong bin.

The `scan_devices` tool exposes the same sweep to the model, read-only:
it reports what answered and never edits configuration. Scanning is
restricted to private address space and to ranges of /22 or smaller.

Two things the `esp32` adapter does that are worth copying into your
own adapter, both of them about not laundering a sensor fault into a
plausible number:

- A reading counts only when the firmware classified it `valid` **and**
  the temperature is actually present. Averaging a missing reading as
  0 °C is how a hot silo reads cool.
- An unreachable module returns `{"error": "device_unreachable"}`, never
  an exception and never a stale number wearing a fresh timestamp. The
  timestamp comes from the machine doing the read, because the module's
  clock is only right after an NTP sync.

To talk to a different plant, drop a sibling module implementing the
Protocol and add its name to `build_adapter` in `server.py`.

---

## Development

```bash
git clone https://github.com/brayangcastro/mcp-industrial-agent
cd mcp-industrial-agent
uv sync --extra dev
uv run pytest -v
uv run ruff check src tests
```

CI runs the same two commands on Python 3.11 and 3.12 — see
[`.github/workflows/ci.yml`](.github/workflows/ci.yml).

---

## FAQ

**Why not just give the model raw API keys?**
Because then every prompt injection is one HTTP call away from a
production motor. The MCP surface is narrow on purpose: the model
sees six functions, not your AWS console.

**Why a separate `dry_run` flag instead of a confirmation step?**
Confirmation steps add latency and break flow. The dry run returns
the *outcome the model would have caused* — preconditions, warnings,
state delta — as data the model can keep reasoning over. Live
execution is then a one-line escalation, not a five-prompt dance.

**Is the audit log enough for compliance?**
No. It's enough to reconstruct *what happened*. It is not enough on
its own for IEC 62443, IATF 16949, or similar. Pair it with your
plant's existing change-management system; this repo is a starting
point, not a finished compliance story.

**Is this only a mock? Where's MQTT / OPC UA?**
No longer only a mock — the `esp32` adapter reads a live device over
HTTP, and the read path is verified against it. MQTT and OPC UA are
still absent, and they are usually plant-specific anyway: the broker
URLs, topic structures, and ACLs you can publish publicly are usually
zero. The `PlantAdapter` Protocol is the extension point.

**So the safety gate is proven against real equipment?**
Against a real **pin**, yes. Firmware 0.4.0 exposes `/api/relay`, and
the four-step escalation was run against it: dry run left the pin low,
a call without `operator_id` was rejected with the pin low, a read-only
server rejected it with the pin low, and only the fourth call drove it
high. Be precise about the limit, though — that is a logic-level GPIO
with an LED on it, not a three-phase fan with inrush current and
interlocks. What was proven is that the gate stops a real actuator from
moving; motor sequencing is a different problem.

**How do you know the relay actually switched?**
Because the module is asked, not trusted. `GET /api/relay` reports the
level read back off the pad next to the command it was given, and
`apply_motor_action` decides success from the reading. A 200 response
with the pin still low comes back as a fault. An actuator that only
repeats the order it was given is not telemetry, it is an echo.

---

## Status

Read and write paths both verified against hardware. Not 1.0 — the
shapes are stable, but expect breaking changes in non-public APIs.

| Area | State |
| --- | --- |
| `mock` adapter | Shipped, deterministic, used by CI |
| `esp32` adapter, read path | **Verified against a live module** — [evidence](docs/hardware-verification.md) |
| Safety gate + audit log | **Verified against a physical pin** — dry run and both rejections left it low |
| Actuator fault detection (`mismatch`) | **Triggered on hardware** — feedback wire pulled; safety refused with every gate open |
| Real motor (inrush, interlocks) | Not attempted — the verified actuator is a GPIO pair with an LED |
| MQTT / OPC UA adapters | Not started |

## Author

Built and maintained by [Brayan Castro](https://ingebc.com) — Ing.
Mecatrónica (ITESM Sonora Norte), operating BC Ingeniería from Guasave,
Sinaloa. Background: 4+ years building IoT systems for agroindustrial
grain handling (firmware ESP32 + thermocouple MUX + cloud), backend
services for property management and POS, and conversational AI agents
on top of Claude / GPT-4o. Reach out: `info@ingebc.com`.

## License

MIT — see [LICENSE](LICENSE).

TDQS

A4/5.0

Scored across 6 tools

Disambiguation5/5

Each tool targets a distinct resource and action: plants, silos, thermometry, motors, alerts, and motor actions. The only possible overlap is between list_silos and get_silo_thermometry, but one lists silos and the other retrieves data for a specific silo, so there is no ambiguity.

Naming Consistency5/5

All tool names follow a consistent verb_noun pattern: list_plants, list_silos, list_motors, get_active_alerts, get_silo_thermometry, trigger_motor_action. The verbs are clear and the style is uniformly snake_case, making the set predictable and easy to navigate.

Tool Count5/5

With 6 tools, the server is well-scoped for industrial monitoring and control. Each tool serves a clear purpose without excessive overlap or unnecessary additions, and the count is neither too thin nor too heavy for the domain.

Completeness4/5

The tool set covers the core workflows: listing assets, retrieving detailed sensor data, checking alerts, and issuing motor control commands with safety checks. Minor gaps exist, such as no dedicated tool for getting a single motor's detailed status or acknowledging alerts, but these do not critically hinder agent operations.

Maintenance

ActivityMaintained