Skip to main content
Glama
cadcraft-electrical-mcp

cadcraft-electrical-mcp

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault

No arguments

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

Industrial electrical drawings (IEC 81346/60617/61082/60204-1 or NFPA 79) generated as DXF and published through CADCraft (PDF, PNG, DWG).

Workflow:

  1. project_create (or project_open). Pick profile iec | iec_legacy | nfpa.

  2. library_search -> device_add (catalog_id or kind; tags auto-assigned per profile). Vendor 2D models: library_import_model (DXF/DWG front view -> clean 1:1 block).

  3. potential_set for extra rails; sheet_add power/control sheets with current paths.

  4. plc_io_assign + sheet_add(kind=plc_io, plc=...); terminals_assign_io for field wiring.

  5. network_link + sheet_add(kind=network).

  6. cabinet_configure (+ cabinet_rails / cabinet_place) -> cabinet_plan.

  7. validate -> build(previews=[...]) -> sheet_preview(n) to visually check -> fix -> rebuild.

  8. cadcraft_open to show the result in the CADCraft desktop app. All changes are saved immediately in .elec.yaml (source of truth). Reply to the user in Spanish.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": false
}
prompts
{
  "listChanged": false
}
resources
{
  "subscribe": false,
  "listChanged": false
}

Tools

Functions exposed to the LLM to take actions

NameDescription
project_createB

Create a new electrical project and make it the active one.

profile: 'iec' (IEC 81346-2:2019 two-letter codes, vertical paths, A3), 'iec_legacy' (single-letter -K/-F/-Q codes) or 'nfpa' (NFPA 79 ladder, ANSI B). Standard potentials L1 L2 L3 N PE 24V 0V are pre-declared. The project is saved as .elec.yaml in the workspace (or in directory).

project_openB

Open an existing project by code (from the workspace) or by the full path of its .elec.yaml.

project_listA

List the projects found in the workspace folder.

project_infoA

Summary of the active project: title-block data, counts, potentials, sheets, cabinet.

project_updateB

Update title-block fields and/or switch the standards profile (iec / iec_legacy / nfpa).

potential_setB

Declare a potential (rail): e.g. name='24V' kind='dc_plus', or 'L1_CTRL' kind='ac_control'.

The kind decides the conductor colour on drawings and lists.

standards_infoB

Rules of a standards profile: letter codes per device kind, wire colours, sheet format, text heights, terminal marking, available profiles and validation rules.

symbols_listB

Symbols available for current-path elements (use the id in PathElement.symbol).

library_searchB

Search the device catalog (built-in typical devices + your imported vendor models).

Example queries: 'S7-1200', 'balluff hub', 'mcb 2p', 'psu 24'.

library_import_modelA

Clean a vendor 2D model (DXF or DWG front view) into a 1:1 mm block and add it to your catalog.

Removes CADENAS ATTDEFs, connection points and (by default) dimensions, converts DWG through CADCraft, moves the lower-left corner to 0,0. Use target_width_mm (real device width) when the file is not drawn in mm. The cleaned DXF goes to /library.

device_addA

Add one or more devices. Give catalog_id (see library_search) or at least kind.

Tags are auto-assigned from the profile letter code when omitted (-QA1, -KF2 ... or CR1, M1 in NFPA). Use mount='field' for devices outside the cabinet, 'door' for door-mounted ones. A terminal_strip device also creates its (empty) strip.

device_updateC

Change device data. Renaming (new_tag) updates all references (sheets, I/O, network, cabinet).

device_removeA

Remove a device. Fails if it is referenced unless force=true (then references are removed too).

device_listB

List project devices (optionally of one kind).

sheet_addA

Add a sheet definition. Kinds:

  • power / control: list of current paths. Each path: supply rails (one per pole, e.g. ['L1','L2','L3'] or ['24V']), series elements [{device, symbol?, terminals?, label?}], optional return_rail ('0V', 'N') and pe. Symbols/terminals default from the device kind (coil A1-A2, contacts 13-14/21-22..., poles 1-2/3-4/5-6). Use symbol 'contact_no'/'contact_nc' to draw a relay/contactor contact; cross references are automatic. Long sheets paginate.

  • plc_io: plc tag (+ optional io_kinds); draws every channel assigned with plc_io_assign.

  • network: topology of all network links. * cover / terminal_plan / cabinet_layout: automatic.

sheet_add_pathsC

Append current paths to an existing power/control sheet.

sheet_updateC

Replace fields of a sheet (giving paths replaces all its paths).

sheet_removeC

Delete a sheet definition.

sheet_moveB

Move a sheet to a 1-based position in the set (cover stays first, terminal/cabinet sheets last).

sheet_getC

Full definition of one sheet.

plc_io_assignA

Assign PLC channels to field devices. Address (%I0.0, %Q0.0, %IW64) and module terminal (DIa.0, DQa.0 ... from the catalog) are auto-assigned when omitted; channel count is checked against the catalog.

plc_io_removeC

Remove one I/O channel assignment.

plc_io_listB

List I/O assignments (optionally of one PLC).

terminals_addA

Add terminals to a strip (created when missing; tag auto -XD1.. if omitted). Either count consecutive numbers or explicit numbers. Mark protective-earth terminals with pe=true.

terminals_assign_ioB

Route every field-mounted I/O device through its own terminal on strip (drawn on the I/O sheets and listed in the terminal plan).

terminals_listC

Terminal strips with their terminals.

terminals_removeB

Remove one terminal, e.g. '-XD2:5'.

network_linkB

Connect device ports: [{a_device, a_port, b_device, b_port, protocol: profinet|ethernet|iolink, cable?, length_m?}]. The network sheet draws them as a tree rooted at the PLC.

network_unlinkC

Remove the link(s) between two devices.

network_listC

List network links.

cabinet_configureB

Configure the enclosure and mounting plate (mm). Defaults: 400x500x250 enclosure, 350x450 plate, 40x60 wire ducts, 10 mm duct clearance, 20 % spare rail length.

cabinet_railsA

Fix which devices go on each DIN rail, top to bottom, left to right (e.g. [["-QB1","-FC1"], ["-KF1","-TB1"]]). An empty list returns to automatic filling.

cabinet_placeB

Place a device manually (lower-left corner, plate coordinates, mm). Omit x/y to return to auto.

cabinet_planA

Compute the back-plate layout without drawing: device positions, rails, fill %, warnings.

validateA

Check the project against the standards profile and consistency rules (designations, I/O, ports, terminals, cross references, cabinet fit/spare space ...).

buildA

Generate the drawing set: DXF (all sheets), multi-page PDF (via CADCraft), optional DWG, the 1:1 fabrication DXF of the back plate, XLSX/CSV lists and PNG previews of the sheet numbers in previews. Returns file paths, page list and a validation summary.

sheet_previewA

Render one sheet (1-based page number) to PNG with CADCraft and return the image to inspect.

reportsB

Export BOM, wire list, terminal list, PLC I/O list and network list to XLSX (+ CSV).

cadcraft_statusB

CADCraft installation, version and whether the desktop app control port is reachable.

cadcraft_openA

Open a file in the CADCraft desktop app (launches cadcraft --control <port> if needed). Without path: which='drawings' (sheet set DXF) or 'cabinet' (1:1 plate DXF) of the last build.

cadcraft_executeB

Escape hatch: run any CADCraft engine command in the running app (e.g. 'zoom', 'layer.set'). Needs the desktop app started with --control. Prefer the domain tools for drawing content.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3.1/5.0

Scored across 41 tools

Disambiguation4/5

Most tools have clearly distinct resource/action boundaries across projects, devices, sheets, I/O, terminals, network, cabinet, and library domains. There is some overlap between reports and build (both can emit XLSX/CSV lists), between sheet_add_paths and sheet_update, and between project_open and cadcraft_open, but descriptions mostly clarify the intended use.

Naming Consistency4/5

The dominant convention is a predictable resource_action pattern (device_add, project_create, sheet_remove, plc_io_assign, terminals_list, network_link, cabinet_plan). A few tools deviate with bare verbs or nouns (reports, build, validate) and the cadcraft_ namespace, but the overall scheme is readable and consistent.

Tool Count2/5

At 41 tools the surface is heavy for an MCP server, even for a broad electrical CAD domain. Many operations are genuinely distinct, but the count exceeds the 25-tool threshold and increases selection burden.

Completeness4/5

The surface covers the full engineering lifecycle: project/device/sheet CRUD, PLC I/O, terminals, networking, cabinet layout, validation, previews, reports, and build outputs. Only minor gaps exist, such as no project delete/archive, no potential listing/removal, and no dedicated device_get beyond device_list.

Maintenance

ActivityNo data
ResponsivenessOutdated data